Chapter 1 Overview
Hardware Features
Along with robust and reliable Cisco Outdoor WI-FI wireless mesh, it also creates parallel Industrial
Wireless Automation Network to support field sensors and actuators running on ISA100.11a protocol.
The backbone router manages and aggregates Industrial Wireless Data and passes it over to the Cisco
Wireless Mesh backbone. Cisco Wireless Mesh carries Industrial Wireless Traffic with highest priority
(or QoS) with minimal latency and highest reliability and routes it to the Wireless Device Manager,
which is part of the Honeywell One Wireless Infrastructure Solution.
Refer to Cisco Documentation for installation, configuration, best practices and troubleshooting guides
on
www.cisco.com
.
Refer to Honeywell One Wireless Plant Solution documentation on
www.honeywell.com
for further
details.
Honeywell Backbone Router Activation Process
The following steps describe conceptual process and flow only. Refer to Honeywell’s detailed
documentation for configuration information.
Step 1
This process assumes that you have Honeywell One wireless setup installed. It includes, but is not
limited to, the Honeywell WDM and Honeywell or other compatible ISA100 sensors. The Honeywell
WDM should be configured according to Honeywell’s documentation.
Step 2
Once you have the WDM and other infrastructure configured according to Honeywell documentation,
activate the provisioning device provided by Honeywell in the WDM by connecting to the WDM USB
port according Honeywell documentation.
Step 3
Create keys on the WDM and download/transfer them on a handheld device.
Step 4
Launch provisioning application on handheld device. Point this handheld device towards the Infrared
Sensor on the 15552SA/1552SD and press activate button on the Honeywell Provisioning application.
Handheld device will transfer / communicate keys to Honeywell BBR and get status if activated
successfully.
Step 5
Same process needs to be applied for sensors to be activated and included in Industrial Wireless Sensor
Network.
Step 6
All these devices can be Configured and monitored in Honeywell WDM once they are part of wireless
network.