VCC-GC20U11PCL
Rev.900-733-33
©2015 CIS Corporation. All rights reserved.
16
LVAL Output
Video Output
DVAL Output
1H = 1025 CLK
0
1
2
3
2044
2045
5CLK
N/2 CLK
LVAL Output
· At full frame scan
· At horizontal partial scan
Video Output
S
S+1
S+2
S+3
S+4
S+6
S+N
S+N
- 1
· · · · ·
S+N
-2
S+N
- 3
512
513
514
515
1532
1533
1534
1536
· · ·
· · ·
· · ·
Partial scan (Horizontal 1/2) S:
514CLK
Manual partial scan S: Any
Partial scan (Horizontal 1/2) N 1020CLK
Manual partial scan N: Any
2046
2047
Sensor effective pixels = 2048
Horizontal partial scan
Starting position setting rante
0~ 1308
S = 1308 (with limitation)
Horizontal partial scan
Starting position set value
N = 740
(Horizontal partial scan
when 10 is set as output pixels )
0
1308
1318
S = 1318(Invalid)
Horizontal partial scan
Starting position set value
9.
Partial Scan Mode
9.1.
Horizontal Partial Scan
S:
Horizontal partial scan starting position (address 023
&
024)
N:
Output pixels (Output pixels = 640+Horizontal partial scan output pixels set value (address 027) x 10)
Scan Mode (address:005)
S
N
Horizonal Sync. Frequency (kHz)
0:Full frame scan mode
0
2050 77.66
1:Partial scan mode (Horizontal 1/2, Vertical 1/2) 514
1020 155.32
2:Manual partial scan mode
Any
Any
79.99MHz /((output pixels/2 tap) + 5)
・
The max value of horizontl partial scan starting position is limited with the formula below since output pixel number has priority.
The max value of horizontal partial scan starting position =2048 (sensor effective pixels) –
output pixel number
Output pixel number = 640 + (horizontal partial scan output pixel set value x 10)
(Ex.) When 10 is set as horizontal partial scan output pixel number, the max value of horizontal partial scan starting position will
be 2048 – (640 + 10 x10) = 1308.
If horizontal partial scan starting position is set to 1318 with this time, output pixel number has priority so that horizontal
partial scan starting position shall be limited to 1308.