VCC-GC10V31L
Rev.900-685-31-00
©2009 CIS Corporation. All rights reserved.
15
Remote controller address
Note: Do not save the data into the address other than specified, since it may cause the
damages or malfunction of the camera.
Remote controller data
Set the decimal number (000
~
255) for the remote controller data. Please be noted to set any
dummy data at read mode.
CR
Be sure to input “CR” to confirm the end of the command.
※
10ms should be waited to send the next command after receiving the response from the camera when
changing the mode in succession.
9. Initial Settings
Function
Address
Data
Gain 001
0:0dB
E-Shutter 002
0:1/60s
(OFF)
Trigger Mode
004
0: Normal Shutter Mode (Trigger OFF)
Scan Mode
005
0: Full Frame Scan Mode
Partial Scan Manual Start Position
006 & 007 4: 1 line
Manual Gain Control
008
0:0dB
Manual Shutter Control
009 & 010 4:1/60s (OFF)
Trigger Polarity
011
0: Positive Input
Flip
013
0:Normal Output Mode