background image

a) Locate the PFU bay labeled Power Filter Unit 1 on the lower-left rear of the chassis.
b) Use a Phillips #2 screwdriver to loosen the four screws that secure the PFU in to the chassis.
c) Grasp the handle on the PFU and gently pull the PFU toward you. The PFU should slide easily out of the chassis.

Place it to the side for re-installation later.

d) Repeat step b and step c for the PFU located in the bay labeled Power Filter Unit 2 located on the lower-right side

of the chassis.

Step 4

Proceed to either the

Flush Mount Installation of the Chassis, on page 57

or

Mid-Mount Installation of the Chassis, on

page 58

, based on the mounting option you are using.

Flush Mount Installation of the Chassis

Follow the instructions below to perform the flush mount installation of the chassis.

Step 1

Position the chassis in the equipment rack so that the flanges of the mounting brackets at the front of the chassis are flush
with the mounting rails of the equipment rack.

Step 2

Mount the chassis to the rails of the equipment rack. Use the hardware that was supplied with the equipment rack. Begin
with the two bottom holes and work your way up until all four holes on each flange are secured.

ASR 5000 Installation Guide    

57

Chassis Installation

Flush Mount Installation of the Chassis

Summary of Contents for ASR 5000

Page 1: ...ide First Published September 30 2015 Last Modified March 31 2016 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Page 2: ...e encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product no...

Page 3: ...ription 6 Slot Numbering 6 Rear Slot Numbering for Half Height Line Cards 7 Rear Slot Numbering with Full height Line Cards 7 Mounting Options 7 Midplane Architecture 8 320 Gbps Switch Fabric 9 32 Gbps Control Bus 9 System Management Bus 9 280 Gbps Redundancy Bus 10 OC 48 TDM Bus 10 SPIO Cross Connect Bus 11 Power Filter Units 11 Fan Tray Assemblies 12 Lower Fan Tray 12 Air Filter Assembly 12 Uppe...

Page 4: ...2 Central Office Alarm Interface 23 Redundancy Crossbar Card RCC 23 Fast Ethernet Line Card FLC2 24 Gigabit Ethernet Line Card GLC2 25 Quad Gigabit Ethernet Line Card QGLC 27 10 Gigabit Ethernet Line Card XGLC 29 Optical Line Card OLC2 32 Channelized Line Card CLC2 34 Card Interlock Switch 38 Card Identifiers 38 C H A P T E R 2 Installation Procedure Overview 41 Chassis Components 42 Installation ...

Page 5: ...is 60 Re Installing Chassis Sub components 62 C H A P T E R 4 Application Card Installation 67 Chassis Slot Numbering and Assignments 67 ASR 5000 Platform 68 Packet Processing Card Redundancy 68 Recommended Minimum Chassis Configuration 69 Installing Application Cards 69 C H A P T E R 5 Line Card Installation 73 Chassis Slot Numbering and Assignments 73 Line Card Redundancy 76 Side by side Redunda...

Page 6: ...Interface 96 BITS Timing Configuration 97 Connecting to the CO Alarm Interface 97 Electrical Characteristics 100 Central Office Alarm Wiring Example 100 C H A P T E R 7 Cabling the Fast Ethernet 10 100 Line Card 103 FLC2 Interfaces 103 C H A P T E R 8 Cabling the Gigabit Ethernet Line Cards 107 Gigabit Ethernet Line Card GLC2 108 Quad Gigabit Ethernet Line Card QGLC 109 RJ 45 SFP Module Detail 111...

Page 7: ...FU 137 Checking the LEDs on the SMC s 139 SMC Run Fail LED States 140 SMC Active LED States 141 SMC Standby LED States 142 SMC Status LED States 143 SMC Service LED States 143 SMC Busy LED States 143 Checking the LEDs on Packet Processing Cards 144 PSCA PSC2 PSC3 and PPC Run Fail LED States 145 PSCA PSC2 PSC3 and PPC Active LED States 146 PSCA PSC2 PSC3 and PPC Card Standby LED States 147 Checking...

Page 8: ... Line Card Active LED States 161 Channelized Line Card Standby LED States 162 Checking the Alarm and Link LEDs on the Channelized Line Card 2 163 Checking the LEDs on the RCC s 164 RCC Run Fail LED States 165 RCC Active LED States 166 RCC Standby LED States 167 Completing Initial System Configuration 167 C H A P T E R 1 3 System Monitoring 169 Monitoring 169 Daily Standard Health Check 169 Periodi...

Page 9: ...ilter Unit 197 Determining that a PFU has Failed 197 Removing the Failed PFU 198 Installing the Replacement PFU 200 What to do with the Failed PFU 203 C H A P T E R 1 8 Replacing Upper or Lower Fan Tray 205 Determining Whether a Fan Tray Needs Replacing 205 Using the CLI 206 Using SNMP Traps and MIB Objects 206 Removing an Upper Fan Tray 207 Installing an Upper Fan Tray 208 Removing a Lower Fan Tr...

Page 10: ...Specifications 229 Physical Dimensions 229 Weights 230 Power Specifications 231 Estimating Power Requirements 232 Mounting Requirements 232 Interface Specifications 234 SPIO Card Interfaces 235 Console Port 235 Console Cable Specifications 235 Fiber SFP Interface 237 10 100 1000 Mbps RJ 45 Interface 237 Central Office Alarm Interface 238 Electrical Characteristics 240 Central Office Alarm Wiring E...

Page 11: ... 247 Federal Communications Commission Warning 247 ICS Notice 248 Laser Notice 248 Safety Certifications 248 Electrical Certifications 248 Environmental Certifications 248 Acoustic Noise 249 Electromagnetic Compatibility EMC Compliance 249 Japan VCCI A 249 Korean EMC 249 C H A P T E R 2 3 Environmental Specifications 251 Operating and Storage Parameters 251 Supported Environmental Standards 252 Ch...

Page 12: ...Return Locations 267 Packaging ASR 5000 Cards 267 Application Cards 267 Application Card Types 267 Packaging an Application Card 267 Line Cards except XGLC 269 Half Height Line Card Types 269 Packaging a Half height Line Card 270 10 Gigabit Ethernet Card XGL 273 XGLC Card Types 273 Packaging a Full Height XGLC 273 A P P E N D I X D Spare Component Recommendations 275 Spare Component Recommendation...

Page 13: ...er Support page xiv Conventions Used The following tables describe the conventions used throughout this documentation Description Notice Type Provides information about important features or instructions Information Note Alerts you of potential damage to a program device or system Caution Alerts you of potential personal injury or fatality May also alert you of potential electrical hazards Warning...

Page 14: ...ed as menu or sub menu names Dimensions Dimensions such as size weight and temperature are first presented in their primary measurements imperial or metric followed by the converted measurement metric or imperial in parentheses Related Documentation The most up to date information for this product is available in the product Release Notes provided with each product release The following documents ...

Page 15: ...t documentation or to submit a service request A valid username and password are required to access this site Please contact your Cisco sales or service representative for additional information ASR 5000 Installation Guide xv About this Guide Contacting Customer Support ...

Page 16: ...ASR 5000 Installation Guide xvi About this Guide Contacting Customer Support ...

Page 17: ...platform is designed for deployment in multimedia enabled core networks It features a distributed architecture that allows all tasks and services to be allocated across the entire platform This platform allows operators to deploy more efficient mobile networks that support a greater number of concurrent calls optimize resource usage and deliver enhanced services while providing scalability ASR 500...

Page 18: ...cards are active and one packet processing card is standby redundant This minimal configuration is designed to protect against software failures only Table 1 Minimum Card Configurations Maximum per Chassis Redundant HW SWConfiguration Note 2 Redundant HW Configuration Note 1 Supported ASR 5000 Product Component Application Cards 2 2 2 All System Management Card SMC End of Life not supported in Rel...

Page 19: ... 2 All Redundancy Crossbar Card RCC End of Life replaced by FLC2 Fast Ethernet Line Card FELC 28 See Note 4 below 2 All Fast Ethernet Line Card 2 FLC2 End of Life replaced by GLC2 Gigabit Ethernet Line Card GELC 28 See Note 4 below 2 All Gigabit Ethernet Line Card 2 GLC2 28 2 All Quad Gigabit Ethernet Line Card QGLC 14 2 All 10 Gigabit Ethernet Line Card XGLC 28 2 SGSN only Optical Line Card 2 OLC...

Page 20: ...e physical maximum number of line cards since they are inactive behind standby packet service cards The 10 Gigabit Ethernet Line Card XGLX is a full height line card that takes up the upper and lower slots in the back of the chassis When referring to an installed XGLC use the upper slot number only Slot numbering for other installed half height cards is maintained 17 to 32 and 33 to 48 regardless ...

Page 21: ...ir through the chassis for cooling and ventilation It then exhausts warmed air through the vents at the upper rear of the chassis 3 Upper bezel Covers the upper fan tray bay 4 Lower fan tray cover EMI shield Secures the lower fan tray assembly in place and serves as an EMI shield The cover also provides an air baffle allowing air to enter into the chassis 5 Lower bezel Covers the lower fan tray ba...

Page 22: ... ASR 5000 Figure 3 Chassis Slot Numbers The following table shows the front slot numbers and their corresponding rear slot numbers Table 3 Front and Rear Slot Numbering Relationship Slot Number Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Front 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Rear Top Slots ASR 5000 Installation Guide 6 ASR 5000 Hardware Platform Overview Chassis Description ...

Page 23: ...full height line cards that require the removal of the half height card guides to accommodate the cards In this case only the upper slot number is used to refer to the XGLC For half height cards installed with the XGLCs the half height slot numbering scheme is maintained For example XGLCs installed in slots 17 and 32 also take up slots 33 and 48 but are referred to as cards in slots 17 and 32 only...

Page 24: ...and rear chassis slots The connectors on the midplane provide intra chassis communications power connections and data transport paths between the various installed cards The midplane also contains two independent 48 VDC busses not shown that distribute redundant power to each card within the chassis Figure 4 Midplane Switch Fabric Architecture Table 4 Midplane and Bus Descriptions Description Item...

Page 25: ... The Control Bus features redundant 32 Gbps Ethernet paths that interconnect all control and management processors within the system The bus uses a full duplex Gigabit Ethernet GigE switching hierarchy from both SMCs to each of the 14 application card slots in the chassis Each application card is provisioned with a GigE switch to meet its specific needs This bus also interconnects the two SMC modu...

Page 26: ...ts line card slots 33 39 and 42 48 lower rear slots Each serial link facilitates up to 5 Gbps symbol rate equivalent to 4 Gbps of user data traffic in each direction Therefore the Redundancy Bus provides 140 Gbps symbol rate 112 Gbps user data of throughput per RCC 280 Gbps symbol rate 224 Gbps user data total for both OC 48 TDM Bus The system also hosts a dual OC 48 TDM bus consisting of 128 inde...

Page 27: ...power from the site s power distribution frame PDF to the chassis and its associated cards Each load sharing PFU operates independently of the other to ensure maximum power feed redundancy The maximum input operating voltage range of the PFU is 40 VDC to 60 VDC the nominal range is 48 VDC to 60 VDC The ASR 5000 does not offer an AC power supply option If only AC power is available at the installat...

Page 28: ... In the event of a fan failure or other temperature related condition the SMC notifies all operable fans in the system to switch to high speed and generates an alarm Lower Fan Tray The lower fan tray assembly contains multiple fans and pulls ambient air into the chassis from the lower front and sides of the chassis The air is then pushed upward across the cards and midplane to support vertical con...

Page 29: ...lter for each deployed chassis should be kept on site This allows qualified service personnel to quickly replace the filter when necessary Important Upper Fan Tray The upper fan tray unit contains multiple fans that exhaust air from the upper rear and sides of the chassis Figure 9 Upper Fan Tray Chassis Airflow Airflow within the chassis complies with Telcordia recommendations to ensure proper ver...

Page 30: ...or Type II PCMCIA cards Use these cards to load and store configuration data software updates buffer accounting information and store diagnostic or troubleshooting information There is also a Type II CompactFlash slot on the SMC that hosts configuration files software images and the session limiting feature use license keys for the system The SMC provides the following major functions Non blocking...

Page 31: ...le 6 SMC Callouts Description Item Card Ejector Levers Use to insert remove card to from chassis 1 Interlock Switch Sliding this switch downward on an active SMC initiates an immediate switchover to the standby SMC 2 ASR 5000 Installation Guide 15 ASR 5000 Hardware Platform Overview System Management Card SMC ...

Page 32: ...ve Disks RAID HD RAID ids configurable via CLI commands RAID control mechanisms allow xDR charging data to be written to the hard disks on both the active and standby SMCs for later upload to a suitable local or remote storage server Event logs related to disk and RAID include disk name serial number and RAID UUID for reference They are generated at the Critical Error Warning and Informational lev...

Page 33: ...xts You cannot mix packet processing card types in the same chassis Caution Specialized hardware engines support parallel distributed processing for compression classification traffic scheduling forwarding packet filtering and statistics The packet processing cards use control processors to perform packet processing operations and a dedicated high speed network processing unit NPU The NPU does the...

Page 34: ...ms processor intensive tasks such as encryption or data compression Packet processing cards can be installed in chassis slots 1 through 7 and 10 through 16 Each card can either Active available to the system for session processing or redundant a standby component available in the event of a failure The front panel of a packet processing card with its major components is shown below Figure 11 Packe...

Page 35: ... as a 4 way multi processor The PSC2 has a dedicated security processor that provides the highest performance for cryptographic acceleration of next generation IP Security IPSec Secure Sockets Layer SSL and wireless LAN WAN security applications with the latest security algorithms PSC2s should not be mixed with PSC3s Due to the different processor speeds and memory configurations the PSC2 cannot b...

Page 36: ...tive packet processing card PSC3s must not be mixed with PSC2s The PSC3 is fully redundant with a spare PSC3 Packet Processor Card PPC Description The PSCA has reached its end of life and is no longer available for purchase It is not supported in StarOS Release 16 0 and higher Line Cards The following rear loaded cards are currently supported by the system Switch Processor I O SPIO Card The SPIO c...

Page 37: ...hernet interfaces to connect optical transceivers 4 10 100 1000 Mbps Ethernet Management LAN Interfaces Two RJ 45 interfaces supporting 10 100 Mbps or 1 Gbps Ethernet 5 Console Port RJ 45 interface used for local connectivity to the command line interface CLI See Cabling the Switch Processor Input Output Line Card for more information 6 BITS Timing Interface Optional Either an analog E1 BNC coaxia...

Page 38: ...the command line interface CLI A 9 pin to RJ 45 console cable is supplied with each SPIO card The console cable must provide carrier detect when attached in a null modem configuration Should connection to a terminal server or other device requiring a 25 pin D subminiature connector be required a specialized cable can be constructed to support DB 25 to RJ 45 connectivity The baud rate for this inte...

Page 39: ... ensures session integrity If a packet processing card were to experience a failure IP traffic would be redirected to and from the LC to the redundant packet processing card in another slot Each RCC connects up to 14 line cards and 14 packet processing cards for a total of 28 bidirectional links or 56 serial 2 5 Gbps bidirectional serial paths The RCC provides each packet processing card with a fu...

Page 40: ...ble for purchase It has been replaced by the FLC2 Important 100Base Tx full or half duplex Ethernet on CAT 5 shielded twisted pair STP or unshielded twisted pair UTP cable 10Base T full or half duplex Ethernet on CAT 3 4 or 5 STP or UTP cable Use shielded cabling whenever possible to further protect the chassis and its installed components from ESD or other transient voltage damage Important The F...

Page 41: ...J 45 interfaces for R P interface connectivity carrying user data Ports are numbered 1 through 8 from top to bottom 4 Gigabit Ethernet Line Card GLC2 The GLC2 installs directly behind its respective packet processing card providing network connectivity to the packet data network The GLC2 Ethernet 1000 supports a variety of 1000 Mbps optical and copper interfaces based on the type of Small Form fac...

Page 42: ... to 100 meters of CAT 5 Shielded Twisted Pair STP cable with BER less than 10e 10 RJ 45 Ethernet 1000 Copper 1000Base T This product has been tested and found to comply with the limits for Class 1 laser devices for IEC825 EN60825 and 21CFR1040 specifications Important The GLC2 supports the Star Channel 1 Gbps for faster FPGA upgrades and is Restriction of Hazardous Substances RoHS 6 6 compliant Th...

Page 43: ...d See Applying Power and Verifying Installation for definitions 3 Gigabit Ethernet Interface Gigabit Ethernet GE SFP modules 1000Base SX 1000Base LX and 1000Base T interfaces are supported depending on the SFP module installed 4 Quad Gigabit Ethernet Line Card QGLC The QGLC is a 4 port Gigabit Ethernet line card that installs directly behind its associated packet processing card to provide network...

Page 44: ...l duplex up to 100 meters of CAT 5 Shielded Twisted Pair STP cable with BER less than 10e 10 RJ 45 Ethernet 1000 Copper 1000Base T This product has been tested and found to comply with the limits for Class 1 laser devices for IEC825 EN60825 and 21CFR1040 specifications Important The QGLC supports the Star Channel 1 Gbps for faster FPGA upgrades and is Restriction of Hazardous Substances RoHS 6 6 c...

Page 45: ...erfaces are supported depending on the SFP module installed 4 10 Gigabit Ethernet Line Card XGLC The XGLC supports higher speed connections to packet core equipment increases effective throughput between the ASR 5000 and the packet core network and reduces the number of physical ports needed on the ASR 5000 The XGLC 10G Ethernet is a full height line card unlike the other line cards which are half...

Page 46: ...her numbered slot s configuration is erased and then duplicated from the lower numbered slot The lower numbered top slot retains all other configuration settings While side by side redundancy is configured all other configuration commands work as if the side by side slots were top bottom slots Configuration commands directed at the bottom slots either fail with errors or are disallowed When you un...

Page 47: ...IEC825 EN60825 and 21CFR1040 specifications Important The following shows the front panel of the XGLC identifying its interfaces and major components Figure 17 10 Gigabit Ethernet Line Card XGLC ASR 5000 Installation Guide 31 ASR 5000 Hardware Platform Overview 10 Gigabit Ethernet Line Card XGLC ...

Page 48: ...el functionality frame size and bit rate are the same as STM 1 SONET offers an additional basic unit of transmission STS 1 Synchronous Transport Signal 1 operating at 51 84 Mbps exactly one third of an STM 1 STS 3c The OLC2 concatenates three STS 1 OC 1 frames to provide transmission speeds up to 155 52 Mbps with payload rates of 149 76 Mbps and overhead rates of 5 76 Mbps The OLC2 optical fiber l...

Page 49: ...ale connector ATM POS OC 3 SM IR 1 Single mode Optical Fiber Fiber Types Multi mode optical fiber Wavelength 1310 nm Core Size 62 5 micrometers Cladding Diameter 125 micrometers Range Short 2 kilometers Min Max Tx Power 19 dBm 14 dBm Rx Sensitivity 30 dBm Multi mode Fiber LC duplex female connector ATM POS OC 3 Multi Mode Multi mode Optical Fiber The OLC2 supports the Star Channel 1 Gbps for faste...

Page 50: ...otifies the system to safely power down the card prior to its removal 2 Card Level Status LEDs Show the status of the card 3 Port connectors Fiber LC duplex female connector 4 Port Level Status LEDs Show the status of a port 5 Line Card Label Identifies the type of SFP modules and cabling supported OLC2 OC 3 STM 1 Single Mode OLC2 OC 3 STM 1 Multi Mode 6 Channelized Line Card CLC2 The CLC2 is also...

Page 51: ...ing Diameter 125 micrometers Range Intermediate 21 kilometers Attenuation 0 25 dB KM Min Max Tx Power 15 dBm 8 dBm Rx Sensitivity 28 dBm Single mode Fiber LC duplex female connector Channelized STM 1 OC 3 SM IR 1 Single mode Optical Fiber Fiber Types Multi mode optical fiber Wavelength 1310 nm Core Size 62 5 micrometers Cladding Diameter 125 micrometers Range Short 2 kilometers Min Max Tx Power 19...

Page 52: ... duplex female connector 4 Port Level Status LEDs Show the status of a port 5 Line Card Label Identifies the type of SFP modules and cabling supported CLC2 OC 3 STM 1 Single Mode CLC2 OC 3 STM 1 Multi Mode 6 The Channelized Line Card CLC2 was developed in compliance with the following standards ITU T Recommendation G 704 Synchronous Frame Structures Used at 1544 6312 2048 8448 and 44736 kbps Hiera...

Page 53: ...bility Targets March 2000 ITU T Recommendation G 832 Transport of SDH elements on PDH networks Frame and multiplexing structures October 1998 ITU T Recommendation G 957 Optical interfaces for equipment and systems relating to the Synchronous Digital Hierarch March 2006 ITU T Recommendation I 431 Primary Rate User Network Interface Layer 1 Specification March 1993 ITU T Recommendation O 150 General...

Page 54: ...ng lock mechanism notifies the system to migrate various processes on the card prior to its removal The following figure shows how the card interlock switch works in conjunction with the ejector lever Figure 20 Card Interlock Switch in the Lever locked Position Card Identifiers The table below cross references ASR 5000 application and line cards by acronym label variant and Cisco part identifier P...

Page 55: ...by GLC2 GELC Ethernet 1000 Line Card with SX MM Short Haul SFP Ethernet 1000 SX GLC2 GLC2 Ethernet 1000 Line Card with LX SM SFP Ethernet 1000 LX with copper SFP Ethernet 1000 T with SX MM Short Haul SFP Ethernet 1000 SX QGLC QGLC 4 Port Ethernet 1000 Line Card with LX SM SFP Ethernet 1000 LX with copper SFP Ethernet 1000 T with SX MM Short Haul SFP Ethernet 1000 SX QGLC QGLC Rev2 4 Port Ethernet ...

Page 56: ...Variant Label Acronym Descriptor with MM SFP OLC2 OC 3 STM 1 OLC2 Optical 4 port ATM Line Card with SM SFP ASR 5000 Installation Guide 40 ASR 5000 Hardware Platform Overview Card Identifiers ...

Page 57: ...hysical installation of the chassis It includes the following sections Chassis Components page 42 Installation at a Glance page 43 Required Tools and Equipment page 44 Site Prerequisites page 45 Protecting Against Electro static Discharge page 45 Federal Communications Commission Warning page 46 ASR 5000 Installation Guide 41 ...

Page 58: ...e following 1 8 17 and 24 These are intentionally left uncovered for the initial installation of system components 1 Mounting brackets Supports installation in a standard 19 inch rack or telecommunications cabinet Standard and mid mount options are supported In addition each bracket contains an electro static discharge jack for use when handling equipment 2 Upper fan tray Draws air up through the ...

Page 59: ...allation process for the chassis Unpacking instructions are not provided in this document Please refer to the Unpacking the ASR 5000 Chassis document shipped with the system for information and instructions on this topic The chassis and cards are shipped separately Note Unpack the chassis and cards Determine which chassis mounting option to use standard or mid mount Install the chassis into a stan...

Page 60: ...tic Discharge section that follows During installation maintenance and or removal wear grounding wrist and or heel straps to avoid ESD damage to the components Failure to do so could result in damage to sensitive electronic components and potentially void your warranty Caution Equipment The following equipment is necessary to install the chassis and verify that it is ready for configuration Standa...

Page 61: ...ures and relative humidity specified in the Technical Specifications chapter HVAC capacity requirements will vary based on the system configuration and associated power draw as well as the operational characteristics of other equipment installed at the site Clearance Adequate clearance must be maintained at the front and rear of the ASR 5000 chassis to assure proper air flow and allow maintenance ...

Page 62: ...er of this document Important Figure 22 Location of Chassis ESD Jacks Federal Communications Commission Warning This device complies with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules and Regulations Operation is subject to the following two conditions ASR 5000 Installation Guide 46 Installation Procedure Overview Federal Communications Commission Warning ...

Page 63: ...use harmful interference to radio and television communications Operation of this equipment in a residential area is likely to cause interference in which case the user will be required to correct the interference at his or her own expense Modifications to this product not authorized by Cisco could void the FCC approval and negate your authority to operate the product Shielded cables must be used ...

Page 64: ...ASR 5000 Installation Guide 48 Installation Procedure Overview Laser Notice ...

Page 65: ...signed for installation in a standard 19 inch 48 26 cm equipment rack Additional rack hardware such as extension brackets may be used to install the chassis in a standard 23 inch 58 42 cm rack Each chassis is 24 50 inches 62 23 cm high This equates to roughly 14 Rack Mount Units RMUs 1 RMU 1 75 in 4 45 cm You can mount a maximum of three chassis in a standard 48 RMU 7 ft equipment rack or telco ca...

Page 66: ...ver system components Total air flow exiting the chassis is approximately 275CFM 7 8 cubic meters minute Low fan speed 565CFM 16 cubic meters minute High fan speed The upper fan tray pulls the heated air up through the chassis The heated air exits through the side and rear exhaust vents located at the top of the chassis Figure 23 System Airflow and Ventilation Proper ventilation and cooling must a...

Page 67: ...the following recommendations before proceeding If available use an equipment lift to lift and move the chassis during the installation process If no lift is available reduce the weight according to the instructions in the Reducing the Weight of the Chassis Prior to Installation on page 54 These procedures reduces the weight of the chassis to approximately 125 lbs 56 7 kg At least two people are r...

Page 68: ...sections are secured together for shipping via four locking mechanisms located near the bottom corners of the container ASR 5000 Installation Guide 52 Chassis Installation Unpacking the ASR 5000 Chassis ...

Page 69: ... printed instructions that come with the shipment for detailed unpacking procedures Important Figure 24 ASR 5000 Shipping Container ASR 5000 Installation Guide 53 Chassis Installation Unpacking the ASR 5000 Chassis ...

Page 70: ...tive electronic components and potentially void your warranty Caution Reducing the Weight of the Chassis Prior to Installation To make the installation process easier you can reduce the weight of the chassis prior to installation by removing the upper and lower fan trays and the PFUs Follow the instructions below to safely remove these components prior to installation During installation maintenan...

Page 71: ...ld easily slide out of the chassis Place it to the side for re installation later To avoid personal injury and or damage to the fan tray be sure to support the weight of the fan tray from its front and back as you slide it completely out of the chassis Vorsicht beim Herausziehen der Luefter Schublade um eine Beschaedigung des Moduls und eventuelle Verletzungen zu vermeiden sollte diese hinten und ...

Page 72: ...ray toward you using the handle The fan tray should easily slide out of the chassis Place it to the side for re installation later To avoid personal injury and or damage to the fan tray be sure to support the fan tray s weight from its front and back as you slide it completely out of the chassis Vorsicht beim Herausziehen der Luefter Schublade um eine Beschaedigung des Moduls und eventuelle Verlet...

Page 73: ...the Chassis on page 57 or Mid Mount Installation of the Chassis on page 58 based on the mounting option you are using Flush Mount Installation of the Chassis Follow the instructions below to perform the flush mount installation of the chassis Step 1 Position the chassis in the equipment rack so that the flanges of the mounting brackets at the front of the chassis are flush with the mounting rails ...

Page 74: ...ructions below to perform the mid mount installation of the system Step 1 On the side of the chassis unfasten the eight Phillips 2 screws that secure the mounting bracket to the chassis Step 2 Place the mounting bracket over the middle set of mounting holes on the side of the chassis and secure it to the chassis with the screws you removed in step 1 ASR 5000 Installation Guide 58 Chassis Installat...

Page 75: ... brackets are flush with the mounting rails of the equipment rack Step 5 Mount the chassis to the rails of the equipment rack with the hardware that was supplied with the equipment rack Begin with the two bottom holes and work your way up until all holes on each flange are secured ASR 5000 Installation Guide 59 Chassis Installation Mid Mount Installation of the Chassis ...

Page 76: ...at the chassis is properly grounded prior to installing any chassis sub components or cards The chassis and the equipment rack or telecommunications cabinet that it is installed in must be connected to the same ground Failure to properly ground the chassis could result in personal injury and or damage to the chassis and its components Caution ASR 5000 Installation Guide 60 Chassis Installation Gro...

Page 77: ...s Ground Terminals Table 25 Terminal and Cable specifications Description Item Ground Terminal 2 hole lug 0 186 inch posts spaced 0 630 inch on center The method of connection is chassis lug flat washer nut 3 8 inch The nut s must be torqued to 50 in lb 5 65 N m 1 Ground Cable Cable length Not more than 70 feet 21 336 meters one way Cable size 6 AWG minimum stranded copper 2 ASR 5000 Installation ...

Page 78: ...uts and washers you removed in step 4 The nuts should be torqued to 50 in lb 5 65 N m Step 7 Repeat step 2 through step 6 to connect the second ground cable to the chassis ground terminal on the lower right corner at the rear of the chassis next to Power Filter Unit 2 Step 8 If you took steps to reduce the weight of the chassis prior to installation refer to the instructions in the Re Installing C...

Page 79: ...are labeled from left to right Power Filter Unit 1 and Power Filter Unit 2 b Slide the PFU assembly into the PFU bay labeled Power Filter Unit 1 until it is flush against the chassis c Use a Phillips 2 screwdriver to tighten each of the four screws on the PFU to secure it to the chassis d Re install the second PFU in the PFU bay labeled Power Filter Unit 2 by repeating step b and step c Step 2 Re ...

Page 80: ...is b Slowly slide the fan tray into the chassis along the guides using its handle until it is seated firmly in the chassis and can go no further c Verify that the particulate filter is securely in place Its front should be flush with the front of the fan tray assembly and its tab should be lowered to keep it in place ASR 5000 Installation Guide 64 Chassis Installation Re Installing Chassis Sub com...

Page 81: ... bezel align it over the bezel mounts that protrude from the fan tray bay cover and snap it in place Step 3 Re install the upper fan tray a Hold the front of the fan tray by its sides and align it with the upper fan tray bay of the chassis The upper fan tray bay is located at the upper front of the chassis b Slowly slide the fan tray into the chassis along the guides until its face plate is firmly...

Page 82: ...n it over the bezel mounts that protrude from the face of the fan tray and snap it in place Step 4 Proceed to the Application Card Installation chapter ASR 5000 Installation Guide 66 Chassis Installation Re Installing Chassis Sub components ...

Page 83: ...the following sections Chassis Slot Numbering and Assignments page 67 Installing Application Cards page 69 Chassis Slot Numbering and Assignments The chassis has 16 front loading slots that host application cards This allows the installation of redundant components and provides ample room for expanding the system Chassis slots are labeled 1 through 16 from left to right Figure 26 Chassis Front Slo...

Page 84: ...ap or assign duplicate IP address ranges in different contexts The minimum recommended redundancy for packet services cards is one redundant card for up to 13 active cars The following table details the specific ASR 5000 chassis slot assignments for each of the above card types Table 26 Application Card Slot Assignments Description Chassis Slot Number s Application Card Type Primary SMC 8 System M...

Page 85: ...ssing card For additional information about RCCs refer to Line Card Installation in this guide Important Recommended Minimum Chassis Configuration The recommended minimum chassis configuration for application cards including redundancy is as follows Card State Card Slot Number Active SMC 8 Standby SMC 9 Active PSC2 or PSC3 2 and 4 see Note 1 2 3 and 4 see Note 2 Standby PSC2 or PSC3 11 see Notes 1...

Page 86: ... to loosen the screws at the top and bottom of the blanking panel b Holding the screws on the blanking panel pull the blanking panel away from the chassis to expose the chassis slot Step 4 Slide the interlock switch on the card fully downward and flip both ejector levers fully outward and away from the front panel Step 5 Properly support the weight of the card and align it with the upper and lower...

Page 87: ...he chassis upper and lower card mounts for the slot Step 7 Slide the interlock switch on the front panel of the application card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important ASR 5000...

Page 88: ...ot occupied by an application card Leere Steckplaetze muessen mit der dafuer vorgesehenen Abdeckplatte geschlossen werden um die Luftzirkulation innerhalb des Geraets zu gewaehrleisten und um einen elektrischen Schlag zu vermeiden a Position the blanking panel over the unused chassis slot b Use a Phillips 2 screwdriver to tighten the screws at the top and bottom of the blanking panel to secure the...

Page 89: ... page 73 Line Card Redundancy page 76 Recommended Minimum Chassis Configuration page 78 Installing Half Height Line Cards page 79 Installing the 10 Gigabit Ethernet Line Card XGLC page 81 Chassis Slot Numbering and Assignments The chassis has 32 rear loaded slots for line cards This allows for the installation of redundant components and provides ample space for expanding the system ASR 5000 Insta...

Page 90: ...ring for other installed half height cards is maintained 17 to 32 and 33 to 48 regardless of the number of installed XGLCs Important The following table shows the front slot numbers and their corresponding rear slot numbers Table 27 Front and Rear Slot Numbering Relationship Slot Number Position 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Front 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 Rear Top S...

Page 91: ... packet processing cards Each card provides four LC duplex ports that accept small SFP modules and supports either single mode or multi mode fiber optic cable Channelized STM 1 OC 3 Line Cards CLC2 Four port CLC2s are installed directly behind their corresponding packet processing cards The CLC2 provides four LC duplex ports The ports accept one of two types of Small Form factor Pluggable SFP modu...

Page 92: ...corresponding packet processing card Each packet processing card can support up to two OLC2s The active card is installed in the upper rear chassis slot The redundant card is installed in the lower rear chassis slot 17 through 23 26 through 39 or 42 through 48 Optical ATM OLC2 Resides directly behind its corresponding packet processing card Each packet processing card can support up to two CLC2s T...

Page 93: ... is active The packet processing cards behind a pair of redundant XGLCs must always be in Active mode Important Requirement Summary There must be a direct connection to a packet processing card behind each side by side redundant XGLC pair Configure the XGLC Ethernet line cards in a chassis as redundant pairs with cards in the following adjacent slots 17 18 19 20 21 22 23 26 SPIOs 24 and 25 are ski...

Page 94: ...hassis Configuration Line Card Slot Number Associated Interface Card Application Card Slot Number Application Card 24 SPIO 8 SMC 40 RCC 25 SPIO 9 Redundant SMC 41 RCC 18 and 34 FLC2 or QGLC 2 PSCA PSC2 PSC3 or PPC Note that for Release 9 0 only PDSN and HA are supported on the PPC Note that for Release 10 0 only PDSN HA and GGSN are supported on the PPC Redundant FLC2 or QGLC 17 and 32 XGLC N A No...

Page 95: ...Determine which chassis slot to install the card in based on the information in Chassis Slot Numbering and Assignments on page 73 Step 3 Remove the blanking panel covering the slot if one is installed a Use a Phillips 2 screwdriver to loosen the screws at the top and bottom of the blanking panel b Hold the screws on the blanking panel and pull the blanking panel away from the chassis to expose the...

Page 96: ...he chassis upper and lower card mounts for the slot Step 7 Slide the interlock switch on the front panel of the line card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important ASR 5000 Instal...

Page 97: ...Gigabit Ethernet interface for network connectivity There are two versions of the XGLC XGLC SR accepts a 10GBase SR module that drives optical fiber with a center wavelength of 850nm terminated by an LC optical connector The module can drive optical signals up to 300 meters using 50 125um fiber MMF and up to 33 meters using 62 5 125um fiber MMF XGLC LR accepts a 10GBase LR module that drives optic...

Page 98: ...per and lower card guides of the chassis slot Gently slide the card into the slot until the levers touch the chassis frame Step 4 Push the ejector levers inward firmly until the card is firmly seated in the chassis midplane and the ejector levers can be pushed in no further Press firmly on the card s faceplate to ensure that it is fully seated The card s front panel should be flush against the cha...

Page 99: ...ighten the screws at the top and bottom of the front panel to secure the card to the chassis Step 7 Repeat step 1 through step 10 for every other line card that to be installed Step 8 Proceed to the appropriate chapter for information on connecting data cables to the line cards ASR 5000 Installation Guide 83 Line Card Installation Installing the XGLC ...

Page 100: ...ASR 5000 Installation Guide 84 Line Card Installation Installing the XGLC ...

Page 101: ... EN60825 and 21CFR1040 specifications Important This chapter includes the following sections SPIO Interfaces page 85 Connecting to the Management LAN page 88 Connecting to the Serial Console Port page 91 Connecting to a BITS Timing Source page 95 Connecting to the CO Alarm Interface page 97 SPIO Interfaces The SPIO is available with the following types of interfaces Two Gigabit Ethernet fiber opti...

Page 102: ...nagement LAN Optical fiber Small Form factor Pluggable SFP 1 1 Gigabit Ethernet interface for connecting to management LAN Optical fiber Small Form factor Pluggable SFP 2 2 10 100 1000 Ethernet interface for connecting to management LAN RJ 45 Ethernet 1 3 10 100 1000 Ethernet for connecting to management LAN RJ 45 Ethernet 2 4 RS 232 interface for local administration of the system RJ 45 Console 5...

Page 103: ...sion The figure and table that follow provide information on the various interfaces in this version of the SPIO Figure 29 SPIO BITS 3 Pin Interface Callouts Table 31 SPIO 3 Pin BITS Interface Descriptions Description Connector Type Label Item Gigabit Ethernet interface for connecting to management LAN Optical fiber Small Form factor Pluggable SFP 1 1 Gigabit Ethernet interface for connecting to ma...

Page 104: ...sical connection to the management LAN the fiber optic SFP and the Ethernet RJ 45 interfaces When you cable these interfaces make sure you do only one of the following Both SFP interfaces Both Ethernet interfaces SFP 1 and Ethernet 2 SFP 2 and Ethernet 1 Be sure to label the interface cables with their destination prior to connecting them to the SPIO This will assure proper reconnection should the...

Page 105: ... this equipment Invisible laser radiation may be emitted from the aperture of the port when no cable is connected Avoid exposure to laser radiation and do not look into open apertures Be sure to keep the cover on the interface when it is not in use Laser Klasse 1 nur speziell ausgebildetes Personal darf dieses Geraet warten Nicht in den Laser schauen um Augenverletzungen zu vermeiden Nicht genutzt...

Page 106: ...irements and ensure compliance with Radiated Emissions Criteria you must use shielded twisted pair STP copper cable and ensure that it is properly terminated at both ends Important The 1000Base TX RJ 45 management ports of the SPIO are suitable for connection to intra building or unexposed wiring or cabling only These intra building ports MUST NOT be metallically connected to interfaces that conne...

Page 107: ...n the card is connected Activity This green LED shows when data is transmitted or received The LED is illuminated when data is passing through the interface To use the RJ 45 interfaces simply plug the Ethernet cable into either the Ethernet 1 or Ethernet 2 interface Connecting to the Serial Console Port The Console port is an RJ 45 RS 232 interface that provides access to the system s command line...

Page 108: ...nd CTS 1 Input Data set Ready DSR 2 Input Receive Data RX 3 N A Signal Ground SGND 4 Output Ready to Send RTS 5 Output Transmit Data TX 6 Input Data Carrier Detect DCD 7 Output Data Terminal Ready DTR 8 DB 9 to RJ 45 Adapter SPIOs are shipped with an RJ 45 to RJ 45 serial cable and an RJ 45 to DB 9 adapter The DB 9S conductor on the adapter is female If you use the cable and adaptor together refer...

Page 109: ...SPIO Console Port Interface Signal DB 9S Pin RJ 45 Pin RJ 45 Pin Signal Type Signal RTS 7 1 1 Input Clear to Send CTS DTR 4 2 2 Input Data Set Ready DSR TxD 3 3 3 Input Receive Data RxD SGND 5 4 4 N A Signal Ground SGND CTS 8 5 5 Output Ready To Send RTS RxD 2 6 6 Output Transmit Data TxD DCD 1 7 7 Input Data Carrier Detect DCD DSR 6 8 8 Output Data Terminal Ready DTR ASR 5000 Installation Guide 9...

Page 110: ...1 Type B connector 1 Table 36 USB to DB 9 Adapter DB 9 Pinouts Console Port Signal type Signal Description DB 9 Pin Unused Input Data Carrier Detect DCD 1 TxD Input Receive Data RxD 2 RxD Output Transmit Data TxD 3 Unused Output Data Terminal Ready DTR 4 Ground Ground Signal Ground SGND 5 Unused Input Data Set Ready DSR 6 Unused Output Request To Send RTS 7 Unused Input Clear To Send CTS 8 Unused ...

Page 111: ...nnect one end of the RJ 45 to RJ 45 cable into the DB 9 adapter Step 3 Connect the DB 9S female end of the cable assembly to the DB 9P male serial port on the workstation Step 4 Configure the communications application on the workstation to support the following settings 115200 bps 8 data bits no parity 1 stop bit no flow control Connecting to a BITS Timing Source The SPIO can be optionally equipp...

Page 112: ...R 5000 Important BITS E1 BNC Interface The BNC version of the SPIO employs a 75 ohm coaxial BNC connector that accepts an analog E1 BITS signal The following figure shows the BITS BNC timing interface Figure 36 SPIO E1 BITS BNC Pinout Use 75 ohm coaxial cable RG 59 U between the BITS and the SPIO BNC interface to carry the E1 signal At the SPIO terminate the cable with a 75 ohm BNC male connector ...

Page 113: ... Minor Alarm This alarm is triggered when a high temperature is detected on a card causing the fan tray to switch its fans to high speed Major Alarm This alarm is triggered by a Hardware failure that places a card in an off line state Power filter unit failure or removal from the chassis Failure of one or more fans on either the upper or lower fan tray Fan tray failure or either fan tray assembly ...

Page 114: ...oot 2 4 meter CO alarm cable shipped with the chassis supports redundant SPIO card installations This Y cable has two Molex connectors on one end that are keyed to fit into the CO Alarm interfaces in one direction only Each connector mates with one of the side by side SPIO cards On the opposite end is a 9 pin terminal block that you can mount to the telco cabinet or equipment rack frame ASR 5000 I...

Page 115: ...rmally closed 1 Black 1 Major Alarm Common 2 Orange 2 Major Alarm Normally open 3 Red 3 Minor Alarm Normally closed 4 Brown 4 Minor Alarm Common 5 Yellow 5 Minor Alarm Normally open 6 Green 6 Critical Alarm Normally closed 7 Blue 7 Critical Alarm Common 8 Violet 8 Critical Alarm Normally open 9 Gray 9 Unused Not equipped Not wired 10 ASR 5000 Installation Guide 99 Cabling the Switch Processor Inpu...

Page 116: ...ace only Type 2 or Type 4 ports as described in GR 1089 CORE Issue 5 and requires isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Important Central Office Alarm Wiring Example The following figure depicts how the dry contact relays can each control up to two external alarm indicat...

Page 117: ...the green LED is illuminated If an alarm relay is energized the NO normally open contact closes and the red LED is illuminated ASR 5000 Installation Guide 101 Cabling the Switch Processor Input Output Line Card Central Office Alarm Wiring Example ...

Page 118: ...ASR 5000 Installation Guide 102 Cabling the Switch Processor Input Output Line Card Central Office Alarm Wiring Example ...

Page 119: ... includes the following section FLC2 Interfaces page 103 FLC2 Interfaces The Fast Ethernet Line Card FLC2 Ethernet 10 100 has eight RJ 45 interfaces as shown in the figure below Each of these is an auto sensing 10Base T 100Base TX Ethernet interface that terminates a shielded twisted pair STP copper cable The interfaces are labeled 1 through 8 from top to bottom ASR 5000 Installation Guide 103 ...

Page 120: ...n GR 1089 CORE Issue 5 and require isolation from the exposed OSP cabling The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Important Figure 41 Fast Ethernet Line Card Interface Connectors The system uses these interfaces to connect to other elements in the packet data network Each of these interfaces is equipped with tw...

Page 121: ...e 5 RX 6 Not applicable 7 Not applicable 8 RX Receive Data TX Transmit Data Be sure to label the interface cables with their destinations prior to connecting them to the FLC2 This will assure proper reconnection should the card need to be serviced Important To cable the FLC2 simply plug an STC Ethernet cable from a network device into the desired port ASR 5000 Installation Guide 105 Cabling the Fa...

Page 122: ...ASR 5000 Installation Guide 106 Cabling the Fast Ethernet 10 100 Line Card FLC2 Interfaces ...

Page 123: ... These cards support 802 3z compliant Gigabit Ethernet interface s which connect the chassis to other elements in the packet data network This chapter includes the following sections Gigabit Ethernet Line Card GLC2 page 108 Quad Gigabit Ethernet Line Card QGLC page 109 RJ 45 SFP Module Detail page 111 Cabling the Optical SFP Interface page 113 10 Gigabit Ethernet Line Card XGLC page 114 Cabling th...

Page 124: ...ng SFP modules are hot pluggable Important Table 40 SFP Modules Supported by the GLC2 Cable Specifications Interface Type Card Identification Module Type Fiber Type Multi mode fiber MMF 850 nm wavelength Core Size microns Range 62 5 902 23 feet 275 meters 50 1640 42 feet 500 meters Minimum Tx Power 9 5 dBm Rx Sensitivity 17 dBm Fiber LC duplex female connector Ethernet 1000 SX 1000Base SX ASR 5000...

Page 125: ...lded twisted pair cable and ensure that it is properly terminated at both ends RJ 45 Ethernet 1000 Copper 1000Base T The SFP interface is only certified to work with SFP transceiver modules purchased from Cisco for use with the GLC2 Important Class 1 Laser Compliance Notice Because of the optical SFP interface this product has been tested and found to comply with the limits for Class 1 laser devic...

Page 126: ...t mix and match SFP modules in one QGLC Important Table 41 SFP Modules Supported by the QGLC Cable Specifications Interface Type Card Identification Module Type Fiber Type Multi mode fiber MMF 850 nm wavelength Core Size microns Range 62 5 902 23 feet 275 meters 50 1640 42 feet 500 meters Minimum Tx Power 9 5 dBm Rx Sensitivity 17 dBm Fiber LC duplex female connector Ethernet 1000 SX 1000Base SX A...

Page 127: ...iated Emissions Criteria you must use shielded twisted pair cable and ensure that it is properly terminated at both ends RJ 45 Ethernet 1000 Copper 1000Base T The SFP interface is only certified to work with SFP transceiver modules purchased from Cisco for use with the QGLC Important Because of the optical SFP interface this product has been tested and found to comply with the limits for Class 1 l...

Page 128: ...he addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring Important Figure 45 RJ 45 Interface Pinout Table 42 RJ 45 Interface Pinout 1000Base Tx 1Gbps Cat5 Pin BI DA 1 BI DA 2 BI DB 3 BI DC 4 BI DC 5 BI DB 6 BI DD 7 BI DD 8 RX Receive Data TX Transmit Data BI BI directional data DA DB DC DD Data Pair A B C and D The following lig...

Page 129: ...f the port when no cable is connected Avoid exposure to laser radiation and do not look into open apertures Be sure to keep the cover on the interface when it is not in use Laser Klasse 1 nur speziell ausgebildetes Personal darf dieses Geraet warten Nicht in den Laser schauen um Augenverletzungen zu vermeiden Nicht genutzte Buchsen mit der entsprechenden Kappe verschliessen Step 1 Remove the cover...

Page 130: ...d The XGLC uses industry standard SFP transceiver modules to support various fiber types as required The following diagram shows the XGLC s single SFP interface Figure 46 XGLC Fiber Optic Interface ASR 5000 Installation Guide 114 Cabling the Gigabit Ethernet Line Cards 10 Gigabit Ethernet Line Card XGLC ...

Page 131: ...installed directly behind their respective PSCs PSC2s or PPCs but they are not required behind any redundant packet processing cards those operating in Standby mode The following Light Emitting Diodes LEDs are provided on the Gigabit Ethernet line cards Link This green LED shows whether or not the line card is connected to the network The LED is illuminated when the card is connected Activity This...

Page 132: ...er radiation and do not look into open apertures Be sure to keep the cover on the interface when it is not in use Laser Klasse 1 nur speziell ausgebildetes Personal darf dieses Geraet warten Nicht in den Laser schauen um Augenverletzungen zu vermeiden Nicht genutzte Buchsen mit der entsprechenden Kappe verschliessen Step 1 Remove the cover from the SFP interface Step 2 Insert the optical cable fro...

Page 133: ...ts in the packet data network The type of optical fiber interface on the line card is dictated by the Small Form factor Pluggable SFP transceiver modules installed on the line card The OLC2 supports two versions of SFP modules SFP modules are hot pluggable Table 44 SFP Modules Supported by the OLC2 Optical ATM Line Card Cable Specifications Interface Type Card Identification Module Type Fiber Type...

Page 134: ...ith SFP transceiver modules purchased from Cisco for use with the OLC2 Important Because of the optical SFP interface this product has been tested and found to comply with the limits for Class 1 laser devices for IEC825 EN60825 and 21CFR1040 specifications Important The following figure shows the optical interface labelled ATM POS OC 3 for the optical ATM line card Each SFP fiber interface is equi...

Page 135: ...he interface when it is not in use Laser Klasse 1 nur speziell ausgebildetes Personal darf dieses Geraet warten Nicht in den Laser schauen um Augenverletzungen zu vermeiden Nicht genutzte Buchsen mit der entsprechenden Kappe verschliessen Step 1 To ensure full connectivity use your thumb to firmly press the SFP transceiver module into its socket on the front panel of the card Step 2 Remove the cov...

Page 136: ...ASR 5000 Installation Guide 120 Cabling the Optical ATM Line Cards Cabling the Optical SFP Interface ...

Page 137: ...eiver modules The type of optical fiber interface on the line card is dictated by the SFP modules installed on the card The SFP modules are hot pluggable Table 45 SFP Modules Supported by the CLC2 Cable Specifications Interface Type Card Identification Module Type Fiber Types Single mode optical fiber Wavelength 1310 nm Core Size 9 micrometers Cladding Diameter 125 micrometers Range Intermediate 2...

Page 138: ...nterface is only certified to work with SFP transceiver modules purchased from Cisco for use with the CLC2 Important Because of the optical SFP interface this product has been tested and found to comply with the limits for Class 1 laser devices for IEC825 EN60825 and 21CFR1040 specifications Important The following figure shows the LC connectors for the CLC2 Each SFP fiber interface provides both ...

Page 139: ...face when it is not in use Laser Klasse 1 nur speziell ausgebildetes Personal darf dieses Geraet warten Nicht in den Laser schauen um Augenverletzungen zu vermeiden Nicht genutzte Buchsen mit der entsprechenden Kappe verschliessen Step 1 To ensure full connectivity use your thumb to firmly press the SFP transceiver module into its socket on the front panel of the card Step 2 Remove the cover from ...

Page 140: ...ASR 5000 Installation Guide 124 Cabling the Channelized Line Cards Cabling the Optical SFP Interface ...

Page 141: ...tions Each chassis supports one or two 165 amp PFUs The following table describes the power requirements for the chassis These requirements are guidelines to assure that the cabling for your system meets safety requirements Note Table 46 Chassis Power Requirements Value Characteristic Maximum range 40VDC to 60VDC Nominal range 48VDC to 60 VDC Input Voltage 165A 48 VDC TUV Rated Peak Current Load 5...

Page 142: ...00 installation with 3 PSCs 2 SMCs 2 SPIOs 2 RCCs and 4 Ethernet 1000 line cards is as follows 250W x 3 130W x 2 20W x 2 13 5W x 4 800W 1934W Power Cable Requirements You can install up to three chassis in an equipment rack or telecommunications cabinet Typically power cabling is run from the office Power Distribution Frame PDF to a Power Distribution Panel PDP installed in the rack or cabinet and...

Page 143: ... voltage drop of 0 6 volts PDF to Fuse Panel Assuming an 18 foot 5 5 meter loop length each cable between the PDP and the chassis must be the equivalent of 83 690 circular mils 1 AWG or greater Use high flex cable Calculations assume a 0 3 volt drop from the PDF to the PDP and 0 3 volt drop from the fuse panel to the chassis This is a total voltage drop of 0 6 volts The following figure and table ...

Page 144: ...Figure 49 PFU Wiring Diagram ASR 5000 Installation Guide 128 Cabling the Power Filter Units Power Cable Requirements ...

Page 145: ...he cable ends with a Panduit crimp tool part number CT 920 die color green P37 CD 920 1 The plastic terminal cover must be installed over power and return lugs at all times Die angeschlossenen Kabelschuhe muessen mit der Plastikabdeckung gesichert sein 1 Power Cables PDP to Chassis Cable length Not more than 9 feet 2 7 meters one way Voltage drop 0 3v Cable size 1 AWG or greater 2 Power Cables PDF...

Page 146: ...the plastic cover from the power terminals with a 2 Phillips head screw driver Step 3 Use a 9 16 inch nut driver or socket wrench to remove the nuts and the lock washers from each of the four terminals Step 4 Connect the lug attached to the power return cable to the PFU a Insert the lug over the two terminals labeled RTN These are the two top terminals on the PFU b Secure the lug to the RTN termin...

Page 147: ...rminal cover To avoid the risk of potential damage to the system never operate the chassis without the plastic terminal cover installed Make sure that the power and return lugs do not protrude past the edge of the plastic terminal covers Any portion of the lug that is exposed must be covered with heat shrink tubing Caution Step 7 Repeat step 1 through step 6 for the PFU installed in the bay labele...

Page 148: ...ASR 5000 Installation Guide 132 Cabling the Power Filter Units Connecting the PFU to the Power Source ...

Page 149: ... physically installed The system has also been cabled to interoperate with management and traffic networks Important This chapter includes the following sections Understanding the System Boot Process page 133 Applying Power to the Chassis page 136 Verifying the Installation page 137 Completing Initial System Configuration page 167 Understanding the System Boot Process Before you apply power to the...

Page 150: ...ore the SMCs are the first cards to boot and their LEDs are the first to light up Once the system confirms that cards are located in slots 8 and 9 power is quickly applied to the SPIOs in slots 24 and 25 Step 2 During the startup process each card performs a series of Power On Self Tests POSTs to ensure that the hardware is ASR 5000 Installation Guide 134 Applying Power and Verifying the Installat...

Page 151: ...tandby mode Note that the redundant card for an XGLC in slot 17 would be installed in slot 32 Use only the upper slot number when referring to this card Installed line cards remain in ready mode until their corresponding packet processing card is made active via configuration Once the packet processing card is active the line card installed in the upper rear chassis slot behind the card is also ma...

Page 152: ...oltage meter on the VDC terminal and the common probe of the meter on the RTN terminal The meter should display a voltage approximately equal to that of power source Step 5 Power on the system PFUs a Optional If the circuit breaker on your PFU is equipped with a locking clip move the clip to the left unlocking the circuit breaker s actuator b Flip the circuit breaker on the PFU to the ON position ...

Page 153: ... that all of the installed components are functioning properly As the system progresses through its boot process some cards may have no immediate LED activity Line cards have sporadic Link and Activity LED activity It is recommended that you allow several minutes to elapse prior to checking the LEDs on the various cards to verify the installation Important Checking the LED on the PFU Each PFU has ...

Page 154: ...Verify that the power source is on and is supplying the correct voltage and sufficient current Check the cables from the power source to the rack for continuity If a fuse panel is installed between the Power Distribution Frame PDF and the chassis verify that the fuses are intact If a fuse panel is installed between the PDF and the chassis check the cables from the fuse panel to the chassis for con...

Page 155: ... Each SMC is equipped with the following LEDs as shown in the following figure Run Fail Active Standby Status Service Busy ASR 5000 Installation Guide 139 Applying Power and Verifying the Installation Checking the LEDs on the SMC s ...

Page 156: ...e SMC s Run Fail LED indicates the overall status of the card This LED is illuminated steady green for normal operation If the LED is not green use the troubleshooting information in the table to diagnose the problem ASR 5000 Installation Guide 140 Applying Power and Verifying the Installation Checking the LEDs on the SMC s ...

Page 157: ...nstructions in this document If all of the above suggestions have been verified it is possible that the SMC is not functional Please contact your service representative SMC Active LED States The Active LED on the SMC indicates that the software is loaded on the card and it is ready for operation For the SMC installed in slot 8 this LED is illuminated green during normal operation For the SMC insta...

Page 158: ...t 8 this LED is off during normal operation If the LED is not green use the troubleshooting information in the table to diagnose the problem Table 52 SMC Standby LED States Troubleshooting Description Color None needed for the SMC in slot 9 If green for the SMC in slot 8 then verify it is installed properly according to the instructions in this document Card is in redundant mode Green Verify that ...

Page 159: ...ing information Card is not receiving power None SMC Service LED States The Service LEDs on the SMCs indicate that the system requires maintenance or service Examples are that the system could not locate a a valid software image at boot up or that a high temperature condition exists This LED is off during normal operation The possible states for this LED are described in the following table Use th...

Page 160: ... devices Green Blinking Green NOTE If you are removing an SMC from the chassis it is recommended that you wait until this LED is off to ensure the integrity of all data being transferred to or from the memory device No maintenance needed The memory devices are not in use None Checking the LEDs on Packet Processing Cards Each packet processing card is equipped with status LEDs as shown in the follo...

Page 161: ...l LED States The packet processing card s Run Fail LED indicates the overall status of the card This LED is illuminated steady green during normal operation If the LED is not green use the troubleshooting information in the table to diagnose the problem ASR 5000 Installation Guide 145 Applying Power and Verifying the Installation Checking the LEDs on Packet Processing Cards ...

Page 162: ...packet processing card is not functional Please contact your service representative PSCA PSC2 PSC3 and PPC Active LED States The Active LED on the packet processing card indicates that the software is loaded on the card and that the card is ready for operation When the system first boots up all installed packet processing cards are booted into standby mode You must then configure the system to des...

Page 163: ...the system to designate which packet processing cards are to serve as redundant components in standby mode and which are to function as active components If the LED is not green use the troubleshooting information in the table to diagnose the problem Table 58 PSCA PSC2 PSC3 and PPC Standby LED States Troubleshooting Description Color The first time power is applied to the system all of the packet ...

Page 164: ...on the SPIO The possible states for all of the SPIO s LEDs are described in the sections that follow Figure 54 SPIO LEDs SPIO Run Fail LED States The SPIO s Run Fail LED indicates the overall status of the card This LED is illuminated steady green for normal operation If the LED is not green use the troubleshooting information in the table to diagnose the problem ASR 5000 Installation Guide 148 Ap...

Page 165: ...n this document If all of the above suggestions have been verified it is possible that the SPIO is not functional Please contact your service representative SPIO Active LED States The Active LED on the SPIO indicates that the software is loaded on the card and that the card is ready for operation For the SPIO installed in chassis slot 24 this LED is steady green during normal operation For the SPI...

Page 166: ...slot 24 check the status of the SMC installed in slot 8 If the SMC in slot 8 is in standby mode it is possible that there is a configuration problem Card is in redundant mode Green Verify that the Run Fail LED is green If so the card is receiving power and POST test results are positive If it is off refer to SPIO Run Fail LED States on page 148 for troubleshooting information Card is not receiving...

Page 167: ...ace If the LED is not green use the troubleshooting information in the table to diagnose the problem During system startup some Link and or Activity LEDs may momentarily illuminate This activity is normal and does not indicate any network link or data transfer status The line card has not yet been initialized and placed into a stable operational state by the system Important Table 63 SPIO Interfac...

Page 168: ...th no errors detected Green Errors were detected during the POSTs It is likely that the errors were logged to the system s command line interface during the boot process Refer to the System Administration Guide for troubleshooting information Card powered with error s detected Red Verify that the POWER LEDs on the PFUs are green If they are not refer to Checking the LED on the PFU on page 137 for ...

Page 169: ...alled properly Card is active Green This is normal prior to configuration Neither the Active or the Standby LED on the card will be on Card is in Ready Mode OR Card is not receiving power OR Card is in Standby Mode None Verify that the Run Fail LED is green If so the card is receiving power and POST test results are positive If it is off refer to Ethernet Line Card Run Fail LED States on page 152 ...

Page 170: ... standby mode Ethernet Line Card Interface Link LED States The Link LEDs associated with a particular network interface on the Ethernet Line Cards show the status of the network link These LEDs are illuminated steady green for normal operation If the LED is not green use the troubleshooting information in the table to diagnose the problem During system startup some Link and or Activity LEDs may mo...

Page 171: ...tion in the following table to diagnose the problem During system startup some Link and or Activity LEDs may momentarily illuminate This activity is normal and does not indicate any current network link or data transfer status The line card has not yet been initialized and placed into a stable operational state by the system Important Table 68 Ethernet Line Card Activity LED States 11 Troubleshoot...

Page 172: ...e the troubleshooting information in the table to diagnose the problem Table 69 Optical ATM Line Card Run Fail LED States Troubleshooting Description Color None needed Card powered with no errors detected Green Errors were detected during the POSTs It is likely that the errors were logged to the system s command line interface during the boot process Refer to the System Administration Guide for tr...

Page 173: ...the packet processing card is made active the line card installed in the upper rear chassis slot behind the packet processing card is also active The line card installed in the lower rear chassis slot behind the packet processing card enters standby mode The possible states for this LED are described in the following table If the LED is not green use the troubleshooting information in the table to...

Page 174: ...slot behind the packet processing card enters standby mode If the LED is not green use the troubleshooting information in the table to diagnose the problem Table 71 Optical ATM Line Card Standby LED States Troubleshooting Description Color None needed for line cards installed in slots 33 through 39 and 42 through 48 after configuration If green for line cards installed in slots 17 through 23 and 2...

Page 175: ...nk States for Optical ATM Line Card Description LED Color LED Illuminates when the port is in a fault condition such as LOS or LOF Off when there is no alarm for this port Red ON OFF Red Alarm Illuminates when the port is receiving a signal indicating a problem at the remote end for example RDI Off when there is no alarm for this port Yellow ON OFF Yellow Alarm ASR 5000 Installation Guide 159 Appl...

Page 176: ...low On OFF Link Card Level LEDs on the Channelized STM 1 OC 3 Line Card Each Channelized line card CLC2 is equipped with card level status LEDs Run Fail Active Standby The location of these LEDs is displayed in the figure below The various states are described in the following three tables Figure 57 Card Level Status LEDs for the Channelized Line Card ASR 5000 Installation Guide 160 Applying Power...

Page 177: ...s Verify that the card is properly installed per the instructions in this document If all of the above suggestions have been verified it is possible that the line card is not functional Please contact your service representative Channelized Line Card Active LED States The Active LED on the channelized line card indicates that the operating software is loaded on the card and that the card is ready ...

Page 178: ...n Guide for information on making the card active Channelized Line Card Standby LED States The Standby LED on the channelized line card indicates that software is loaded on the card and it is serving as a redundant component The installed line cards remain in ready mode until their corresponding packet processing card is activated via configuration While in ready mode the Active LED is off After t...

Page 179: ...Fail LED States on page 161 for troubleshooting information Check the state of the Active LED If it is green the card is in standby mode Checking the Alarm and Link LEDs on the Channelized Line Card 2 Each CLC2 provides alarm and link LEDs that indicate the status of each port These LEDs are located at the bottom of the front panel as illustrated in the figure below Figure 58 Alarm Link LEDs for t...

Page 180: ...his port Yellow ON OFF Yellow Alarm Illuminates Green when a fiber optic cable is plugged into the port and the receive signal is detected by the SFP module Illuminates Yellow when an SFP module is plugged into the port Off indicates that there is no SFP module plugged into the port Green ON Yellow ON OFF Link Checking the LEDs on the RCC s Each RCC is equipped with status LEDs shown in the follow...

Page 181: ...e the troubleshooting information in the table to diagnose the problem Table 77 RCC Run Fail LED States Troubleshooting Description Color None needed Card powered with no errors detected Green Errors were detected during the POSTs It is likely that the errors were logged to the system s command line interface during the boot process Card powered with error s detected Red ASR 5000 Installation Guid...

Page 182: ... from a line card installed behind a packet processing card that has failed to a redundant packet processing card The RCC installed in chassis slot 40 processes traffic for the line cards in chassis slots 17 through 23 and 26 through 32 The RCC installed in chassis slot 41 processes traffic for the line cards in slots 33 through 39 and 42 through 48 See Checking the LEDs on Packet Processing Cards...

Page 183: ...d behind a packet processing card that has failed See Checking the LEDs on Packet Processing Cards on page 144 to determine which packet processing card has failed Completing Initial System Configuration After power is applied to the chassis and the ASR 5000 has successfully booted the command line interface CLI appears on a terminal connected to the Console port of the SPIO The initial configurat...

Page 184: ...ing System Settings and Configuring Management Settings chapters of the System Administration Guide provide detailed procedures for completing the above tasks ASR 5000 Installation Guide 168 Applying Power and Verifying the Installation Completing Initial System Configuration ...

Page 185: ...er includes the following sections Monitoring page 169 Counters and Bulkstats page 173 Summary of Maintenance Tasks page 173 Monitoring This section contains commands used to monitor system performance and the status of tasks managers applications and various other software components Most of the procedure commands are useful for both maintenance and diagnostics There is no limit to the frequency ...

Page 186: ...table show card table all View a listing of all installed application cards in a chassis Determine if all required cards are in active or standby state and not offline Displays include slot numbers card type operational state and attach information show linecard table Display a listing of installed line cards with card type state and attach information Run this command to ensure that all required ...

Page 187: ...nsistent timestamps show logs View both active and inactive system event logs show snmp trap history Check SNMP trap information The trap history displays up to 400 time stamped trap records that are stored in a buffer Through the output you can observe any outstanding alarms on the node and contact the relevant team for troubleshooting or proceed with SGSN troubleshooting guidelines show crash li...

Page 188: ...NOTE If there is an issue with space you can remove alarm and crash information from the system however this practice is not recommended Support and engineering personnel use these records for troubleshooting if a problem should develop You should request assigned support personnel to remove these files after storing the information for possible future use Every 6 Months show hardware card show ha...

Page 189: ...articularly over extended periods of time See Configuring Bulk Statistics section in the System Administration Guide for more information Summary of Maintenance Tasks This section contains a quick reference for when to perform various maintenance operations on the ASR 5000 chassis These operations include but are not limited to Load on the chassis The number of operators regularly accessing it The...

Page 190: ...If you make a config change that you want to be permanent synchronize filesystems between SMCs and save the configuraiton to flash For an expired password re enable the operator as soon as possible If the boot system priority is approaching a low value reset it to a higher priority When you finish troubleshooting with runtime logging remove the logging commands from the config Maintain your SNMP t...

Page 191: ...cards are hot swappable You can install or remove cards from the chassis without powering the chassis down However it is strongly recommended that you add system components during a maintenance window Important This chapter includes the following sections Chassis Slot Numbering and Assignments page 176 Adding Application Cards page 177 Adding Half Height Line Cards page 179 Adding a 10 Gigabit Eth...

Page 192: ...CCs are installed in slots 40 and 41 to prevent damage to the cards or the chassis midplane Important The 10 Gigabit Ethernet Line Card XGLC is a full height line card that takes up the upper and lower slots in the back of the chassis When referring to installed XGLCs use the upper slot number only Slot numbering for other installed half height cards is maintained 17 to 32 and 33 to 48 regardless ...

Page 193: ...wo packet processing cards place them in slots 5 and 12 Important Step 3 Remove the blanking panel if one is installed covering the slot a Use a Phillips 2 screwdriver to loosen the screws at the top and bottom of the blanking panel b Holding the screws on the blanking panel pull the blanking panel away from the chassis to expose the chassis slot Do not leave chassis slots uncovered for extended p...

Page 194: ...lower card mounts for the slot Step 7 Slide the interlock switch on the front panel of the application card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important ASR 5000 Installation Guide 1...

Page 195: ... chassis During installation maintenance and or removal wear a grounding wrist strap to avoid ESD damage to the components Failure to do so could result in damage to sensitive electronic components and potentially void your warranty Caution Step 1 Determine the type of line card you are installing Each line card is identified by the label near the bottom of its front panel Step 2 Determine which c...

Page 196: ... the line card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely Step 8 Use a Phillips 2 screwdriver to tighten the screws at the top and bottom of the line card s front panel to secure the card to the chassis Step 9 Repeat step 1 through step 7 for every other line card that to be installed Step ...

Page 197: ...d QGLC 10 Gigabit Ethernet Line Card XGLC Cabling the Optical ATM Line Card Optical ATM OLC2 Cabling the Channelized Line Card Channelized Line Card Interfaces CLC2 Adding a 10 Gigabit Ethernet Line Card The 10 Gigabit Ethernet Line Card XGLC is a full height line card that occupies two half height slots in the rear of the ASR 5000 chassis It accepts a single Small Form factor Pluggable SFP transc...

Page 198: ...ASR 5000 chassis Installing the XGLC During installation maintenance and or removal wear a grounding wrist strap to avoid ESD damage to the components Failure to do so could result in damage to sensitive electronic components and potentially void your warranty Caution Step 1 Identify the full height chassis slot in which the line card will be installed Step 2 Slide the interlock switch fully downw...

Page 199: ...per and lower card mounts for the slot Step 5 Slide the interlock switch on the front panel of the line card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important ASR 5000 Installation Guide ...

Page 200: ...rd to the chassis Step 7 Repeat step 1 through step 10 for every other line card that to be installed Step 8 Proceed to the appropriate chapter for information on connecting data cables to the line cards ASR 5000 Installation Guide 184 Adding Application and Line Cards to an Existing Installation Installing the XGLC ...

Page 201: ...omponents If your deployment requires the use of PC Cards follow these instructions to safely install and remove the cards The card slot accepts one ATA Type I or Type II PCMCIA card Location of PCMCIA Slot Figure 61 Location of PCMCIA Card on SMC This chapter provides information and instructions for removing and installing the SMC s PCMCIA memory cards It includes the following sections Installi...

Page 202: ...c components and potentially void your warranty Caution Step 1 Identify the slot where you are installing the PC Card Step 2 Use a Phillips 1 screwdriver to remove the two screws securing the PC Card slot cover Step 3 Remove the PC Card slot cover Step 4 Align the PC Card with the slot s upper and lower card guides and slide the card into the slot until it can go no further The face top of the PC ...

Page 203: ...moval wear a grounding wrist strap to avoid ESD damage to the components Failure to do so could result in damage to sensitive electronic components and potentially void your warranty Caution Step 1 Identify the slot from which the PC Card will be removed Step 2 Use a Phillips 1 screwdriver to remove the two screws securing the PC Card slot cover ASR 5000 Installation Guide 187 Removing and Install...

Page 204: ...rd from the slot a Press and release the PC Card ejector button once to release and fully extend it b Firmly press the PC Card ejector button a second time to eject the card ASR 5000 Installation Guide 188 Removing and Installing SMC PC Cards Removing PC Cards ...

Page 205: ...uctions in Installing PC Cards Important Step 6 Align the PC Card slot cover over the open slot Step 7 Use the two screws that you removed in step 2 of this procedure and a Phillips 1 screwdriver to fasten the PC Card slot cover ASR 5000 Installation Guide 189 Removing and Installing SMC PC Cards Removing PC Cards ...

Page 206: ...ASR 5000 Installation Guide 190 Removing and Installing SMC PC Cards Removing PC Cards ...

Page 207: ...sensitive electronic components and potentially void your warranty Caution This chapter includes the following sections Determining When an Air Filter Needs Replacing page 191 Removing the Air Filter page 192 Installing the Air Filter page 194 Determining When an Air Filter Needs Replacing If the air filter is replaced at least every six months as preventive maintenance there should be no need for...

Page 208: ...running at a higher rate of speed Fans running at a higher temperature may be the result of a dirty air filter starFanSpeed The temperature in degrees Celsius as measured on the card A value of 0 indicates that the temperature cannot be read or that the card is not present The maximum measurable temperature is 70 C The safe operating temperature range for the chassis and its sub components is betw...

Page 209: ...rewdriver to remove the fan tray cover Loosen the four screws that secure it in place and pull it away from the chassis Step 2 Raise the plastic tab above the face of the fan tray assembly and gently pull it toward you until the air filter is free from the fan tray assembly ASR 5000 Installation Guide 193 Replacing the Chassis Air Filter Removing the Air Filter ...

Page 210: ...install an air filter Step 1 Verify that the arrows located on the sides of the air filter point upwards The arrows indicate the direction of the airflow into the chassis through the filter Installing the air filter incorrectly may cause over temperature conditions within the chassis Caution Step 2 Slide the air filter into the lower fan tray assembly along the guides located on the lower fan tray...

Page 211: ... air intake is located on the lower fan tray cover Step 5 Replace the fan tray bay cover and tighten each of the four screws to secure it to the chassis The fan tray cover is keyed and can only be installed in one direction Important Step 6 Replace the plastic bezel over the fan tray bay a Align the bezel over the bezel mounts that protrude from the fan tray bay cover b Snap the bezel in place ASR...

Page 212: ...ASR 5000 Installation Guide 196 Replacing the Chassis Air Filter Installing the Air Filter ...

Page 213: ...t includes the following sections Determining that a PFU has Failed page 197 Removing the Failed PFU page 198 Installing the Replacement PFU page 200 What to do with the Failed PFU page 203 Determining that a PFU has Failed The chassis can use one of several mechanisms to indicate a PFU failure The first indicator is when the POWER LED on the PFU is off If the LED is off and a starPowerState SNMP ...

Page 214: ... locking clip move the clip to the right to unlock the circuit breaker s actuator Step 2 Shut down the power source to the failed PFU To avoid the risk of electric shock verify that the power source is completely shut down before proceeding to the next step Vor dem naechsten Schritt Spannungsversorgung abschalten um einen elektrischen Schlag zu vermeiden Step 3 Use a Phillips 2 screwdriver to remo...

Page 215: ...r or socket wrench to remove the nuts and washers that secure the cable to the PFU b Slide the return cable off the terminals Step 6 Use a Phillips 2 screwdriver to loosen the four screws that secure the PFU to the chassis Step 7 Grasp the handle on the PFU and gently pull it toward you The PFU should easily slide out of the chassis ASR 5000 Installation Guide 199 Replacing a Power Filter Unit Rem...

Page 216: ...e circuit breaker actuator on the replacement PFU to the OFF position If the circuit breaker on your PFU is equipped with a locking clip lock the circuit breaker in place Move the breaker s locking clip to the right until the clip s inside tang is recessed in the breaker s actuator opening ASR 5000 Installation Guide 200 Replacing a Power Filter Unit Installing the Replacement PFU ...

Page 217: ...er terminals Each of the four power terminals is shipped with one nut and two washers The 165A PFU has one lock washer and one flat washer To avoid electric shock ensure that the power source is off before attaching power cables to the PFU s installed in the chassis Spannungsversorgung abschalten vor Anschluss der Kabel an die Netzteile um einen elektrischen Schlag zu vermeiden ASR 5000 Installati...

Page 218: ...nuts on the PFU should be torqued to 50 in lb 5 65 N m Step 8 Fasten the lug attached to the power feed cable to the PFU a Insert the lug over the two terminals labeled VDC These are the two bottom terminals on the PFU b Secure the lug to the VDC terminals with the remaining two washers and nuts you removed in step 7 The nuts on the PFU should be torqued to 50 in lb 5 65 N m To avoid the risk of f...

Page 219: ...s still under warranty return it to the vendor for repair If the failed PFU is out of warranty contact Cisco to determine if it can be sent in for repair at an additional cost Disposal of this product should be performed in accordance with all national laws and regulations Important Refer to the support area of http www cisco com for up to date product documentation pertaining to installation conf...

Page 220: ...ASR 5000 Installation Guide 204 Replacing a Power Filter Unit What to do with the Failed PFU ...

Page 221: ...complete failure of either one During installation maintenance and or removal wear a grounding wrist strap to avoid ESD damage to the components Failure to do so could result in damage to sensitive electronic components and potentially void your warranty Caution This chapter includes the following sections Determining Whether a Fan Tray Needs Replacing page 205 Removing an Upper Fan Tray page 207 ...

Page 222: ...aps for Fan Trays Description SNMP Trap One or more fans have failed on the indicated fan controller starFanFailed A fan tray has been removed starFanRemoved The physical location of the fan controller upper or lower starFanLocation The type of failure experienced starFanFailures 0 There are no errors This is the normal operating condition 2 Multiple fans on the fan tray have failed 4 A single fan...

Page 223: ...iver to loosen the four screws securing the fan tray Step 3 Grasp the two bezel mounts on the front of the fan tray and pull toward you The fan tray should easily slide out of the chassis The upper fan tray assembly contains multiple fans that are spinning at a high rate of speed when the system is powered on If system is powered on do not touch moving fans To minimize the risk of personal injury ...

Page 224: ...ge 208 Installing an Upper Fan Tray Follow the instructions below to install an upper fan tray Step 1 Hold the front of the fan tray by its sides and align it with the upper fan tray bay of the chassis Step 2 Slowly slide the fan tray into the chassis along the guides until its face plate is flush against the chassis Step 3 Use a Phillips 1 screwdriver to tighten the four screws on the face plate ...

Page 225: ...a Phillips 1 screwdriver to loosen the four captive screws that hold the fan tray cover EMI shield in place Pull the cover away from the chassis Do NOT use an electric or pneumatic torque driver to loosen these screws Step 3 Pull the fan tray toward you with the handle cut out on the front of the fan tray assembly The fan tray assembly should easily slide out of the chassis ASR 5000 Installation G...

Page 226: ... Die obere Lüfter Schublade enthaelt mehrere Lüfter Verletzungsgefahr bei Beruehrung der Lüfter Hohe Umdrehungszahl der Lüfter unter Stromanschluss Vorsicht nicht beruehren Um persoenliche Verletzungen und Geraeteschaden zu verhueten bitte Anleitungen beachten 1 Schublade ca 5cm herausziehen 2 30 Sekunden warten bis die Luefter zum stehen kommen 3 Schublade erst jetzt komplett herausziehen Step 4 ...

Page 227: ...s Step 2 Slowly slide the fan tray into the chassis along the guides until it is seated firmly in the chassis and can go no further Step 3 Verify that the particulate filter is securely in place Its front should be flush with the front of the fan tray assembly and its tab should be lowered to keep it in place ASR 5000 Installation Guide 211 Replacing Upper or Lower Fan Tray Installing a Lower Fan ...

Page 228: ...fan tray is still under warranty return it to the vendor for repair If the failed fan tray is out of warranty contact Cisco to determine if it can be sent in for repair at an additional cost Disposal of this product should be performed in accordance with all national laws and regulations Important Refer to the support area of http www cisco com for up to date product documentation pertaining to in...

Page 229: ...ry Card on SMCs page 219 What to do with the Failed Application Card page 221 Determining Whether an Application Card has Failed The system has several ways to indicate an application card failure The first indicator is that the Status LED on the System Management Card SMC turns red to indicate the failure of a chassis component Another indicator is the Run Fail LED on an application card is red o...

Page 230: ...tion appears to be erroneous such as the operational state or an LED state check for any of the SNMP alarms listed in Using SNMP Traps on page 214 Using SNMP Traps The system supports SNMP traps that are triggered when conditions indicate the need to replace an application card The system provides the traps listed in the table below Table 83 SNMP Traps for Application Cards Description SNMP Trap A...

Page 231: ...itchoverStart An SMC Switchover has completed successfully The starSlotNum varbind identifies the new primary SMC starCardSMCSwitchoverComplete An SMC switchover operation has failed The first varbind identifies the SMC whose tasks are being switched from the second varbind identifies the SMC to which the tasks are being switched starCardSMCSwitchoverFailed If any of the above traps have been gene...

Page 232: ...tep 4 Holding the card by its ejector levers gently slide the card out of the chassis by pulling the card toward you Do not leave chassis slots uncovered for extended periods of time This reduces airflow through the chassis and could cause it to overheat Make sure a card or a blanking panel is installed in every chassis slot at all times Caution Step 5 Proceed to Installing the Application Card on...

Page 233: ... Holding the card by its ejector levers align the card with the upper and lower card guides of the appropriate chassis slot and gently slide the card into the slot until the levers touch the chassis frame Take extra caution when installing packet processing cards These cards contain heat sinks that could become loose or damaged if they come into contact with an adjacent card while the packet proce...

Page 234: ...the chassis upper and lower card mounts for the slot Step 4 Slide the interlock switch on the front panel of the application card upward to lock the ejector tab in place The flange on the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important ASR 500...

Page 235: ...he location of the CompactFlash memory card on the SMC Figure 62 Location of CompactFlash Card In the event of an SMC hardware failure you must remove the CompactFlash from the failed card and install it on the replacement SMC This ensures that the proper software image configuration files and license keys are loaded as the system boots To reduce the risk of damage handle the CompactFlash memory c...

Page 236: ...ion in the replacement SMC Step 1 On the failed SMC remove the card retainer clip that secures the CompactFlash module in the socket by pulling the ends of the card retainer clips out and away from the socket Step 2 Gently pull the module out of the socket ASR 5000 Installation Guide 220 Replacing Application Cards Replacing the CompactFlash on an SMC ...

Page 237: ... clip to secure the CompactFlash module in place Step 6 Proceed to Installing the Application Card on page 217 for instructions on installing the replacement SMC What to do with the Failed Application Card If the failed application card is still under warranty return it to the vendor for repair ASR 5000 Installation Guide 221 Replacing Application Cards What to do with the Failed Application Card ...

Page 238: ...ea of http www cisco com for up to date product documentation pertaining to installation configuration and maintenance A valid username and password is required to use this site Please contact your local sales or service representative for additional information For additional information on the RMA process see the RMA Shipping Procedures appendix Important ASR 5000 Installation Guide 222 Replacin...

Page 239: ... Line Card page 226 What to do with the Failed Line Card page 228 Determining Whether a Line Card has Failed There are several ways the chassis indicates a line card failure The first indicator is that the Status LED on the System Management Card SMC turns red to indicate the failure of a chassis component Another is that the Run Fail LED turns red or turns off on a line card that has a problem If...

Page 240: ...Usable Yes Single Point of Failure No Attachment 8 Switch Management Card Temperature 32 C limit 85 C Voltage Good Card LEDs Run Fail Green Active Green Standby Off If any of the above information appears to be erroneous such as the operational state or an LED state check for any of the SNMP alarms listed in Using SNMP Traps on page 224 Using SNMP Traps The system supports SNMP traps that are trig...

Page 241: ...o loosen the screws at the top and bottom of the line card s front panel Step 3 Slide the interlock switch on the front panel of the line card downward To avoid damaging the card s interlock switch ensure that it is completely down before proceeding To minimize the risk of data loss ensure that all LEDs on the line card are Off extinguished prior to removing the card from the chassis Caution Step ...

Page 242: ...aution Installing the Line Card Step 1 Slide the interlock switch on the card fully downward Flip the ejector levers outward and away from the card s faceplate Step 2 Hold the card by its ejector levers and align it with the upper and lower card guides of the chassis slot Gently slide the card into the slot until the levers touch the chassis frame ASR 5000 Installation Guide 226 Replacing Line Car...

Page 243: ...n the left side of the interlock switch prevents movement of the ejector tab when raised completely You must slide the interlock switch upward before securing the card s top screw to the mounting rail Important Step 5 Use a Phillips 2 screwdriver to tighten the screws at the top and bottom of the line card s front panel to secure the card to the chassis Step 6 Refer to the destination label on eac...

Page 244: ...t to the vendor for repair If the failed line card is out of warranty contact Cisco to determine if you can send it in for repair at an additional cost Disposal of this product should be performed in accordance with all national laws and regulations Important Refer to the support area of http www cisco com for up to date product documentation pertaining to installation configuration and maintenanc...

Page 245: ...ent cabinet or telecommunications rack The table below lists the dimensions for the chassis and each component that can be placed within the chassis Table 85 Physical Dimensions ASR 5000 Chassis and Components Depth Width Height Component 24 0 in 60 96 cm 17 5 in 44 45 cm 24 50 in 62 23 cm Chassis 14 10 in 35 81cm 1 01in 2 56 cm 17 05 in 46 31 cm Application Card 5 24 in 13 31cm 1 01in 2 56 cm 8 5...

Page 246: ...ped chassis shipping container and packing materials 307 lbs 139 25 kg Fully loaded as shipped chassis with all slots filled with cards Packet Processing Cards 11 50 lbs 5 22 kg Packet Services Card 2 PSC2 11 0 lbs 4 95 kg Packet Service Card 3 PSC3 1 25 lbs 0 57 kg Switch Process I O Card SPIO 10 00 lbs 4 54 kg System Management Card SMC Line Cards 1 25 lbs 0 57 kg Channelized Line Card 2 CLC2 1 ...

Page 247: ...ue Characteristic Maximum range 40VDC to 60VDC Nominal range 48VDC to 60 VDC Input Voltage 165A 48 VDC TUV Rated Peak Current Load 5760W Maximum Peak Power Load 800W Chassis Maximum Power Load SPIO 15W FLC2 13 5W GLC2 10 5W QGLC 15W XGLC 25W OLC2 23W CLC2 23W RCC 20W Line Card rear installed Maximum Power Load SMC 130W PSC2 325W PSC3 330W Application Card front installed Maximum Power Load PFU 160...

Page 248: ...mounting brackets supplied with the chassis Additional hardware not supplied such as extension brackets may be used to install the chassis in a standard 23 inch 584 2 mm cabinet or rack Both front and mid mount installations are possible depending on the position of the mounting brackets on the chassis You can mount a maximum of three ASR 5000 chassis in a 2 or 4 post equipment rack or telco cabin...

Page 249: ...ent racks and cabinets as well as supplier recommended fasteners The following figure depicts how three chassis can be mounted in a 42 RU equipment rack Figure 63 Three ASR 5000 Chassis in a 42 RU Rack ASR 5000 Installation Guide 233 Technical Specifications Mounting Requirements ...

Page 250: ...Pin optional 1 RJ 45 Ethernet 8 10 100 Ethernet FLC2 3 SFP SX 1 Gigabit Ethernet GLC2 SFP LX SFP T copper RJ 45 4 SFP SX 4 Gigabit Ethernet QGLC SFP LX SFP T copper RJ 45 5 10GBase SR SFP 1 10 Gigabit Ethernet XGLC 10GBase LR SFP Single mode Fiber LC duplex 1 ATM POS OC 3 SM IR 1 OLC2 Multi mode Fiber LC duplex ATM POS OC 3 Multi Mode Single mode Fiber LC duplex 1 Channelized STM 1 OC 3 SM IR 1 CL...

Page 251: ... Port The Console port is an RJ 45 RS 232 interface used to access the command line interface The interface communicates at a baud rate of 9600 to 115 200 bps 115 2 Kbps The default is 115 200 bps Table 89 SPIO Console RJ 45 Pinout Signal Type Signal Description Pin Input Clear to Send CTS 1 Input Data set Ready DSR 2 Input Receive Data RX 3 N A Signal Ground SGND 4 Output Ready to Send RTS 5 Outp...

Page 252: ...ata RxD SGND 5 4 N A Signal Ground SGND CTS 8 5 Output Ready to Send RTS RxD 2 6 Output Transmit Data TxD DCD 1 7 Input Data Carrier Detect DCD DSR 6 8 Output Data Terminal Ready DTR To construct a RJ 45 to DB 25 cable for modem connectivity refer to the table that follows Table 91 RJ 45 to DB 25 Cable Signal DB 25 Pin RJ 45 Pin Signal Type Signal Description CTS 5 1 Input Clear to Send CTS DSR 6 ...

Page 253: ...Bm Max TX 9 5 dBm Min TX 0 dBm saturation average power Max RX 20 typical 17 max dBm sensitivity average power Min RX 10 100 1000 Mbps RJ 45 Interface The two RJ 45 interfaces are auto sensing 10 100 1000 Ethernet 10Base T 100Base TX 1000Base T that require unshielded twisted pair UTP copper cable Table 93 SPIO RJ 45 Ethernet Interface Pinouts 1000Base Tx 1Gbps Cat5 100Base Tx 100Mbps Cat5 10Base ...

Page 254: ...ally open 3 Minor Alarm Normally closed 4 Minor Alarm Common 5 Minor Alarm Normally open 6 Critical Alarm Normally closed 7 Critical Alarm Common 8 Critical Alarm Normally open 9 Not used 10 The 8 foot 2 4 meter CO alarm cable shipped with the chassis supports redundant SPIO card installations This Y cable has two Molex connectors on one end that are keyed to fit into the CO Alarm interfaces in on...

Page 255: ... Alarm Normally closed 1 Black 1 Major Alarm Common 2 Orange 2 Major Alarm Normally open 3 Red 3 Minor Alarm Normally closed 4 Brown 4 Minor Alarm Common 5 Yellow 5 Minor Alarm Normally open 6 Green 6 Critical Alarm Normally closed 7 Blue 7 Critical Alarm Common 8 Violet 8 Critical Alarm Normally open 9 Gray 9 Not applicable Not equipped Not wired 10 ASR 5000 Installation Guide 239 Technical Speci...

Page 256: ...lays can each control up to two external alarm indicators In this example the CO alarm interface is connected to a CO Alarm Panel where green LEDs are wired to indicate normal operation and red LEDs are wired to indicate an alarm condition Figure 66 CO Alarm Interface Schematic With all relays de energized normally closed the green LED is illuminated If an alarm relay is energized the NO normally ...

Page 257: ...he BITS BNC timing interface Figure 67 SPIO E1 BITS BNC Pinout BITS T1 3 Pin Interface The 3 pin version of the SPIO employs a wire wrap connector that accepts a T1 DS1 BITS data signal all ones from which the SPIO derives a 1544 kHz clock The following figure shows the BITS 3 wire timing interface wire wrap pin out Figure 68 SPIO T1 BITS Wire Wrap Pinout Fast Ethernet Line Card FLC2 Interfaces Ea...

Page 258: ... connectors The Quad Gigabit Ethernet Card QGLC has four pairs Table 97 100Base SX Fiber Transmit and Receive Levels Level Signal 0 dBm Max TX 9 5 dBm Min TX 0 dBm saturation average power Max RX 20 typical 17 max dBm sensitivity average power Min RX 1000Base LX Interface The 1000Base LX fiber SFP interface on the Ethernet 1000 LX line card has one pair of host connectors The QGLC has four pairs A...

Page 259: ...lded twisted pair UTP copper CAT 5 cable with a bit error rate BER less than 10e 10 Pinouts for the RJ 45 Ethernet ports are shown in the table below Table 99 1000Base T RJ 45 Ethernet Copper Pinouts 1000Base Tx 1Gbps Cat5 Pin BI DA 1 BI DA 2 BI DB 3 BI DC 4 BI DC 5 BI DB 6 BI DD 7 BI DD 8 RX Receive Data TX Transmit Data BI BI directional data DA DB DC DD Data Pair A B C and D ASR 5000 Installati...

Page 260: ...LR fiber SFP interface on the XGLC has one pair of host connectors Table 101 10GBase LR Fiber Transmit and Receive Levels Level Signal 0 5 dBm Max TX 8 2 dBm Min TX 0 5 dBm saturation average power Max RX 12 6 max dBm sensitivity average power Min RX Fiber ATM POS OC 3 OLC2 Multi Mode Interface Fiber ATM POS OC 3 SM IR 1 Interface The fiber optic SFP interface on OLC2 Optical ATM Line Cards with t...

Page 261: ...Bm Max TX 19 dBm Min TX 12 dBm saturation average power Max RX 30 max dBm sensitivity average power Min RX Channelized Line Cards Channelized Line Card CLC2 with Single Mode Interface The optical SFP interface on the 4 port CLC2 with the single mode interface has four pairs of connectors that accept SFP transceivers Table 104 Single Mode Fiber Transmit and Receive Levels Level Signal 8 dBm Max TX ...

Page 262: ...face has four pairs of connectors that receive SFP transceivers Table 105 Multi Mode Fiber Transmit and Receive Levels 0 Level Signal 14 dBm Max TX 19 dBm Min TX 12 dBm saturation average power Max RX 30 max dBm sensitivity average power Min RX ASR 5000 Installation Guide 246 Technical Specifications Channelized Line Cards ...

Page 263: ...itions This device must not cause harmful interference This device must withstand any interference received including interference that may cause undesired operation These limits provide reasonable protection against harmful interference when this equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in ...

Page 264: ...Equipment 3rd Edition European Union EN 60950 CE Mark Electrical Certifications The ASR 5000 complies with all electrical certifications listed below Telcordia GR 1089 Core Network Equipment Building System NEBS Requirements Electromagnetic Compatibility and Electrical Safety Criteria for Network Telecommunication Equipment FCC Part 15 B Class A Requirements for Non residential Equipment ETSI EN 3...

Page 265: ...evices to operate as intended in proximity to other electronic devices or in the presence of electromagnetic fields Unintentional radio frequency emissions from an electronic device and immunity of the device to radio frequency interference from other electromagnetic sources are included within electromagnetic compatibility Japan VCCI A The ASR 5000 has been registered for compliance with the Volu...

Page 266: ...ASR 5000 Installation Guide 250 Safety Electrical and EMC Certifications Korean EMC ...

Page 267: ...se the following information to plan your network installation for the ASR 5000 platform Table 106 Temperature Humidity and Altitude Recommendations Temperature 0 degrees C to 55 degrees C 32 degrees F to 130 degrees F Operating 40 degrees C to 70 degrees C 40 degrees F to 158 degrees F Storage Humidity 20 to 80 percent non condensing Operating 10 to 95 percent non condensing Storage Altitude 197 ...

Page 268: ...7 79 Acoustic Noise GR 63 Criterion 128 ESTI 300 019 Environmental conditions and environmental tests for telecommunications equipment Chassis Air Flow Airflow within the ASR 5000 is designed per Telcordia recommendations to ensure the proper vertical convection cooling of the system As shown in the figure below the lower fan tray pulls ambient air into the chassis from the front and side intake v...

Page 269: ...on When planning chassis installation ensure that equipment rack or cabinet hardware does not hinder air flow at any of the intake or exhaust vents Additionally ensure that the rack cabinet hardware as well as the ambient environment allow the system to function within the operating limits specified in this chapter Caution ASR 5000 Installation Guide 253 Environmental Specifications Chassis Air Fl...

Page 270: ...ASR 5000 Installation Guide 254 Environmental Specifications Chassis Air Flow ...

Page 271: ...cards that are capable of running the service in this StarOS release Packet processing cards included in this matrix are PSCA Packet Service Card Type A interchangeable with PSC PSC2 Packet Service Card Type 2 PSC3 Packet Service Card Type 3 PPC Packet Processing Card The products embedded services included in this matrix are CDMA PDSN HA Packet Data Serving Node Home Agent HSGW HRPD Serving Gatew...

Page 272: ...licy Control Function IPSG IP Services Gateway MGW Media Gateway OGW Offload Gateway SGSN Serving GPRS Support Node Table 107 Packet Processing Card Product Support Matrix PPC PSC3 PSC2 PSCA Embedded Service CDMA No Yes Yes Yes PDSN HA No Not Qualified Yes Yes HSGW No Not Qualified Yes No PMIPv6 Femtocell NA Not Qualified NA No CDMA No Not Qualified Yes No LTE No Not Qualified Yes No UMTS LTE No Y...

Page 273: ...operate with the service in this StarOS release Line cards included in this matrix are SPIO Switch Processor I O RCC Redundancy Crossbar Card FLC2 Fast Ethernet Line Card GLC2 Gigabit Ethernet Line Card QGLC Quad Gigabit Ethernet Line Card XGLC 10 Gigabit Ethernet Line Card CLC2 Channelized Line Card Frame Relay over SDH SONET STM 1 OC 3 OLC2 Optical Line Card ATM over SDH SONET signaling IPoA PVC...

Page 274: ...o No Yes Yes Yes Yes Yes Yes SGW Security Gateway No No Yes Yes Yes Yes Yes Yes ePDG No No Yes Yes Yes Yes Yes Yes PDIF No No Yes Yes Yes Yes Yes Yes TTG PDG Other No No Yes Yes Yes Yes Yes Yes GGSN No No Yes Yes Yes Yes Yes Yes IMS MMD No No Yes Yes Yes Yes Yes Yes IPCF No No Yes Yes Yes Yes Yes Yes IPSG No No Yes Yes Yes Yes Yes Yes MGW No No Yes Yes Yes Yes Yes Yes OGW Yes Yes Yes Yes Yes Yes Y...

Page 275: ...such as the XGLC you must prepare a full height slot to receive it Full height line cards occupy two half height slots an upper chassis slot and the lower chassis slot directly beneath it For example if a PSC2 is installed in slot 1 its corresponding XGLC would be installed in slots 17 and 33 When entering the slot location of a full height line card in a CLI command use the upper slot number only...

Page 276: ...tep 3 Repeat step 2 to remove the half height blanking panel covering the chassis slot directly below the slot exposed in the previous step On a powered up chassis do not leave chassis slots uncovered for extended periods of time This reduces airflow through the chassis which could cause it to overheat Install a card or a blanking panel s in every chassis slot Caution Remove the Half Height Card G...

Page 277: ...t strips to allow access to the screws beneath Save the gasket strips Step 2 Using a Phillips 1 screwdriver loosen the two screws that secure the half height card guide ejector rail cap Save the screws for later use Step 3 Remove the half height card guide ejector rail cap ASR 5000 Installation Guide 261 Preparing a Full Height Line Card Slot Remove the Half Height Card Guide ...

Page 278: ...provided with the full height line card to loosen the screw that secures the half height card guide to the chassis mid plane ASR 5000 Installation Guide 262 Preparing a Full Height Line Card Slot Remove the Half Height Card Guide ...

Page 279: ...card guide out of the chassis You may need to slightly angle the guide when you slide it out of the chassis to unlatch it Important ASR 5000 Installation Guide 263 Preparing a Full Height Line Card Slot Remove the Half Height Card Guide ...

Page 280: ...ASR 5000 Installation Guide 264 Preparing a Full Height Line Card Slot Remove the Half Height Card Guide ...

Page 281: ...ents must be properly packaged to prevent damage in transit Items should never be shipped without packaging foam bubble wrap and a static bag Crushed or damaged boxes pallets should never be used for returning items Important The following general guidelines apply when packaging components It is best to use the original Cisco box and packaging in which your equipment was sent and received You can ...

Page 282: ...ough to handle the weight and size of the items within it Items should never be returned loosely packed and unprotected from ESD Important Sealing the Shipment The box or shipping container must be securely sealed using appropriately reinforced packaging tape Do not use masking or transparent light duty tape to secure or seal packaging Chassis or other large units must be covered and securely stra...

Page 283: ...Application Cards Application Card Types The packing instructions in this section apply to the following full height SMC and packet processing cards ASR5K SMC K9 System Management Card SMC ASR5K PSC 64G K9 Packet Services Card 3 PSC3 ASR5K PSC 32G K9 Packet Services Card 2 PSC2 ASR5K PSC 16G K9 Packet Services Card Type A PSCA ASR5K PPC K9 Packet Processing Card 3 PPC Packaging an Application Card...

Page 284: ... an SMC a foam block must be removed from the bottom foam near the connector cut outs Step 3 Place the card in the carton as shown in the photos ASR 5000 Installation Guide 268 RMA Shipping Procedures Application Cards ...

Page 285: ... packing instructions in this section apply to the following half height card types ASR5K C4OC3 MM K9 Channelized Line Card 2 CLC2 MM SFP ASR5K C4OC3 SM K9 Channelized Line Card 2 CLC2 SM SFP ASR5K 01100E K9 Fast Ethernet Line Card FELC ASR5K 08100E K9 Fast Ethernet Line Card 2 FLC2 ASR5K 4OC3C MM K9 Optical Line Card 2 OLC2 MM SFP ASR5K 4OC3C SM K9 Optical Line Card 2 OLC2 SM SFP ASR5K 041GE SX K...

Page 286: ...11G2 SX K9 Gigabit Ethernet 1000 Line Card GLC2 SX MM SFP ASR5K 011G2 LX K9 Gigabit Ethernet 1000 Line Card GLC2 LX SM SFP ASR5K 011G2 T K9 Gigabit Ethernet 1000 Line Card GLC2 copper SFP ASR5K RCC K9 Redundancy Crossbar Card RCC ASR5K SPIO BNC K9 Switch Processor I O BNC BITS ASR5K SPIO 3PN K9 Switch Processor I O 3 Pin BITS ASR5K SPS3 BNC K9 Switch Processor I O BNC BITS with Stratum 3 module AS...

Page 287: ...the bottom piece of foam as shown in the photos If packing an RCC or SPIO a foam block must be removed from the bottom foam near the connector cut outs ASR 5000 Installation Guide 271 RMA Shipping Procedures Line Cards except XGLC ...

Page 288: ... of foam and place the cable assembly in the cutout Step 5 Close the carton and seal it with packaging tape See Sealing the Shipment for additional information Step 6 Place the shipping label on the outside of the carton See Labeling the Shipment for additional information ASR 5000 Installation Guide 272 RMA Shipping Procedures Line Cards except XGLC ...

Page 289: ...a Full Height XGLC The packaging sequence is as follows Step 1 Place the card inside the ESD bag fold over and seal the bag with an ESD Label or tape as shown in the photos Step 2 The XGLC shipping carton includes a bottom foam piece and two top foam pieces Insert the XGLC in the bottom foam piece and place the two top pieces in the slots at either ends of the card as shown in the photos ASR 5000 ...

Page 290: ...ape See Sealing the Shipment for additional information Step 4 Place the shipping label on the outside of the carton See Labeling the Shipment for additional information ASR 5000 Installation Guide 274 RMA Shipping Procedures 10 Gigabit Ethernet Card XGL ...

Page 291: ...er features incorporated within the system Cisco recommends that the following minimum spare parts levels for any ASR 5000 deployment Table 109 Recommended FRU Parts Sparing Quantities For every n number of deployed components Minimum number of spares Component Name 20 1 ASR 5000 Chassis with Midplane 30 1 Power Filter Unit 165A 10 1 System Management Card SMC 12 1 Packet Services Card PSC2 or PSC...

Page 292: ...ased on industry leading redundancy and failover features incorporated within the system Cisco recommends that the following minimum spare parts levels for any ASR 5000 deployment Table 110 Recommended FRU Parts Sparing Quantities For every n number of deployed components Minimum number of spares Component Name 20 1 ASR 5000 Chassis with Midplane 30 1 Power Filter Unit 165A 10 1 System Management ...

Page 293: ...umber of deployed components Minimum number of spares Component Name 5 1 Lower Fan Tray Unit 1 1 Particulate Air Filter ASR 5000 Installation Guide 277 Spare Component Recommendations Spare Component Recommendations ...

Page 294: ...ASR 5000 Installation Guide 278 Spare Component Recommendations Spare Component Recommendations ...

Reviews: