background image

VCC-FC21U19PCL 

 

Rev. 900-762-31 

   

©2016 CIS Corporation. All rights reserved. 

11 

 

 
Function 

Address 

Data 

Table Selection for Gain CC 
Control 

024 

0

7: 

CC2 

CC3 

CC4 

0: 

1: 

2: 

3: 

4: 

5: 

6: 

7: 

Table  Read/Write  for  Gain 
CC Control 

025 

0: 

Nop 

1: 

Table Read 

2: 

Table Write 
The  following  manual  gain  is  written  in  to  the  table  specified  with 
Address 024. 
Manual Gain (Address 032&033),   
Manual WB R (Address 046&047), Manual WB B (Address 048&049), 
and Manual WB G (Address 050&051). 

3: 

Clear Table 

Baud Rate 

030 

0: 

9600bps 

1: 

19200bps 

2: 

38400bps 

3: 

57600bps 

4: 

115200bps 

Camera Mode 

031 

0: 

8Tap Full Configuration Mode (280fps) 

1: 

4Tap Medium Configuration Mode (140fps) 

2: 

2Tap Base Configuration Mode (70fps) 

Manual Gain   

032&033 

0

767: 

0:0dB 

767:+12dB 

Manual Shutter 

036&037 

0

1087:   

2Tap mode: Shutter Speed

 

=

 

16.641us + (1088 - (036&037))

×

12.9us 

Min. value    0: 14.052ms(1/70s),    Max. value    1087: 29.541us(1/30000s) 

4Tap mode: Shutter Speed

 

=

 

16.641us + (1088 - (036&037))

×

6.45us 

Min. value    0: 7.034ms(1/140s),    Max. value      1087:23.091us(1/40000s) 

8Tap mode: Shutter Speed

 

=

 

16.641us + (1088- (036&037))

×

3.225us 

Min. value    0: 3.525ms(1/280s),    Max. value    1087: 19.866us (1/50000s) 

Set the data of the address 002 to 016.     

Manual White Balance R 

046&047 

0

767: 

0:0dB 

  767:+12dB 

 

Set the data of the address 003 to 004. 

Manual White Balance B 

048&049 

0

767: 

0:0dB 

  767:+12dB 

 

Set the data of the address 003 to 004. 

Manual White Balance G 

050&051 

0

767: 

:0dB 

  767:+12dB 

 

Set the data of the address 003 to 004. 

Cursor Indication ON/OFF  058 

0: 

OFF 

1: 

ON 

Cursor X Address 

061&060 

0

2047:   

Cursor Y Address 

063&062 

0

1087:   

Summary of Contents for VCC-FC21U19PCL

Page 1: ...VCC FC21U19PCL Rev 900 762 31 2016 CIS Corporation All rights reserved Camera link I F 2M Resolution CMOS Color RAW PoCL VCC FC21U19PCL Product Specification Operational Manual CIS Corporation English ...

Page 2: ...onfiguration mode 70fps 14 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 70fps 14 7 3 Horizontal Synchronous Signals Timing 4Tap Medium Configuration Mode 140fps Initial Setting 15 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 140fps 15 7 5 Horizontal Synchronous Signals Timing 8Tap Full Configuration Mode 280fps 16 7 6 Vertical Synchronous Signals T...

Page 3: ...emely hot or cold places operating temperature 5 to 45 Close to generators of powerful electromagnetic radiation such as radio or TV transmitters Places subject to fluorescent light reflections Places subject to unstable flickering etc lighting conditions Places subject to strong vibration Remove dust or dirt on the surface of the lens with a blower Do not apply excessive force or static electrici...

Page 4: ...ng is set the faster the camera exposure output speed goes and the more the power consumption is required at the same time Power requirement of when the minimum read out line is set with partial scan will be approx 1 5 times more than the one with full frame scan Naturally heat of the camera will be increased Especially when the read out line is set in the range of 100 lines to 1 line heat dissipa...

Page 5: ...2048 H x 1088 V 11 264 5 984 12 775 単位 mm Unit cell size 5 5μm H x 5 5μm V Image Circle φ 12 775mm 2 Video Output Frequency Pixel Clock 80 MHz 2Tap Base Configuration Mode Horizontal frequency 77 519 kHz Horizontal clock 1032 CLK Vertical frequency 70 217 Hz Scanning lines 1104 H 4Tap Medium Configuration Mode Horizontal frequency 155 039 kHz Horizontal clock 516 CLK Vertical frequency 140 434 Hz ...

Page 6: ...Shutter Trigger Mode Pulse Width Shutter Trigger Mode 21 Partial Scan Full Frame Scan 1 line 1 line step 22 Safety Quality standards UL Conform to UL Standard including materials and others CE EN55022 2010 Class A for Emission EN61000 6 2 2005 for Immunity RoHS Conform to RoHS FCC To be applied to FCC Class A digital Device This device complies with Part 15 of the FCC Rules Operation is subject to...

Page 7: ...45us 8Tap Full Configuration mode 1HD 3 225us Functionally no upper limitation is set but noises such as dark noises and shadings might be noticeable at long time exposure Trigger Input CC1 Camera Link input LVDS 5 Serial Communication SerTC Serial to Camera Camera Link input LVDS SerTFG Serial to Frame Grabber Camera Link output LVDS 6 Video Signals White Clip Level At Digital 10bit At Digital 8b...

Page 8: ...VCC FC21U19PCL Rev 900 762 31 2016 CIS Corporation All rights reserved 8 4 3 CMOS Spectral Response Representative Value Lens characteristics and luminous source characteristics are not considered ...

Page 9: ...9 4 4 Video Output Format 1 2Tap Base Configuration Mode 70fps 2 4Tap Medium Configuration Mode 140fps Initial Setting 3 8Tap Full Configuration Mode 280fps 1088 Line 2048pixel 1 G B 2 1088 Line 2048pixel G B G B 1 2 3 4 1088 Line 2048pixel G B G B G B G B 1 2 3 4 5 6 7 8 ...

Page 10: ...0s 12 1 20000s 1 20000s 1 20000s 13 1 30000s 1 30000s 1 30000s 14 1 30000s 1 40000s 1 40000s 15 1 30000s 1 40000s 1 50000s 16 Manual Shutter Refer to Address 036 and 037 White Balance 003 0 Through 1 3200K 2 Through 3 Through 4 Manual White Balance Refer to the address 046 047 048 049 and 050 051 Trigger Shutter Mode 004 0 Normal Shutter Mode Trigger OFF 1 Fixed Trigger Shutter Mode Shutter speed ...

Page 11: ...s 2 2Tap Base Configuration Mode 70fps Manual Gain 032 033 0 767 0 0dB 767 12dB Manual Shutter 036 037 0 1087 2Tap mode Shutter Speed 16 641us 1088 036 037 12 9us Min value 0 14 052ms 1 70s Max value 1087 29 541us 1 30000s 4Tap mode Shutter Speed 16 641us 1088 036 037 6 45us Min value 0 7 034ms 1 140s Max value 1087 23 091us 1 40000s 8Tap mode Shutter Speed 16 641us 1088 036 037 3 225us Min value ...

Page 12: ... 1088 Set 0 when not in use Partial scan effective line numbers 3 084 085 1 1088 Set 0 when not in use Partial scan effective line numbers 4 086 087 1 1088 Set 0 when not in use Partial scan effective line numbers 5 088 089 1 1088 Set 0 when not in use Partial scan effective line numbers 6 090 091 1 1088 Set 0 when not in use Partial scan effective line numbers 7 092 093 1 1088 Set 0 when not in u...

Page 13: ...er line of the Medium or Full configuration connector side shall be kept open Do not plug and unplug the camera link cables since it may cause the camera malfunction Pin No Pin No Pin No Pin No 1 GND 12V PoCL 14 GND 1 NA 14 GND 2 X0 15 X0 2 Y0 15 Y0 3 X1 16 X1 3 Y1 16 Y1 4 X2 17 X2 4 Y2 17 Y2 5 Xclk 18 Xclk 5 Yclk 18 Yclk 6 X3 19 X3 6 Y3 19 Y3 7 SerTC 20 SerTC 7 100Ω 20 Terminated 8 SerTFG 21 SerT...

Page 14: ...Tap Base Configuration mode 70fps 7 2 Vertical Synchronous Signals Timing 2Tap Base Configuration Mode 70fps FVAL Out 1Frame 1104H 14 242ms Effective Line 1088H Effective Line DVAL Out LVAL Out Effective Line V Blanking 16H Read Out Pulse Exposure Time Address 036 037 SP Out Exposure Out 1 0 8 8 1 0 8 8 1 1 1H 12 9us Video Out 10 H ...

Page 15: ...uration Mode 140fps Initial Setting 7 4 Vertical Synchronous Signals Timing 4Tap Medium Configuration Mode 140fps FVAL Out 1Frame 1104H 7 121ms Effective Line 1088H Effective Line DVAL Out LVAL Out Effective Line V Blanking 16H Read Out Pulse Exposure Time Address 036 037 SP Out Exposure Out 1 0 8 8 1 0 8 8 1 1 1H 6 45us Video Out 7 H ...

Page 16: ... Configuration Mode 280fps 7 6 Vertical Synchronous Signals Timing 8Tap Full Configuration Mode 280fps FVAL Out 1Frame 1104H 3 560ms Effective Line 1088H Effective Line DVAL Out LVAL Out Effective Line V Blanking 16H Read Out Pulse Exposure Time Address 036 037 SP Out Exposure Out 1 0 8 8 1 0 8 8 1 1 1H 3 225us Video Out 1 H ...

Page 17: ...output prior to the completion of video transmission for the prior video output signals cannot be accepted If the next trigger is input prior to the completion of video transmission for the prior video output signals the image may be impacted Trigger input during exposure time should be ignored Refer to the below A Effective Line 1088H Effective Line SP Out Exposure Out 1 0 8 8 1 TRIG IN Read Out ...

Page 18: ...ay be noticeable at long time exposure Triggers can be accepted even when outputting video signals However trigger signals for exposure to start the next video output prior to the completion of video transmission for the prior video output signals cannot be accepted If the next trigger is input prior to the completion of video transmission for the prior video output signals the image may be impact...

Page 19: ...ideo Out Partial Scan Setting Partial scan start position 1 Address 064 065 Partial scan start position 3 Address 068 069 Partial scan effective lines 2 Address 082 083 Partial scan start position 2 Address 066 067 Partial scan effective lines 3 Address 084 085 0 2047 Partial scan effective lines 1 Address 080 081 Partial scan effective lines 2 Address 082 083 Partial scan effective lines 3 Addres...

Page 20: ... line numbers x Time for 1 line Time for 1 line Camera Mode Time for 1 Line 2Tap Base Configuration Mode 12 9us 4Tap Medium Configuration Mode 6 45us 8Tap Full Configuration Mode 3 225us Setting Example Line numbers at partial scan setting can be set from 1 line However consumption current will increase several hundreds mA more so that the margin of camera power capacity shall be considered Effect...

Page 21: ... 11 12 13 14 Camera No Process code Remote controller address Remote controller data CR 000000 fixed R Read mode Please refer to the address table of Section 5 Function Settings 000 255 0 Dh W Write mode C Camera mode Camera number Camera No is fixed with 6 bytes numerical strings 000000 Process code Input any one of R W or C to the process code R read mode is to read the data of remote controller...

Page 22: ...sure to input CR to confirm the end of the command Note The data set with 2 Byte shall be set with High Byte even address first then set with Low Byte odd address The camera rewrites the internal resister when receiving Low Byte 3 Data Save Input data 083 or 053 into the address 127 to save the data to EEP ROM 4 Initial Settings Input data 083 or 053 into the address 126 to return to the initial s...

Page 23: ...VCC FC21U19PCL Rev 900 762 31 2016 CIS Corporation All rights reserved 23 11 CMOS Optical Axis Accuracy ...

Page 24: ...VCC FC21U19PCL Rev 900 762 31 2016 CIS Corporation All rights reserved 24 12 Dimensions ...

Page 25: ...his product specification operation manual In case damage or losses are caused by malfunction or other problems resulting from use of equipment or software that is not specified In case damage or losses are caused by repair or modification conducted by the customer or any unauthorized third party such as an unauthorized service representative Expenses we bear on this product shall be limited to th...

Reviews: