VCC-2CXP6R
Rev.905-0187-02
©2019 CIS Corporation. All rights reserved.
8
4.2.
Vertical Sync. Timing
FVAL Out
Effective Line : 1248H
DVAL Out
~ ~
Effective Line
~ ~
Exposure Time
SP Out
(Exposure Out)
1
2
4
8
1
2
4
8
1
1
Video Out
Effective Line
Invalid
Line
Effective Line
Invalid
Line
V Blank
Don’t
care
Don’t
care
※ The time for 1frame shall be changed depends on the link rate and video output format.
※ The blanking line number for 1frame shall be changed depends on the link rate and video output format.
Effective line numbers and blanking line numbers
Video output
format
CXP-3
BayerRG/Mono8
1248
68
1316
6.36
8.37
BayerRG/Mono10 1248
68
1316
7.81
10.28
BayerRG/Mono12 1248
64
1312
9.21
12.08
CXP-6
BayerRG/Mono8
1248
68
1316
3.18
4.18
BayerRG/Mono10 1248
68
1316
3.91
5.15
BayerRG/Mono12 1248
64
1312
4.61
6.05
Sensor Operation clk
74.25 MHz
Time for 1frame [ms]
Link rate
Effective
Line
V blank
1frame total
line number
Time for 1H [us]