background image

 

 

900-548-30-00 

10

Camera No. shall consist of 6 bytes of characters/numeric strings. 
 

Send the individual camera number code or common number code, “000000”. 

 

The reply data from the camera shall contain the registered number for that camera. 

 
Process code 
 

Input any one of R, W, or C to the process code. 

 

R (read mode) is to read the data of remote controller address. 
 Please be noted to set any dummy data (000

255) to 11

th

 

13

th

, since a command shall 

consists of 14 bytes. 
W (write mode) is to write the data to the remote controller address. 
Please be noted that the data cannot be saved into EEPROM of the camera. 
(Reboot the camera, and the data is reset to the initial setting.) 
To save the data into EEPROM, please refer to Clause 5.4. Function Setting. 
Note: Once the data was saved into EEPROM, it may not be reset to t he initial 
settings

 
C is the code to send the data back from the camera. 
Note: Do not set code C when sending the data from PC side. 

 
Remote controller address 

 Note: Do not save the data into the address other than specified, since it may cause 
the damages or malfunction of the camera. 

 
Remote controller data 

 Set the decimal number (000

255) for the remote controller data.    Please be noted to set any 

dummy data at read control mode. 

 
CR 
 

Be sure to input “CR” to confirm the end of the command. 

Summary of Contents for VCC-G22S21CL

Page 1: ...900 548 30 00 1 English SXGA B W Camera 49MHz Pixel Clock Camera Link VCC G22S21CL Product Specification Operation Manual CIS Corporation...

Page 2: ...9 6 External Connector Pin Assignment 11 6 1 6 pins Circular Connector HR10 7R 6PA HIROSE 11 6 2 26 pins Compact Camera Link Connector 12226 1100 00 PL 3M 11 7 Safety Quality Standards 12 8 Durability...

Page 3: ...Precautions 3 Product Outline VCC G22S21CL is a high resolution industrial B W digital video camera module utilizing a 1 2 inch PS IT CCD 1450K CCD image sensor with on chip micro lenses realizes high...

Page 4: ...Output 26pin Camera Link Connector Camera Power Supply 6pin or 12pin Circular Connector Recommended Ripple Voltage under 500 V Same ripple voltage applies when supplying power to frame grabber board...

Page 5: ...xed Optical axis accuracy Refer to Clause 10 CCD Optical Axis Accuracy Video output signal Digital RAW data 8 bit 10bit Camera Link output Base Configuration 8 bit Output Port A 10 bit Output Port A B...

Page 6: ...mera Link connector HR10A 7R 6PA Trigger input Min Trigger Pulse width Over 2 HD Digital 8bit Digital 10bit White Clip Level FF 3FF Setup Level 08 03 020 00C Dark Shading Under 10h for both horizontal...

Page 7: ...rt C4 No Data Port A5 D5 Port B5 No Data Port C5 No Data Port A6 D6 Port B6 No Data Port C6 No Data Port A7 D7 Port B7 No Data Port C7 No Data 10 bit Data output Port bit Data bit Port bit Data bit Po...

Page 8: ...Trigger Mode Shutter speed can be set by pulse width 3 No function No Function 005 007 No Function Manual Gain Control 008 0 255 1dB 12dB Set the data of address 001 to 004 Manual Shutter Control 009...

Page 9: ...n of circular connector or 26 pin of camera link connector the camera can be controlled by external PC 1 The settings for RS 232C are as follows Baud rate 9600 bps Data 8 bits Start bit 1 bit Stop bit...

Page 10: ...that the data cannot be saved into EEPROM of the camera Reboot the camera and the data is reset to the initial setting To save the data into EEPROM please refer to Clause 5 4 Function Setting Note Onc...

Page 11: ...essor models 6 2 26 pins Compact Camera Link Connector 12226 1100 00 PL 3M Pin No 1 Power IN 12V 2 TTL Trigger IN 3 RS 232C RXD 4 RS 232C TXD 5 Do not connect 6 GND Pin No Pin No 1 GND 14 GND 2 X0 15...

Page 12: ...d operation 8 Durability Item Specification Remarks Vibration resistance Acceleration 98 m s2 10 0G Vibration frequency 11 200 Hz Sine wave Sweep interval 300 sec Direction XYZ 3 directions Testing ti...

Page 13: ...1068 1 2 3 4 5 6 7 8 9 10 11 12 13 14 16 17 18 19 25 26 27 28 LVAL OUT FVAL OUT DVAl OUT Read out signal Discharge signal Video signal 9H 8H Exposure time 1046 1047 1048 1049 1050 1051 1052 1053 1054...

Page 14: ...LVAL OUT FVAL OUT DVAL OUT V PULSE Read out signal Video signal Discharge signal Jitter 1H max Exposure Time Trigger width 2H min Triggger input signal 1 9 17 23 517 9H 8H 1040H LVAL OUT FVAL OUT DVA...

Page 15: ...pulse Exposure will be started from the 428th CLK 38CLK 428CLK START EXPOSURE Trigger input signal LVAL out Discharge sinal When pulse width trigger mode H V Sync reset is selected exposure will be co...

Page 16: ...0 3 10 0 3 29 M2 M3 M2 Datum Plane The center of effective pixels shall be within 0 6 to the center of lens mount Inclination of effective pixels to datum plane shall be 0 5 Dimension from datum plan...

Page 17: ...11 Dimensions 900 548 30 00 17 29 29 G22S21CL SXGA 41 12 29 DC IN 12 2 M3 Depth 4 5 999 427 00 00 3 4 5 12 20 3 M3 Depth 3 Model Name Plate Position 4 M2 Depth 3 28 23 7 M3 22 M2 C mount...

Page 18: ...of the equipment we shall be exempted from responsibility for such damages In case damage or losses are caused by failure to observe the information contained in the instructions in this product speci...

Page 19: ...ght source sun etc and when camera is not in use put the lens cap on Follow the instructions in Chapter 6 External connector pin assignment for connecting the camera Improper connection may cause dama...