Table 14: PFU POWER LED States
Troubleshooting
Description
Color
None needed.
PFU powered with no errors
detected
Green
Verify that the power switch is in the ON position.
PFU is not receiving power
None
Verify that the RTN and -VDC lugs are attached properly.
Verify that the ground lug is attached properly. Verify that the power
source is on and is supplying the correct voltage and sufficient current.
Check the cables from the power source to the rack for continuity.
If a power distribution panel (PDP) is installed between the power
distribution frame (PDF) and the chassis, verify that the circuit breakers
are set to ON.
If a PDP is installed between the PDF and the chassis, check the cables
from the PDP to the chassis for continuity.
If all of the above suggestions have been verified, then it is likely that
the PFU is not functional. Please contact your service representative.
Checking the LEDs on the SMC
Each SMC is equipped with the following LEDs as shown in the accompanying figure:
•
Run/Fail
•
Active
•
Standby
•
Status
•
Service
ASR 5000 System Administration Guide, StarOS Release 21.1
199
Troubleshooting
Checking the LEDs on the SMC