DISASSEMBLY
(see figure)
HALKEY ROBERTS CORPORATION AUTOMATIC/MANUAL
(6F)
Step 8: Install cylinder by rotating clockwise into inflator until cylinder is secured
firmly in inflator
Step 9: Place indicator clip over red lever by aligning the arms on the clip with the
slots in the inflator.
Push firmly in the middle of the clip to snap in place.
Step 10: Check to be sure service indicator is green and green indicator clip is
firmly attached.
Step 6: IMPORTANT!
Bobbin (Yellow) must be installed into the Housing (**see figure), white side down
facing away from the inflator
towards the cap (clear), aligning the slots on the bobbin
with the ridges
inside the threaded housing. The bobbin will slide in easily if installed
correctly.
Step 7: Install cap by screwing clockwise until it meets the housing shoulder.
Note: No gap.
P.4
SERVICE INSTRUCTIONS
CO2 Cylinder
Bobbin
(Yellow)
Housing
Indicator
Clip
Step 2 Step 8
Step 3 Step 7
Step 10
Step 5 Step 6
Step 9
Step 10
Red lever
Step 9
Step 6
Jerk
clockwise
If red, stop and service unit
If green, and clip is present, unit is operable.
**
Cap
(Clear)
Service Indicator - Step 10
SERVICE INSTRUCTIONS: ALPHA 90000
Step 1: Unpack or open the life
vest so that the manual/ automatic
inflator is visible
Step 2: Remove gas CO2 cylinder by
firmly rotating cylinder counter -
clockwise. Discard cylinder.
Step 3: Remove clear cap by turning
counter-clockwise.
Step 4: Remove bobbin from cap or
housing unit. Discard bobbin (yellow).
Check the housing to be sure it is
clear and dry.
Note: The bobbin (yellow) body may remain in the
housing or in the cap assembly when you remove
the cap. The bobbin body must be removed prior
to assembly.
Rearming
Note: Rearming must follow the sequence below.
Step 5: Check the date on the bobbin in the rearm
kit. The date should not be over three (3) years
from today’s date.
INFLATOR