Cisco Nexus 7000 Series Hardware Installation and Reference Guide
OL-23069-06
Appendix D Chassis and Module LEDs
describes the supervisor module LEDs.
Table D-2
Supervisor Module LEDs
LED
Status
Description
STATUS
Green
All diagnostics pass. The module is operational (normal initialization
sequence).
Red
The module has detected a slot ID parity error and will not power on or
boot up.
or
The module is not fully inserted and does not have a reliable connection
to the midplane.
or
The diagnostic test has failed.
Blinking
red
T
he inlet air temperature of the system has exceeded the safe operating
temperature limits of the module (a major environmental warning). The
module has been shut down to prevent permanent damage. The system
will be shut down after two minutes if this condition is not cleared.
or
The module is resetting, and both ejector levers are out.
Off
The module is not receiving power.
ID
Blinking
blue
The operator has activated this LED to identify this module in the chassis.
Off
This module is not being identified.
SYSTEM
Green
All chassis environmental monitors are reporting okay.
Amber
At least one power supply has failed or the power supply fan has failed.
Red
The temperature of the supervisor engine major threshold has been
exceeded.
Off
The slot has detected a slot ID parity error.
ACTIVE
Green
The supervisor module is operational and active.
Amber
The supervisor module is in standby mode.
PWR MGMT
Green
Sufficient power is available for all of the installed modules.
Amber
Insufficient power is available for all of the installed modules.
MGMT ETH
Green
The management port is operational.
Amber
The management port link has been disabled through the software.
Flashing
Amber
The management port link is bad and has been disabled due to a hardware
failure.
Off
The module has not detected a signal.
LINK
Green
The module has detected a link.
Off
The module does not detect a link.