9.

 

Remote Communication Function 

Via camera link cable, the camera can be controlled.

 

 

(1)

 

The settings for RS232C 

 

Baud rate 

:

 

9600bps (Initial Setting) 
19200bps, 38400bps, 57600bps, 115200bps 

Data 

:

 

8bit 

Stop bit 

:

 

1bit 

Parity 

:

 

None 

XON/XOFF 

:

 

Not controlled 

                 

       

* Baud rate can be changed with address 030.    Please reboot the camera after changing baud rate setting.   

 

(2)

 

Control code 

 

・ 

The total control code is 14 bytes, which conforms to ASCII code. 

 

・ 

The control code consists of camera No. process code, remote controller address, remote   

   controller data, and CR. Execute Read/Write through PC, and the camera will reply the data. 

 

7th Byte 

10 

11 

12 

13 

14 

Camera No. 

Process code 

Remote controller 

address 

Remote controller data 

CR 

000000: fixed 

 

“R” Read mode 

Please refer to the 

address table of Section 

5. Function Settings. 

000

255 

0 Dh 

“W” Write mode 

“C” Camera mode 

00EEEE:4digit error code  “X” Error   

0   

 

    0          0 

0           

 

0              0 

 

Camera number 
 

Camera No. is fixed with 6 bytes numerical strings, “000000”. 

 
Process code 
 

Input any one of R, W, or C to the process code. 

 

R (read mode) is to read the data of remote controller address. 
Please be noted to set any dummy data (000

255) to 11

th

 

13

th

, since a command shall 

consists of 14 bytes. 

 

 

 

W (write mode) is to write the data to the remote controller address. 

 

Please be noted that the data cannot be saved into EEPROM of the camera. 

 

(Reboot the camera, and the data is reset to the initial setting.) 

 

To save the data into EEPROM, please refer to Section 5. Function Settings. 

 
 

C is the code to send the data back from the camera. 

 

Note: Do not set code C when sending the data from PC side. 

Summary of Contents for VCC-GC21FR11PCL

Page 1: ...1FR11PCL Rev 900 761 31 2016 CIS Corporation All rights reserved Camera link I F 4M Resolution CMOS B W Power over Camera Link VCC GC21FR11PCL Product Specification Operational Manual CIS Corporation...

Page 2: ...onfiguration mode 38fps 14 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 38fps 14 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 75fps Initial Setting...

Page 3: ...mely hot or cold places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places...

Page 4: ...ng is set the faster the camera exposure output speed goes and the more the power consumption is required at the same time Power requirement of when the minimum read out line is set with partial scan...

Page 5: ...mber 2048 H x 2048 V 11 264 11 264 mm 1 5 9 3 0 Unit cell size 5 5 m H x 5 5 m V Image Circle 15 930mm 2 Video Output Frequency Pixel Clock 80 MHz 2Tap Base Configuration Mode Horizontal frequency 77...

Page 6: ...9 Partial Scan Full Frame Scan 1 line 1 line step 20 Safety Quality standards UL Conform to UL Standard including materials and others CE EN55022 2010 Class A for Emission EN61000 6 2 2005 for Immunit...

Page 7: ...5us 8Tap Full Configuration mode 1HD 3 225us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Camera Link...

Page 8: ...VCC GC21FR11PCL Rev 900 761 31 2016 CIS Corporation All rights reserved 8 4 3 CMOS Spectral Response Representative Value Lens charcteristics and luminous source charcteristics are not considered...

Page 9: ...9 4 4 Video Output Format 1 2Tap Base Configuration Mode 38fps 2 4Tap Medium Configuration Mode 75fps Initial Setting 3 8Tap Full Configuration Mode 150fps D D 2048 Line 2048pixel 1 2 D D D D 2048 Lin...

Page 10: ...500s 10 1 10000s 1 10000s 1 10000s 11 1 15000s 1 15000s 1 15000s 12 1 20000s 1 20000s 1 20000s 13 1 30000s 1 30000s 1 30000s 14 1 30000s 1 40000s 1 40000s 15 1 30000s 1 40000s 1 50000s 16 Manual Shutt...

Page 11: ...utter Speed 16 641us 2048 036 037 12 9us Min value 0 26 436ms 1 38s Max value 2047 29 541us 1 30000s 4Tap mode Shutter Speed 16 641us 2048 036 037 6 45us Min value 0 13 226ms 1 75s Max value 2047 23 0...

Page 12: ...line numbers 5 088 089 1 2048 Set 0 when not in use Partial scan effective line numbers 6 090 091 1 2048 Set 0 when not in use Partial scan effective line numbers 7 092 093 1 2048 Set 0 when not in u...

Page 13: ...er line of the Medium or Full configuration connector side shall be kept open Do not plug and unplug the camera link cables since it may cause the camera malfunction Pin No Pin No Pin No Pin No 1 GND...

Page 14: ...00 761 31 2016 CIS Corporation All rights reserved 14 7 Timing Chart 7 1 Horizontal Synchronous Signals Timing 2Tap Base Configuration mode 38fps 7 2 Vertical Synchronous Signals Timing 2Tap Base Conf...

Page 15: ...761 31 2016 CIS Corporation All rights reserved 15 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 75fps Initial Setting 7 4 Vertical Synchronous Signals Timing 4Tap Medium C...

Page 16: ...L Rev 900 761 31 2016 CIS Corporation All rights reserved 16 7 5 Horizontal Synchronous Signals Timing 8Tap Full Configuration Mode 150fps 7 6 Vertical Synchronous Signals Timing 8Tap Full Configurati...

Page 17: ...etecting trigger edge in the camera to starting exposure is max 1HD Triggers can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prio...

Page 18: ...m detecting trigger end edge to completing exposure is max 1HD Pulse width is min 1HD to approx 2 frames Functionally there is no upper limitation but noises such as dark noises and shadings may be no...

Page 19: ...ideo Out Partial Scan Setting Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2 A...

Page 20: ...ne Time for 1 line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 12 9us 4Tap Medium Configuration Mode 6 45us 8Tap Full Configuration Mode 3 225us Setting Example Line numbers at partial sc...

Page 21: ...Process code Remote controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode 00EEE...

Page 22: ...l mode CR Be sure to input CR to confirm the end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the...

Page 23: ...VCC GC21FR11PCL Rev 900 761 31 2016 CIS Corporation All rights reserved 23 11 CMOS Optical Axis Accuracy...

Page 24: ...VCC GC21FR11PCL Rev 900 761 31 2016 CIS Corporation All rights reserved 24 12 Dimensions...

Page 25: ...his product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified In case damage or loss...

Reviews: