Chapter 5 SONET Topologies
Bidirectional Line Switched Rings
When you perform a manual switch, a manual switch request equipment alarm (MANUAL-REQ) is
generated. This is normal.
Caution
Traffic is unprotected during a protection switch.
c.
Log into the node that is connected through its west port to the node where the trunk card will be
moved. (In the
example, this is Node 3.) Click the
Maintenance > Ring
tabs.
d.
From the West Switch list, choose
FORCE RING
. Click
Apply
.
Step 3
Log into the node where the trunk card you will move is installed.
Step 4
Click the
Circuits
tab
. Write down the circuit information or, from the File menu, select
or
Export
to print or export the information; you will need it to restore the circuits later. See the
“Printing and Exporting CTC Data” section on page 2-41
for more information.
Figure 5-15 Deleting circuits from a BLSR trunk card
Step 5
Delete the circuits on the card you are removing:
a.
Highlight the circuit(s). To select multiple circuits, press the Shift or Ctrl key.
b.
Click
Delete
.
c.
On the Delete Circuit dialog box, click
Yes
.
Step 6
Delete the SONET DCC termination on the card you are removing:
a.
Click the
Provisioning > Sonet DCC
tabs.
b.
From the SDCC Terminations list, click the SONET DCC you need to delete and click
Delete
.
Summary of Contents for ONS 15327
Page 22: ...Contents xxii Cisco ONS 15327 User Documentation June 2002 I N D E X ...
Page 30: ...Figures xxviii Cisco ONS 15327 User Documentation June 2002 ...
Page 44: ...Procedures xlii Cisco ONS 15454 Installation and Operations Guide R3 2 June 2002 ...
Page 540: ...Glossary GL 16 Cisco ONS 15327 User Documentation R3 3 June 2002 ...