Terminal lug
2
Ground lug mounting points
1
M4 screws (2)
3
Step 5
Use a ratcheting torque screwdriver to tighten the ground screws to 11 to 14 in-lbs.
Step 6
Attach the other end of the ground wire to an appropriate ground.
Installing the Power Supply Module in the Router
Step 1
Ensure that the power is off at the AC or DC circuits.
Locate the circuit breakers, turn them OFF, and lock out the circuit.
If the power is not off at the AC or DC circuit breaker, do not touch the power-input terminal.
Warning
Step 2
Use a Phillips screwdriver to loosen the two captive screws of the blank power-supply module and gently pull it out.
Step 3
Insert the power supply module into the slot, and gently push it in. Make sure that the alignment tabs of the module fit
into the chassis, as shown in the following figure.
Cisco Catalyst IR8340 Rugged Series Router Hardware Installation Guide
38
Power Supply Installation
Installing the Power Supply Module in the Router