CISA 59751 Installer'S Instructions Download Page 1

1

EN

“eFAST TOUCH MORTICE” SERIES  PANIC EXIT DEVICE - Installer’s instruction sheet 
Item 59751 - To be installed with a panic function mortice lock
.

Limit values prescribed by the UNI EN 1125 standard with extension. This product is certified for use on standard and/or fire doors.

> 200

(400 max)

 -10

+50 °C

Max.

1,6 m

Max.

3,5 m

SYMBOLS

Right-handed door (

R

).

Left-handed door (

L

).

Single leaf door (

1

).

Double leaf door (

2

). 

Use of outside access devices (

OD

).

Optional part supplied on request (

OPT

).

L

R

R

            

L

L

R

          

1

          

2

     

   

                  

O

P

T

Check flatness

Place

Align

Use template

See notes

See instructions

Ref. Q.ty

COMPONENTS 

Ref. Q.ty

COMPONENTS 

1

1

Main case

8

1

Spindle 

2

1

Rear support

9

1

Secondary cover 

3

1

Front bracket 

10

1

Bar 

4

1

Rear bracket 

11

1

Rear bar plug 

5

1

Connecting rod 

12

1

Front bar plug

6

1

Main cover 

13

1

Plate

7

2

Main cover plug 

14

1

Connecting cable

8

1

7

6

3

12

10

11

9

2

4

5

= 9 mm

07083-5X-0
07083-75-0
07083-70-0

= 8 mm 07085-76-0

L

13

14

Ref. 

Templates used to position:

A

Main case

D

Rear support

The templates must be cut out and are included in the instruction sheet on page 11.

Small hardware items used

Q.ty = 7

Q.ty = 5

 

O

P

T

 

Summary of Contents for 59751

Page 1: ...on request OPT L R R L L R 1 2 O P T Check flatness Place Align Use template See notes See instructions Ref Q ty COMPONENTS Ref Q ty COMPONENTS 1 1 Main case 8 1 Spindle 2 1 Rear support 9 1 Secondar...

Page 2: ...x xx 1 07074 70 0 XX 1 07076 22 24 26 0 XX A 1 07076 21 23 25 0 XX B 1 06142 8X 0 XX 1 1 07073 20 0 1 1 07176 61 0 XX A 2 1 07176 66 0 XX A 2 Main leaf 1 2 3 A B 2 C MITO PANIC 1 43192 65 0 1 43193 65...

Page 3: ...3 A A D Lx T 2 5 mm D D A Lx L L 600 mm X L Lx L Lx Lx Lx 1 R L 2 R T 3 PANIC EXIT DEVICE LENGTH ADJUSTMENT 6 L 9 2 12 10 12 5 5 10 90 X 0 5 mm X 0 5 mm...

Page 4: ...to check it is fully open 2 Place the rear bracket 4 against the end of the rod 5 4 Connect the power supply cable 14 L 3 1 2 5 5 3 4 2 5 4 T 4 PANIC EXIT DEVICE INSTALLATION CSA 4 2x19 CSF M4x19 CSC...

Page 5: ...d when installing device on fire doors WARNING Do not connect the product directly to the mains 230V CISA declines all responsibility for the compliance of the existing system to current regulations 1...

Page 6: ...ressed the panic exit device opens for 3 seconds this time can be set up to 180 sec on the PC after which it closes and the latchbolts automatically engage 2 Hold open mode the panic exit device can b...

Page 7: ...of panic exit device connection to an intercom using a repeater relay KEY 1 Red V Power supply 2 Black V Power supply 3 Blue white IN1 Input for opening 4 Blue IN1 Input for opening 5 Lock 12V 6 Inte...

Page 8: ...ert the front bar plug inserts 12 in the grooves of the bar 10 CSC 4x8 10 11 12 3 10 9 10 L 4 5 6 Check with the door closed the latchbolt and or tips of the rods enter the strikers correctly 7 Grease...

Page 9: ...the operating strength necessary to work the exit device by using a dynamometer After installation has been completed register the installed product codes and measured operating effort on the Certifi...

Page 10: ...ble guard with spring Art 06525 75 0 75 15 77 6 17 23 260 Art 06515 15 0 Art 06515 20 0 300 mm Art 06515 21 0 600 mm L 22 13 11 35 55 15 2 30 2 87 20 Art 06515 00 0 CERTIFICATES OF CONFORMITY THIS PRO...

Page 11: ...ely for the pur poses indicated therein CISA S p A will not guarantee any performance or technical feature which is not expressly illustrated in these instructions NO modifications can be made to the...

Reviews: