2
Installation Notes for Catalyst 3750-E, Catalyst 3560-E Switches and RPS 2300 Power Supply Modules
78-17570-01
Product Overview
Product Overview
Table 1
describes the power supply modules.
Table 2
describes the supported power supply modules for the switches and the RPS 2300.
For more information about which RPS 2300 power supply modules to use for specific switch support,
see the
Cisco Redundant Power System 2300 Hardware Installation Guide
.
The 750-W and 265-W AC power supply modules are autoranging units that support input voltages
between 100 and 240 VAC. The 1150-W power supply module is an autoranging unit that supports input
voltages between 115 and 240 VAC. The DC power supply module has dual input feeds (A and B) and
supports input voltages between 36 and 72 VDC.
The AC power supply modules include a power cord for connection to an AC power outlet. The 1150-W
and 750-W modules use a 16-AWG cord (only North America). All other modules use an 18-AWG cord.
The DC power supply module requires wiring to a DC-power source.
Table 1
Power Supply Module Part Numbers and Description
Part number
Description
C3K-PWR-1150WAC
1150-W AC power supply module
C3K-PWR-750WAC
750-W AC power supply module
C3K-PWR-265WAC
265-W AC power supply module
C3K-PWR-265WDC
265-W DC power supply module
Table 2
Power Supply Modules Used with Switches and RPS 2300
Catalyst 3750-E and
Catalyst 3560-E
Switches and RPS 2300
1150 W AC
Power Supply
750 W AC
Power Supply
265 W AC
Power Supply
265 W DC
Power Supply
48-port PoE switch
1
1.
For full 15.4-W support on a 48-port PoE switch, you must use the 1150-W AC power supply module in the switch.
Primary or spare
Spare or primary
Not allowed
Not allowed
24-port PoE switch
Spare or primary
Primary or spare
Not allowed
Not allowed
48-port non-PoE
switch
Spare
Spare
Primary or spare
Primary or spare
24-port non-PoE
switch
Spare
Spare
Primary or spare
Primary or spare
RPS 2300
2
2.
If only one power supply module is installed in the RPS 2300, you must install the blank insert in the empty power supply
slot.
Primary
Primary
Not allowed
Not allowed