Page 1: ...es in this order Preparing for Installation This section provides information about these topics Warnings These warnings are translated into several languages in the Regulatory Compliance and Safety Information for this switch Before working on equipment that is connected to power lines remove jewelry including rings necklaces and watches Metal objects will heat up when connected to power and grou...

Page 2: ...type 4 minimum enclosure rating standards Statement 1063 Warning This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available Statement 1024 Warning This unit might have more than on...

Page 3: ...without derating This equipment is considered Group 1 Class A industrial equipment according to IEC CISPR Publication 11 Without appropriate precautions there may be potential difficulties ensuring electromagnetic compatibility in other environments due to conducted as well as radiated disturbance This equipment is supplied as open type equipment It must be mounted within an enclosure that is suit...

Page 4: ...essive side to side movement of the unit it is advised to install DIN rail stop plates such as mouser part numbers 653 PFP M 651 1201662 or 845 CA402 These end stops can be installed on one or both sides or the unit to limit excessive side to side movement that typically occurs in high vibration environments Note When determining where to place the switch observe these guidelines Before installing...

Page 5: ...an execute the sync command to copy Flash to SDFlash and make SDFlash the primary storage then remove the SD card It is strongly recommended that you use the SD card to boot or store the config for future easy replacement in case of a hardware failure To install or replace the flash memory card follow these steps 1 On the front of the switch locate the door that protects the flash memory card slot...

Page 6: ...al You can also enter CLI commands through the console port For more information about this process see Accessing the CLI Through the Console Port Attaching an Expansion Module Optional If you re installation calls for use of one of the expansion modules listed in Switch Models use the following procedure to attach the module to the switch Do not attach any expansion module to a switch while the s...

Page 7: ...Switch Installation 7 Switch Installation Attaching an Expansion Module Optional ...

Page 8: ... side of switch along with tabs on top and bottom left rear of module and holes at top and bottom right rear of switch and press module and switch together so that theelectrical connections engage and the screw holes Switch Installation 8 Switch Installation Attaching an Expansion Module Optional ...

Page 9: ... pair of stu size 6 ring terminals such as Hollingsworth part number R3456B or equivalent Crimping tool such as Thomas Bett part number WT4000 ERG 2001 or equivalent 10 gauge copper ground wire For DC power connections use UL and CSA rated style 1007 or 1569 twisted pair copper appliance wiring material AWM wire Wire stripping tools for stripping 10 and 14 gauge wires A number 2 Phillips screwdriv...

Page 10: ...tween any other switch assembly Caution Grounding the Switch Make sure to follow any grounding requirements at your site This equipment must be grounded Never defeat the ground conductor or operate the equipment in the absence of a suitably installed ground conductor Contact the appropriate electrical inspection authority or an electrician if you are uncertain that suitable grounding is available ...

Page 11: ...idelines to determine the wire length to be stripped 3 Insert the ground wire into the ring terminal lug and using a crimping tool crimp the terminal to the wire If two ring terminals are being used repeat this action for a second ring terminal Figure 2 Crimping the Ring Terminal 4 Slide the ground screw through the terminal 5 Insert the ground screw into the functional ground screw opening on the...

Page 12: ...ibe the steps required to connect the power converter to an AC power source Preparing the AC Power Connection To connect the power converter to an AC power source you need an AC power cord Power cord connector types and standards vary by country Power cord wiring color codes also vary by country You must to have a qualified electrician select prepare and install the appropriate power cord to the p...

Page 13: ...e and neutral wire leads into the terminal block line and neutral connections Make sure that you cannot see any wire lead Ensure that only wire with insulation extends from the connectors 5 Tighten the line and neutral terminal block screws Torque to 10 in lb 1 13Nm Note 6 Replace the plastic cover over the terminal block 7 Connect the other end of the wiring to your AC power source Connecting the...

Page 14: ...th ground wire connection terminal block screw Torque to 8 in lb not to exceed 10 in lb Note An exposed wire lead from a DC input power source can conduct harmful levels of electricity Be sure that no exposed portion of the DC input power source wire extends from the power and relay connector Statement 122 Warning 7 Insert the twisted pair wire leads into the terminal block line and neutral connec...

Page 15: ... 1569 twisted pair copper appliance wiring material AWM wire Caution To wire the switch to a DC power source follow these steps 1 Locate the two power connectors on the switch front panel labeled DC A and DC B 2 Identify the connector positive and return DC power connections The labels for power connectors DC A and DC B are on the switch panel as displayed below Connection Label Positive DC power ...

Page 16: ...to two power sources Figure 5 Removing the Power Connectors from the Switch Power Connectors 1 6 On the power connector insert the exposed part of the positive wire into the connection labeled and the exposed part of the return wire into the connection labeled Make sure that you cannot see any wire lead Only wire with insulation should extend from the connector Switch Installation 16 Switch Instal...

Page 17: ... A receptacle on the switch front panel and the other into the DC B receptacle Failure to securely tighten the captive screws can result in an electrical arc if the connector is accidentally removed Statement 397 Warning Use twisted pair supply wires suitable for 86 F 30 C above surrounding ambient temperature outside the enclosure Statement 1067 Warning Installation of the equipment must comply w...

Page 18: ...ing To prevent the switch from overheating ensure these minimum clearances Top and bottom 2 0 in 50 8 mm Exposed side not connected to the module 2 0 in 50 8 mm Front 2 0 in 50 8 mm Caution Installing the Switch on a DIN Rail The switch ships with a spring loaded latch on the rear panel for a mounting on a DIN rail You can install the switch as a standalone device on the DIN rail or with the expan...

Page 19: ...arm wires as described in Connecting Alarm Circuits on page 20 For instructions on how to remove the switch from a DIN rail see Removing the Switch from a DIN Rail on page 19 Note Removing the Switch from a DIN Rail To remove the switch from a DIN rail follow these steps 1 Ensure that power is removed from the switch and disconnect all cables and connectors from the front panel of the switch Switc...

Page 20: ...larms The alarm input circuits are designed to sense if the alarm input is open or closed relative to the alarm input reference pin Each alarm input can be configured as an open or closed contact The alarm output relay circuit has a normally open and a normally closed contact Alarm signals are connected to the switch through the six pin alarm connector Three connections are dedicated to the two al...

Page 21: ...relay circuit must be an isolated source and limited to less than or equal to 24 VDC 1 0A or 48VDC 0 5A Caution To reduce risk of electric shock and fire the alarm ports must be connected to an IEC60950 IEC 62368 compliant limited power source Caution Wire connections to the power and alarm connectors must be UL and CSA rated style 1007 or 1569 twisted pair copper appliance wiring material AWM wir...

Page 22: ...lation from the wires Stripping more than the recommended amount of wire can leave exposed wire from the alarm connector after installation 4 Insert the exposed wires for the external alarm device into the connections based on an alarm input or output circuit setup For example to wire an alarm input circuit complete the IN1 and REF connections 5 Use a ratcheting torque flathead screwdriver to tigh...

Page 23: ...rm device circuit is wired as an alarm output circuit that works on a normally open contact basis the NO and COM connections complete the circuit Attaching the Alarm Connector to the Switch Failure to securely tighten the captive screws can result in an electrical arc if the connector is accidentally removed Statement 397 Warning To attach the alarm connector to the front panel of the switch follo...

Page 24: ... ports To prevent electrostatic discharge ESD damage follow your normal board and component handling procedures Caution To connect to 10BASE T 100BASE TX or 1000BASE T devices follow these steps 1 When connecting to workstations servers routers and Cisco IP phones connect a straight through cable to an RJ 45 connector on the front panel When connecting to 1000BASE T compatible devices use a twiste...

Page 25: ...ng SFP Modules into SFP Module Ports Do not install or remove the SFP module with fiber optic cables attached to it because of the potential damage to the cables the cable connector or the optical interfaces in the SFP module Disconnect all cables before removing or installing an SFP module Removing and installing an SFP module can shorten its useful life Do not remove and insert SFP modules more ...

Page 26: ... to open it use a small flat blade screwdriver or other long narrow instrument to open the bale clasp latch 5 Grasp the SFP module between your thumb and index finger and carefully remove it from the module slot 6 Place the removed SFP module in an antistatic bag or other protective environment Connecting to SFP Modules This section describes how to connect to a fiber optic SFP port For instructio...

Page 27: ...sequence allows the switch to boot up in less than 90 seconds Where to Go Next If the default configuration is satisfactory the switch does not need further configuration You can use any of these management options to change the default configuration Start the Web UI which is in the switch memory to manage individual and standalone switches This is an easy to use web interface that offers quick co...