Chapter 1      Overview

Hardware Features

Along with robust and reliable Cisco Outdoor WI-FI wireless mesh, it also creates parallel Industrial 
Wireless Automation Network to support field sensors and actuators running on ISA100.11a protocol. 
The backbone router manages and aggregates Industrial Wireless Data and passes it over to the Cisco 
Wireless Mesh backbone. Cisco Wireless Mesh carries Industrial Wireless Traffic with highest priority 
(or QoS) with minimal latency and highest reliability and routes it to the Wireless Device Manager, 
which is part of the Honeywell One Wireless Infrastructure Solution.

Refer to Cisco Documentation for installation, configuration, best practices and troubleshooting guides 
on 

www.cisco.com

.

Refer to Honeywell One Wireless Plant Solution documentation on 

www.honeywell.com

 for further 

details.

Honeywell Backbone Router Activation Process

The following steps describe conceptual process and flow only. Refer to Honeywell’s detailed 
documentation for configuration information.

Step 1

This process assumes that you have Honeywell One wireless setup installed. It includes, but is not 
limited to, the Honeywell WDM and Honeywell or other compatible ISA100 sensors. The Honeywell 
WDM should be configured according to Honeywell’s documentation.

Step 2

Once you have the WDM and other infrastructure configured according to Honeywell documentation, 
activate the provisioning device provided by Honeywell in the WDM by connecting to the WDM USB 
port according Honeywell documentation.

Step 3

Create keys on the WDM and download/transfer them on a handheld device.

Step 4

Launch provisioning application on handheld device. Point this handheld device towards the Infrared 
Sensor on the 15552SA/1552SD and press activate button on the Honeywell Provisioning application. 
Handheld device will transfer / communicate keys to Honeywell BBR and get status if activated 
successfully.

Step 5

Same process needs to be applied for sensors to be activated and included in Industrial Wireless Sensor 
Network.

Step 6

All these devices can be Configured and monitored in Honeywell WDM once they are part of wireless 
network.

Summary of Contents for AIR-CAP1552H-x-K9

Page 1: ...s and offers enhanced backhaul performance The 1552 access point can also be configured with an integrated ISA 100 or WirelessHART Gateway The access point is a standalone unit that can be pole mounted The access point can also operate as a relay node for other access points not directly connected to a wired network Intelligent wireless routing is provided by the patented Adaptive Wireless Path Pr...

Page 2: ...es for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Models Hardware Models The model numbers or part numbers and configuration for the Cisco Aironet 1552 Outdoor Mesh Access Points for Hazardous Locations are described in Table 1 1 A detailed list of components supported by each 1552 access point model is shown in Table 1 2 For a detailed description of the declarations of co...

Page 3: ...0900aecd80537b6a html AIR CAP1552SA x K9 and AIR CAP1552SD x K9 Two radio 2 4 GHz and 5 GHz modular version This model supports three 3 external dual band omnidirectional antennas The antennas can be ordered with the model This model also supports two ISA100 radios with 2 additional external omnidirectional antennas for connections to 802 15 4 sensor network transceivers Countries regulatory domai...

Page 4: ...epresent the domain For example in AIR CAP1552H x K9 the x represents a regulatory domain for a specific country For specific regulatory domains supported by each 1552 access point model refer to the Wireless LAN Compliance Status at http www cisco com en US prod collateral wireless ps5679 ps5861 product_data_sheet0900aecd805 37b6a html To locate the 1552 access point models click on 802 11abgn Me...

Page 5: ...al antenna Type N connectors Note The illustrations in this document show all available connections for the access point Unused connections are capped with a connector plug to ensure the watertight integrity of the access point Liquid tight adapters are provided for connector openings which can be installed before or after deploying the access point Figure 1 2 Access Point Model AIR CAP1552H x K9 ...

Page 6: ...etail php item 790021 1 6 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Figure 1 3 Access Point Model AIR CAP1552SA SD x K9 Bottom Connectors Figure 1 4 Console Port for Access Point Model AIR CAP1552H x K9 and AIR CAP1552SA SD x K9 4 1 3 2 5 6 8 7 331096 1 Antenna port 4 ISA100 11a 5 Not used 2 IR window 6 PoE out port 3 Antenna port 6 I...

Page 7: ... gerne weiter Den aktuellen Preis und Lagerstand finden Sie online auf http www diskontcomputer com detail php item 790021 1 7 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Figure 1 5 Access Point DC Power Connector and Ground Lug All Models 1 DC power port 3 Bracket mounting hole 2 Bracket mounting hole 4 Ground lug location connection f...

Page 8: ...ne auf http www diskontcomputer com detail php item 790021 1 8 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Figure 1 6 shows the antenna port locations for model AIR CAP1552H x K9 Figure 1 6 External Antenna Port Locations for Access Point Model AIR CAP1552H x K9 1 Not used 4 Antenna port 6 Type N connector 2 4 5GHz Tx Rx 2 Not used 5 An...

Page 9: ...em 790021 1 9 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Figure 1 7 shows the antenna port locations for model AIR CAP1552SA SD x K9 Figure 1 7 External Antenna Port Locations for Access Point Model AIR CAP1552SA SD x K9 1 Antenna port 1 Type N connector WiFi 2 4 5GHz TX RX 4 Antenna port 6 Type N connector ISA100 2 4GHz Tx Rx 2 Antenn...

Page 10: ...552WU x K9 Figure 1 8 External Antenna Port Locations for Access Point Model AIR CAP1552WU x K9 1 Antenna port 1 Type N connector Single Band 5 GHz Omnidirectional WiFi Antenna TX RX 4 Antenna port 4 optional Type N connector Single Band 2 4 GHz Omnidirectional WiFi Antenna TX RX 2 Antenna port 2 Type N connector Single Band 5 GHz Omnidirectional WiFi Antenna RX 5 Antenna port 5 optional Type N co...

Page 11: ... total maximum output power for the upper ISM band is 28 dBm Output power is configurable for 5 power levels in 3 dB steps The three receivers enables maximum ratio combining MRC Antenna Configurations The 1552SA 1552SD 1552H and 1552WU models must always be operated with all the external antennas attached Figure 1 6 Figure 1 7 and Figure 1 8show the antenna port locations Table 1 3 Cisco Aironet ...

Page 12: ...gerstand finden Sie online auf http www diskontcomputer com detail php item 790021 1 12 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Figure 1 9 Cisco Aironet Dual Band Omnidirectional Antenna Installed on Model AIR CAP1552H x K9 1 Antenna connected to antenna port 1 Type N connector WiFi TX RX Antenna connected to antenna port 2 Type N c...

Page 13: ... Band Omnidirectional Antenna and Cisco Aironet 2 4 GHz Omnidirectional Antenna Installed on Model AIR CAP1552SA SD x K9 Safety Precautions Warning Do not locate the antenna near overhead power lines or other electric light or power circuits or where it can come into contact with such circuits When installing the antenna take extreme care not to come into contact with such circuits as they may cau...

Page 14: ... the operation to issue instructions and watch for signs of trouble 5 When installing your antenna follow these guidelines Do not use a metal ladder Do not work on a wet or windy day Do dress properly wear shoes with rubber soles and heels rubber gloves and a long sleeved shirt or jacket 6 If the assembly starts to drop move away from it and let it fall Because the antenna mast cable and metal guy...

Page 15: ...e access point should be provided with ground fault protection GFCI as required by Article 210 of the National Electrical Code NEC 1552H and 1552SA not for 1552SD and 1552WU Ethernet PoE Ports Note The 1552SA 1552SD and 1552WU access points do not support the PoE In port The 1552 hazardous location access points support an Ethernet uplink port and a downlink port POE Out The 1552H access point als...

Page 16: ...ed over a dual strand fiber cable which is connected to the access point using these SFP modules 100BASE BX10 U fiber Rugged small form factor pluggable SFP module 1000BASE LX single mode Rugged SFP module 1000Base SX multimode Rugged SFP module Note SFP modules are not hot swappable The access point has one fiber connection located on the bottom of the unit shown on Figure 1 2 Client data is pass...

Page 17: ...point must be configured as a RAP A RAP is a parent node to any bridging or mesh network A controller can support one or more RAPs each one parenting the same or different wireless networks There can be more than one RAP for the same mesh network for redundancy RAPs and MAPs can support wireless clients on the 2 4 GHz and 5 GHz band Client access on 5 GHz is called universal client access When the...

Page 18: ... this capability is turned off for all access points Wireless client access is supported however if bridging between tall buildings the 2 4 GHz wireless coverage area may be limited and possibly not suitable for direct wireless client access Figure 1 12 Access Point Point to Point Bridging Example Point to Multipoint Bridging The access points can be used as a RAP to connect multiple remote MAPs w...

Page 19: ... In the mesh network the links between the access points are referred to as the backhaul links Intelligent wireless routing is provided by the Adaptive Wireless Path protocol AWPP This enables each MAP to identify its neighbors and intelligently choose the optimal path to the RAP with the wired network connection by calculating the cost of each path in terms of signal strength and the number of ho...

Page 20: ...neywell One Wireless Plant Solution documentation on www honeywell com for further details Honeywell Backbone Router Activation Process The following steps describe conceptual process and flow only Refer to Honeywell s detailed documentation for configuration information Step 1 This process assumes that you have Honeywell One wireless setup installed It includes but is not limited to the Honeywell...

Page 21: ...eviated and is intended only to serve as a introduction Refer to Emerson s WirelessHART Gateway documentation for complete details Figure 1 15 Typical Mesh Configuration Using Cisco 1552WU Access Points with Sensors Table 1 4 The default IP addresses for the WirelessHART Gateway are The WirelessHART Gateway can be configured using a standard web browser and accessing the Gateway s internal webpage...

Page 22: ...ult It is recommended for security purposes that these passwords are changed The administrator password should be appropriately noted when changed If it is lost please contact Emerson Process Management for technical support To change the User Accounts Passwords Step 1 Navigate to Setup Security User accounts Step 2 Set the new password for each role based user account and confirm Step 3 Click Sub...

Page 23: ...90021 1 23 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features Layer 3 Network Operation The access points support Layer 3 network operation Access points and controllers in Layer 3 configurations use IP addresses and UDP packets which can be routed through large networks Layer 3 operation is scalable and recommended by Cisco Figure 1 16 illust...

Page 24: ...s locations mit DC 790021 Fragen zu dem Produkt Kein Problem wir helfen Ihnen per eMail info diskontcomputer com gerne weiter Den aktuellen Preis und Lagerstand finden Sie online auf http www diskontcomputer com detail php item 790021 1 24 Cisco Aironet 1550 Series for Hazardous Locations Installation Guide Chapter 1 Overview Hardware Features ...

Reviews: