![Cisco MXP Series The Physical Interface Manual Download Page 12](http://html.mh-extra.com/html/cisco/mxp-series/mxp-series_the-physical-interface-manual_64155012.webp)
Net Interface Socket
Net interface socket. 1 × X.21 / V.35 / RS449
with 1 × RS366 Call Control up to 2 Mbps
HD D-SUB 26 pin-out
External view of socket
9
1
10
19
18
26
V.35 DTE - DCE
Pin
Signal
Name
Description
1
FGND
Frame GND on
equipment
11
SD(A)
Send Data / Transmit
12
SD(B)
Send Data / Transmit
13
RD(A)
Receive Data
14
RD(B)
Receive Data
15
SCR(A)
Signal Clock Receive
16
SCR(B)
Signal Clock Receive
17
SCT(A)
Signal Clock Transmit
18
SCT(B)
Signal Clock Transmit
19
GND
1
Signal GND
22
RLSD(CD)
Received Line Signal
Detector / Carrier
Detect
23
RLSD(GND)
1
Signal GND
24
RI
Ring Indicator
25
LOS
Loss of Signal (KG194)
26
DTR
Data Terminal Ready
1) This pin is connected to ground for correct
operations
RS449 DTE - DCE
Pin
Signal
Name
Description
1
FGND
Frame GND
11
SD(A)
Send Data
12
SD(B)
Send Data
13
RD(A)
Receive Data
14
RD(B)
Receive Data
15
RT(A)
Receive Timing
16
RT(B)
Send Timing
17
ST(A)
Send Timing
18
ST(B)
Send Timing
19
GND
1
GND
20
TR(A)
Terminal Ready
21
TR(B)
Terminal Ready
22
RR(A)
Carrier Detect / Receiver
Ready
23
RR(B)
Carrier Detect / Receiver
Ready
24
IC
Incoming Call
25
LOS
Loss of Signal (KG194)
Frame GND is connected to pin 1 on DTE
1) This pin is connected to ground for correct operations
Note the following:
V.10 (RS423). For balanced signals
a “0” = low voltage, is defined as
terminal A positive with respect to
terminal B. For unbalanced signals
a “0” = low voltage, is defined as
terminal positive with respect to
GND. Cable length for Leased Line
Control should not exceed 20 m.
RS 366. All balanced inputs and
outputs (A and B) use balanced line
signals according to V.11 (RS 422),
while single ended signals are in
accordance with V.10 (RS423). The
“0” = low voltage definitions are the
same as for V.10 above. Max cable
length, as for V.10 above.
RS366 DTE - DCE
Pin
Signal
Name
Description
1
FGND
Frame GND
2
DPR
Digit Present
3
ACR
Abandon Call & Retry
4
CRQ
Call Request
5
PND
Present Next Digit
6
DLO
Data Line Occupied
7
NB1
Digit Bit 1
8
NB2
Digit Bit 2
9
NB4
Digit Bit 4
10
NB8
Digit Bit 8
X.21 DTE - DCE
Pin
Signal
Name
Description
1
FGND
Frame GND
11
T(A)
Send Data / Transmit
12
T(B)
Send Data / Transmit
13
R(A)
Received Data /
Receive
14
R(B)
Received Data /
Receive
15
S(A)
Signal Element Timing
16
S(B)
Signal Element Timing
20
C(A)
Terminal Ready /
Control
21
C(B)
Terminal Ready /
Control
22
I(A)
Carrier Detect
23
I(B)
Carrier Detect
12
MXP Series Codecs
Physical interface guide
D14790.01 MXP Series Codec Physical Interface Guide, May 2011.
© 2011 Cisco Systems, Inc. All rights reserved.
www.cisco.com