background image

VCC-F60FV19GE 

 

Rev.900-666-32-00

 

 

©2010 CIS Corporation. All rights reserved. 

 

1.    Scope of Application 

This is to describe VCC-F60FV19GE, 5M pixels Gig-E Color CCD Camera.    All specifications contained herein 
are subject to change without prior notice.    Reproduction in whole or in part is prohibited. 

2.    Handling Precautions 

The camera must not be used for any nuclear equipments or aerospace equipments with which mechanical 
failure or malfunction could result in serious bodily injury or loss of human life.    Our warranty does not apply 
to damages or defects caused by irregular and/or abnormal use of the product.     
 
Please observe all warnings and cautions stated below.     
Our warranty does not apply to damages or malfunctions caused by neglecting these precautions. 

 

 

Do not use

 

or store

 

the camera in the following extreme conditions: 

 

Extremely dusty or humid places. 

 

Extremely hot or cold places (operating temperature –5

 to +40

 

Close to generators of powerful electromagnetic radiation such as radio or TV transmitters. 

 

Places subject to fluorescent light reflections. 

 

Places subject to unstable (flickering, etc.) lighting conditions. 

 

Places subject to strong vibration. 

 

Remove dust or dirt on the surface of the lens with a blower. 

 

Do not apply excessive force or static electricity that could damage the camera. 

 

Do not shoot direct images that are extremely bright (e.g., light source, sun, etc.), and when camera   

 

is not in use, put the lens cap on.   

 

Follow the instructions in Chapter 6, “External connector pin assignment” for connecting the camera. 

 

Improper connection may cause damages not only to the camera but also to the connected devices. 

 

Confirm the mutual ground potential carefully and then connect the camera to monitors or computers.     

 

AC leaks from the connected devices may cause damages or destroy the camera. 

 

Do not apply excessive voltage.(Use only the specified voltage.)    Unstable or improper power supply 

 

    voltage may cause damages or malfunction of the camera. 

 

The voltage ripple of camera power DC +12V

±

10% shall be within 

±

50mV.    Improper power 

 

 

supply voltage may cause noises on the video signals.     

 

The rising time of camera power supply voltage shall be less than +10V, Max 60ms.    Please   

 

avoide noises like chattering when rising. 

Summary of Contents for VISION:elite VCC-F60FV19GE

Page 1: ...VCC F60FV19GE Rev 900 666 32 00 2010 CIS Corporation All rights reserved 5M Pixel Color Gig E Camera VCC F60FV19GE Product Specification Operational Manual CIS Corporation English...

Page 2: ...9 6 External Connector Pin Assignment 11 6 1 12 pins Circular Connector HR10 10R 12PA HIROSE 11 6 2 RJ 45 Gigabit Ethernet Connector MOD YSJ88DA03C CN HONDA TSUSHIN KOGYO CO LTD 12 7 Timing Chart 13...

Page 3: ...rs Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration Remove dust or dirt on the surface of the lens with...

Page 4: ...odule utilizing a 2 3 type PS IT CCD 5M pixels CCD image sensor with on chip micro lenses realizes high sensitivity and high resolution At Full Frame Scan Mode entire pixels can be read out within app...

Page 5: ...output Sensitivity F 8 0 2000 lx Shutter speed 1 15s Gain 0dB Minimum illumination F 1 4 15 lx Shutter speed 1 15s Gain Max 18dB Dust or stains in optical system No dust or stain shall be detected on...

Page 6: ...tion 98 m s2 10 0G Frequency 20 200 Hz Direction XYZ 3 directions Testing time 120 min for each direction Shock No mulfunction shall be occurred with 980m s2 100G for X Y and Z 6 directions without pa...

Page 7: ...refer to our VCC G60 F60 GE series startup manual section 5 7 Trigger Mode DVAL output LVTTL 3 3V Output SP Exposure Pulse LVTTL 3 3V Output Trigger input Polarity POSI NEGA Selectable Trigger Pulse...

Page 8: ...al Response Representative Value Lens charcteristics and luminous source charcteristics are not considered 4 4 Image output format Coyote Application Setting 2 Taps Segmented Dual Left Right Inverted...

Page 9: ...1 3200K 2 Spare 3 Spare 4 Manual White Balance Address 156 157 158 and 159 Trigger Mode 004 0 Normal Mode Trigger Mode Off 1 Standard Trigger Mode Shutter speed can be set with address 002 2 Pulse Wid...

Page 10: ...Line 021 022 0 2078 Read Only Total line number at Partial Scan Mode or Full Frame Scan Mode minus 1 is set Manual Digital Gain Right 126 127 256 512 256 x1 0dB 512 x2 6dB Set address 001 data to 004...

Page 11: ...in Program Files Pleora Technologies Inc iPORT Software Documentation Pin No Signals which can be controlled by GigE Camera Control Software 1 GND 2 Power In DC 12V 3 TTL In3 LVTTL Input 5V Tolerant T...

Page 12: ...Yellow LED 6 2 RJ 45 Gigabit Ethernet Connector MOD YSJ88DA03C CN HONDA TSUSHIN KOGYO CO LTD LINK LED Lighting off Unconnected to LAN Lighting on Connected to LAN Blinking Transmitting the data ACT LE...

Page 13: ...CLK FVAL Output 1924CLK 1228CLK CLK 60MHz 2 Tap Output 1 CLK LVAL Output Video Output DVAL Output FVAL Output 1 2 3 4 5 6 7 8 9 10 2076 2075 11 12 21 23 24 CCD Read Out Signal 9 H 21 H 2058 H 12 H Tot...

Page 14: ...re is 1 40 s at RAW mode Trigger input can be accepted even when the camera is outputting video signals However a shutter timing to start the next video output before completion of transferring video...

Page 15: ...40 s Delay time from detecting the trigger edge to completion of exposure is 29 13 s Trigger input can be accepted even when the camera is outputting video signals However a shutter timing to start th...

Page 16: ...0 0H 685 2055H 3H step Effective line register Address 019 020 0 3H 685 2058H 3H step Total line register Address 021 022 706Lines Effective line register 2 2 Read Only Note Reading out position and e...

Page 17: ...ion 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera No is fixed with 6 bite numerical strings 000000 Process code Input any one of R W or C to the process code R read mode is to rea...

Page 18: ...ontrol mode CR Be sure to input CR to confirm the end of the command Note When setting the data with 2 Byte High Byte shall be set first then Low Byte to the next The camera rewrites the internal resi...

Page 19: ...lane 6 3 60 11 1 Screws for tripod attachment Datum Plane 910 003 00 00 Dimension from datum plane to the center of lens mouont The center of effective pixels shall be within f 0 6 to the center of le...

Page 20: ...ct Name Label Position 35 0 1 4 5 0 1 52 GigE DC IN ACT LINK 999 500 00 00 1 2 2 Screw length from C mount lens surface shall be under 6mm And protruding portion shall be lesss than 10mm 1 C Mount scr...

Page 21: ...60FV19GE Rev 900 666 32 00 2010 CIS Corporation All rights reserved 21 CCXC 12PxxN SONY MOD YSP A1AS SP HONDA TSUSHIN KOGYO Cable Reference Drawing 999 500 00 00 2 2 Unit mm 15 17 51 19 31 23 5 MEGA P...

Page 22: ...malfunction or non function of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the instr...

Page 23: ...th time of usage of the products Cause of the CCD pixel defects is the characteristic phenomenon of CCD itself and CIS is exempted from taking any responsibilities for them Should you have any questio...

Reviews: