C-8
Cisco ME 2400 Ethernet Access Switch Hardware Installation Guide
OL-7678-01
Appendix C Connecting to DC Power
Wiring the DC-Input Power Source
Figure C-10
Torquing the Terminal-Block Captive Screws
Step 7
Repeat Steps 4 and 5 for the remaining three DC-input power source wires.
Figure C-11
shows the
completed wiring of a terminal block plug.
Figure C-11
Completed Wiring of Terminal Block Plug
Step 8
Insert the terminal block plug in the terminal block header on the front panel of the switch.
(See
Figure C-12
).
60533
Torque to 4.5 lbf-in. (72 ozf-in.)
1
Return (positive) Feed A
3
Return (positive) Feed B
2
Supply (negative) Feed A
4
Supply (negative) Feed B
132850
1
2
3
4