23
Installation and Configuration Note for the Catalyst 4000 Layer 3 Services Module
78-10164-03
Removing and Installing a Layer 3 Services Module
Step 1
Take the necessary precautions to prevent ESD damage.
Step 2
Choose a slot for the new module. Ensure that you have enough clearance to accommodate any
interface equipment that you will connect directly to the module ports. If possible, place modules
between empty slots.
Step 3
Holding the module front panel with one hand, and placing your other hand under the carrier to
support the module, as shown in Figure 5, align the edges of the module carrier with the slot guides on
the sides of the switch chassis and slide the module halfway into the chassis.
Figure 5
Catalyst 4003: Installing the Module in the Chassis
Step 4
Pivot the two module ejector levers out and away from the faceplate. The ejector levers are shown
pivoted out in Figure 5.
Step 5
Carefully slide the module the rest of the way into the slot until the notches on both ejector levers
engage the chassis sides.
Step 6
Using the thumb and forefinger of each hand, simultaneously pivot in both ejector levers, as shown in
Figure 6, to fully seat the module in the backplane connector.
Caution
Always use the ejector levers when installing or removing modules. A module that is only
partially seated in the backplane will cause the system to halt and reset.
26566
THIS ASSEMBLY
CONTAINS
ELECTROSTATIC-
SENSITIVE DEVICES
CAUTION
0%
100%
Power Supply 1
Power Supply 2
1
13
1
13