Chapter 15 Configuring Power over Ethernet
PoE Policing and Monitoring
Interface Admin Oper Admin Oper Cutoff Oper
State State Police Police Power Power
--------- ------ ---------- ---------- ---------- ------ -----
Gi2/1 auto errdisable errdisable overdrawn 0.0 0.0
Displaying Power Policing on an Interface
You can display power policing on an interface, on a module, or for all the PoE-capable line cards in a
chassis.
The following example shows output for the
show power inline police
command:
Switch#
show power inline police
Available:623(w) Used:6(w) Remaining:617(w)
Interface Admin Oper Admin Oper Cutoff Oper
State State Police Police Power Power
--------- ------ ---------- ---------- ---------- ------ -----
Gi2/1 auto off none n/a n/a 0.0
Gi2/2 auto on none n/a n/a 16.7
Gi2/3 auto off errdisable n/a 0.0 0.0
Gi2/4 auto on errdisable ok 16.6 11.4
Gi2/5 auto on log ok 16.6 11.2
Gi2/6 auto on errdisable overdrawn 0.0 0.0
The following table lists the interface and the status.
If you enter the
show power inline
command at the global level
(show power inline police
), the last
line of the output under the Oper Power field displays the total of true inline power consumption of all
devices connected to the switch.
Configuring Errdisable Recovery
By default, errdisable auto recovery for inline-power is disabled; when an interface is placed in an
errdisable state because of an inline-power policing violation, it remains in that state. You must enter
shut
and then
no shut
on the affected interface to revive it.
Interface Configuration
State
Gi2/1
No PD connected, no policing configured.
Gi2/2
PD connected, no policing configured.
Gi2/3
No PD connected, policing configured (is enabled when PD is
connected). Policing action is errdisable.
Gi2/4
PD connected, policing configured. Configured policing action is
errdisable. Port is currently operating within policing limits.
Gi2/5
PD connected, policing configured. Configured policing action is log.
Port is currently operating within policing limits.
Gi2/6
PD connected, policing configured. Configured policing action is
errdisable. Port is currently in errdisable state as it has overdrawn its
policed power level.