• PoE with a supporting switch
• The Underwriter Laboratories (UL)-approved Listed Power Adapter must
meet the following minimum specifications—rated output of 42.5 to 57 Vdc,
min. 1.11A, Tma is 50°C minimum, altitude is 3048m minimum.
• If 802.3af is used, all the radios get switched off. Ethernet gets downgraded
to 1 GbE. The USB port is also off.
Note
• Operating temperature:
• C9136I: 32°F to 122°F (0°C to 50°C)
When installing the C9136I AP in an environment where the ambient temperature is in the range of 104°F
and 122°F (>40°C and 50°C), the access point configuration will change from 8x8 to 4x4 on the 5-GHz radios,
and the uplink Ethernet will downgrade to 1 GbE. However, the USB port will remain enabled.
Note
We recommend that you make a site map showing access point locations so that you can record the device
MAC addresses from each location and return them to the person who is planning or managing your wireless
network.
Mounting the Access Point
Cisco Catalyst 9136I Series access points can be mounted in several configurations:
• Suspended ceiling
• Hard ceiling
• Wall
• Electrical or network box
• Above a suspended ceiling
For access point-mounting instructions, go to the following URL:
http://www.cisco.com/c/en/us/td/docs/wireless/access_point/mounting/guide/apmount.html
The standard mounting hardware supported by the AP is listed in .
Cisco Catalyst 9136I Series Access Point Hardware Installation Guide
18
Installation Overview
Mounting the Access Point