Cirris Systems | Setting up the CR Tester 10
Installing more than 7 Add-on Scanners
After the first seven add-on scanners have been installed, you must use a Booster Scanner for each
additional set of seven Add-ons. You can have a maximum of 125 scanner boxes for a total 32,000
test points. Booster stacks can be separated up to 200 feet using an approved interface cable and
depending on working conditions and environment.
1.
Connect an Add-on Cable to each Add-on
Scanner as shown.
2.
Connect a Booster Cable from the base
Scanner
“Booster Out” connector to the
Booster Scanner
“Booster In” connector.
Warning!
If you attach the Booster cable to the
Add-on Out connector, you may damage your
system!
3.
Connect a terminator to each unused
connector port as shown.
4.
Make sure to plug all the power cords and the
computer into the same grounded power strip.
For large systems, do the following:
Chain the plug strips together to ensure
consistant grounding. Don’t worry about
overloading power cords; a 125 scanner box
system uses less than 200 watts of power.
To computer
To grounded
wall outlet
Add-On
Cables
Base Scanner
Booster Cable
Terminators
Booster
Scanner
To Scanners
Correct
Placement