Step 1
Place the mounting plate on the selected mounting location on the pole.
Step 2
Mark the drilling locations on the pole through the clearance holes and remove the mounting plate.
Step 3
Drill holes completely through the pole at the points you marked in Step 2.
Step 4
Position the mounting plate over the drilled holes. Align the clearance holes on the mounting plate with the drilled holes.
Step 5
Place a standard washer against one of the clearance holes on the mounting plate, then feed the bolt through the washer,
clearance hole, and drilled hole. Push the bolt all the way through the pole. See
Figure 20: Mounting Plate Details, on
Step 6
Follow these steps on the opposite side of the pole:
a) Place a fender washer on the end of the bolt, and then a nut.
b) Hand tighten the nut.
Step 7
Repeat Step 5 and Step 6 for the second bolt.
Step 8
Use a socket wrench to evenly tighten both bolts to finish installing the mounting plate on the wooden pole (see the
following figure).
Figure 24: Mounting Plate Installed on Wooden Pole with Through Bolts
Description
Item
5/8-in. through bolts (2)
1
Wood pole
2
Attach the Mounting Bracket to the Mounting Plate
This section describes how to attach the mounting bracket to the mounting plate.
Cisco Catalyst IR8140 Heavy Duty Series Router Hardware Installation Guide
35
Mounting the Router
Attach the Mounting Bracket to the Mounting Plate