60

Pin

1

25

Pin

J1−49

J1−48

MODE_1

GND

Shorting
group

J1−51

J1−52

GND

MODE_DCE

Shorting
group

J1−46

Shield_GND Single

J2−1

Shield
GND

J1−11

J1−12

TxD/RxD+

TxD/RxD−

Twisted pair
no. 6

−−−>

−−−>

J2−4

J2−22

SD+

SD−

J1−24

J1−23

TxC/RxC+

TxC/RxC−

Twisted pair
no. 9

<−−−

<−−−

J2−5

J2−23

ST+

ST−

J1−28

J1−27

RxD/TxD+

RxD/TxD−

Twisted pair
no. 11

<−−−

<−−−

J2−6

J2−24

RD+

RD−

J1−9

J1−10

RTS/CTS+

RTS/CTS−

Twisted pair
no. 5

−−−>

−−−>

J2−7

J2−25

RS+

RS−

J1−26

J1−25

RxC/TxCE+

RxC/TxCE−

Twisted pair
no. 10

<−−−

<−−−

J2−8

J2−26

RT+

RT−

J1−1

J1−2

CTS/RTS+

CTS/RTS−

Twisted pair
no. 1

<−−−

<−−−

J2−9

J2−27

CS+

CS−

J1−44

J1−45

LL/DCD

Circuit_GND

Twisted pair
no. 12

−−−>

J2−10

J2−37

LL

SC

J1−3

J1−4

DSR/DTR+

DSR/DTR−

Twisted pair
no. 2

<−−−

<−−−

J2−11

J2−29

DM+

DM−

J1−7

J1−8

DTR/DSR+

DTR/DSR−

Twisted pair
no. 4

−−−>

−−−>

J2−12

J2−30

TR+

TR−

J1−5

J1−6

DCD/DCD+

DCD/DCD−

Twisted pair
no. 3

<−−−

<−−−

J2−13

J2−31

RR+

RR−

J1−13

J1−14

TxCE/TxC+

TxCE/TxC−

Twisted pair
no. 7

−−−>

−−−>

J2−17

J2−35

TT+

TT−

J1−15

J1−16

Circuit_GND

Circuit_GND

Twisted pair
no. 9

J2−19

J2−20

SG

RC

Summary of Contents for EIA/TIA-449 Serial Cable CAB-449FC

Page 1: ... restricted to specific software and hardware versions The information in this document was created from the devices in a specific lab environment All of the devices used in this document started with a cleared default configuration If your network is live make sure that you understand the potential impact of any command Conventions For more information on document conventions see the Cisco Techni...

Page 2: ... this reason it is important to select the correct product number from the table below The cable gender for this product part number 72 0795 01 is Male DB 60 to Male DB 37 mode DTE The CAB 449MT cable is used in the Cisco 7000 family Cisco 4000 series Cisco 3600 series Cisco 2500 series Cisco 1600 series Cisco access servers and AccessPro PC cards This cable has a male DB 60 connector on the Cisco...

Page 3: ...wisted pair no 5 J2 7 J2 25 RS RS J1 26 J1 25 RxC TxCE RxC TxCE Twisted pair no 10 J2 8 J2 26 RT RT J1 1 J1 2 CTS RTS CTS RTS Twisted pair no 1 J2 9 J2 27 CS CS J1 44 J1 45 LL DCD Circuit_GND Twisted pair no 12 J2 10 J2 37 LL SC J1 3 J1 4 DSR DTR DSR DTR Twisted pair no 2 J2 11 J2 29 DM DM J1 7 J1 8 DTR DSR DTR DSR Twisted pair no 4 J2 12 J2 30 TR TR J1 5 J1 6 DCD DCD DCD DCD Twisted pair no 3 J2 ...

Page 4: ...a female DB 37 connector on the network end EIA TIA 449 DCE Cable Pinouts DB 60 to DB 37 The table below shows the EIA TIA 449 DCE cable pinouts DB 60 to DB 37 Note The arrows indicate signal direction indicates DTE to DCE indicates DCE to DTE 60 Pin1 Signal Description Direction 25 Pin Signal J1 49 J1 48 MODE_1 GND Shorting group J1 46 Shield_GND Single J2 1 Shield GND J1 28 J1 27 RxD TxD RxD TxD...

Page 5: ...r no 2 J2 12 J2 30 TR TR J1 5 J1 6 DCD DCD DCD DCD Twisted pair no 3 J2 13 J2 31 RR RR J1 26 J1 25 RxC TxCE RxC TxCE Twisted pair no 10 J2 17 J2 35 TT TT J1 15 J1 16 Circuit_GND Circuit_GND Twisted pair no 8 J2 19 J2 20 SG RC Related Information Technical Support Cisco Systems All contents are Copyright 2006 2007 Cisco Systems Inc All rights reserved Important Notices and Privacy Statement Updated...

Reviews: