![CISA 59751 Installer'S Instructions Download Page 7](http://html1.mh-extra.com/html/cisa/59751/59751_installers-instructions_2608779007.webp)
7
Diagram 1: example of button/switch connection to panic exit device power supply.
KEY
1
Red | V+ | Power supply (+)
2
Black | V- | Power supply (-)
3
Blue | IN1+ | Input for opening (+)
4
Blue/white | IN1- | Input for opening (-)
5
Button
6
Optional switch for passage mode
12V
+
-
1
2
1
2
3
4
5
6
7
Diagram 2: example of panic exit device connection to an intercom.
KEY
1
Red | V+ | Power supply (+)
2
Black
| V- | Power supply (-)
3
Blue | IN1+ | Input for opening (+)
4
Blue/white | IN1- | Input for opening (-)
5
Lock 12V~
6
Intercom
12V
+
-
5
6
1
2
3
4
Diagram 3: example of panic exit device connection to an intercom using a repeater relay.
KEY
1
Red | V+ | Power supply (+)
2
Black
| V- | Power supply (-)
3
Blue/white | IN1- | Input for opening (-)
4
Blue | IN1+ | Input for opening (+)
5
Lock 12V~
6
Intercom
7
Opening button
8
Relay
12V
+
-
COM A1
NO A2
1
2
4
3
5
6
7
8
Diagram 4: interfacing for panic exit device status (example of installation with an actuator to open and close the door)
KEY
1
Red | V+ | Power supply (+)
2
Black | V- | Power supply (-)
3
Orange | OUT1/C | Lock status securely
locked
4
Orange/white | OUT1/NO |
Lock status securely locked
5
Brown | OUT2/C | Lock status open
6
Brown/white | OUT2/NO | Lock status open
7
Door status locked
8
Door status open
-
+
-
+
12V
+
-
OUT1
OUT2
Max
60V - 0,5A
Max
60V - 0,5A
1
2
3
4
5
6
7
8