background image

 

2

Installing the High-Density Electrical Interface Assemblies on the Cisco ONS 15310-MA

78-17418-01

  High-Density EIA Description

Figure 1

 shows the J connectors on the A- and B-side high-density EIAs installed on the ONS 

15310-MA.

Figure 1

High-Density EIA Connectors

Figure 2

 shows the A- and B-side high-density EIAs installed on the ONS 15310-MA.

151584

DS1

OUT

J8

DS1

IN
J9

DS1

OUT

J10

DS1

IN

J11

DS1

OUT

J12

DS1

IN

J13

J20-HD DS3

1

3

2

PWR A

J6-ALM INPUT

J15-IN

J16-OUT

J17-IN

J14-OUT

J18-OUT

J19-IN

PID 

VID

S/N

BAR CODE

CLEI CODE

P/N

COO

-48VDC

RTN

DS1

OUT

J21

DS1

IN

J22

DS1

OUT

J23

DS1

IN

J24

DS1

OUT

J25

DS1

IN

J26

J33-HD DS3

3

1

2

PWR B

J1-LAN

J31-OUT

J30-IN

J29-OUT

J32-IN

J28-IN

J27-OUT

PID VID

S/N

CLEI CODE

BAR CODE

P/N

COO

J2-CRFT

J3-UDC

J4-BITS1

RTN

-48VDC

J5-BITS2

J7-ALM OUT

Summary of Contents for 15310-EIA-HD-A

Page 1: ... EIA Description page 1 Install the High Density EIAs page 3 Related Documentation page 5 Obtaining Documentation and Submitting a Service Request page 5 High Density EIA Description High density EIAs are attached to the ONS 15310 MA shelf assembly backplane to provide up to 168 transmit and receive DS 1 connections through six Champ connectors per side A and B or six transmit and receive DS 3 EC ...

Page 2: ... side high density EIAs installed on the ONS 15310 MA 151584 DS1 OUT J8 DS1 IN J9 DS1 OUT J10 DS1 IN J11 DS1 OUT J12 DS1 IN J13 J20 HD DS3 1 3 2 PWR A J6 ALM INPUT J15 IN J16 OUT J17 IN J14 OUT J18 OUT J19 IN PID VID S N BAR CODE CLEI CODE P N COO 48VDC RTN DS1 OUT J21 DS1 IN J22 DS1 OUT J23 DS1 IN J24 DS1 OUT J25 DS1 IN J26 J33 HD DS3 3 1 2 PWR B J1 LAN J31 OUT J30 IN J29 OUT J32 IN J28 IN J27 OU...

Page 3: ...s for jack screws When installed with the standard door and cabling on the backplane the ONS 15310 MA shelf measures approximately 13 7 inches deep when fully populated with backplane cables Install the High Density EIAs The following parts are needed to install the high density EIAs 2 Phillips screwdriver High density EIA s 6 32 x 5 16 inch pan head screws 3 included with EIA Caution Always use t...

Page 4: ...nnectors Caution Do not firmly apply pressure to the EIA this could damage the EIA and backplane connectors Step 4 Seat the EIA as flat as possible by gently exerting enough pressure with your hands to only partially seat the connectors Do not try and fully insert the EIA Step 5 Locate the two jack screws on the EIA which are found on the opposite corners Figure 2 on page 3 For example on the B si...

Page 5: ...ting a service request and gathering additional information see the monthly What s New in Cisco Product Documentation which also lists all new and revised Cisco technical documentation at http www cisco com en US docs general whatsnew whatsnew html Subscribe to the What s New in Cisco Product Documentation as an RSS feed and set content to be delivered directly to your desktop using a reader appli...

Page 6: ...nded to be actual addresses and phone numbers Any examples command display output network topology diagrams and other figures included in the document are shown for illustrative purposes only Any use of actual IP addresses or phone numbers in illustrative content is unintentional and coincidental 2011 Cisco Systems Inc All rights reserved Printed in the USA on recycled paper containing 10 postcons...

Reviews: