Installation Safety and Site Preparation
This document provides information you should be aware of before installing the Cisco 1120 Connected Grid Router,
such as safety information, installation recommendations, and site requirements.
These topics are discussed:
Safety Recommendations, page 8
General Site Requirements, page 9
Router Environmental Requirements, page 10
Power Guidelines and Requirements, page 10
Network Cabling Specifications, page 10
Required Tools and Equipment for Installation and Maintenance, page 11
Note:
To see translated warnings that appear in this publication, see the Regulatory Compliance and Safety Information
document that came with the router.
Warning:
Only trained and qualified personnel should be allowed to install, replace, or service this equipment.
Statement 1030
Warning:
Ultimate disposal of this product should be handled according to all national laws and regulations.
Statement 1040
Warning:
This unit might have more than one power supply connection. All connections must be removed to
de-energize the unit. Statement 1028
Warning:
This product relies on the building’s installation for short-circuit (overcurrent) protection. Ensure that the
protective device is rated not greater than: Maximum 15 A, 120 Vac or Maximum 10 A, 230 Vac Statement 1005
Warning:
Take care when connecting units to the supply circuit so that wiring is not overloaded. Statement 1018
Warning:
Installation of the equipment must comply with local and national electrical codes. Statement 1074
Warning:
This unit is intended for installation in restricted access areas. A restricted access area can be accessed
only through the use of a special tool, lock and key, or other means of security. Statement 1017
Warning:
Blank faceplates and cover panels serve three important functions: they prevent exposure to hazardous
voltages and currents inside the chassis; they contain electromagnetic interference (EMI) that might disrupt other
equipment; and they direct the flow of cooling air through the chassis. Do not operate the system unless all cards,
faceplates, front covers, and rear covers are in place.
Statement 1029
Warning:
Read the installation instructions before connecting the system to the power source. Statement 1004