3-50
Cisco Aironet 1552 Series for Hazardous Locations Installation Guide
Chapter 3 Installing the 1552 Series Access Points in Hazardous Locations
Mounting on a Wall or a Pole
Figure 3-2
Location of Access Point Top Support Bolt Hole
Step 4
Position the two bolts on the access point into the quick mount notches on each side of the mounting
bracket (see
Chapter 2, “Pole Mount Installation”
). Ensure that the hinged door is facing out.
Step 5
Screw a M8 x16 bolt (with flat and lock washers) into the second bolt hole on each side of the access
point.
Step 6
Ensure that the front of the access point is vertical, and tighten the four bolts to
13 to 15 ft lbs
(17.6 to 20.3 Nm).
Step 7
When using the Cisco Aironet Dual-Band Omnidirectional Antennas, connect them to the access point
as shown in
. Hand-tighten the antennas to the access point.
Step 8
Continue with the
“Grounding the Access Point (all models)” section on page 3-60
the Access Point” section on page 3-71
1
M8 x16 bolt (supplied with pole mount kit)
3
Ground lug location (M4 x .7)
2
M8 x16 bolt (supplied with pole mount kit)
331879
1
2
3