background image

–  9  –

Specifications

PSC-520

PSC-336

PSC-260

Input Voltage

90-130VAC, 60Hz

Full Load Input Current at 120VAC

1.8A

Output Voltage Adjustable Range

1.0 - 20Vdc

1.0 – 36Vdc

1.0 - 60Vdc

Output Current Adjustable Range

0 - 5A

0 - 3A

0 - 1.6A

Voltage Regulation

      Load from 10% to 100% Variation

120mV

50mV

50mV

      Line from 90 to 130VAC Variation

20mV

      Ripple & Noise in r.m.s.

5mV

8mV

      Ripple & Noise (peak to peak)

30mV

50mV

100mV

Current Regulation

      Load from 10% to 100% Variation

20mA

      Line from 90 to 130VAC Variation

20mA

      Ripple & Noise (peak to peak)

70mA

20mA

20mA

Switching Operation Frequency

80KHz to 120KHz

Power Factor

0.65

Efficiency at Maximum Power

80%

80%

78%

Volt and Amp Control Type

Rotary Encoder

Voltmeter and Ammeter Display

4 Digit

Voltmeter Accuracy

±0.5% +5counts 
for range V

5V

±0.5% +3counts 
for range V>5V

±0.5% +5counts 
for range V

10V

±0.5% +3counts 
for range V>10V

±0.5% +5counts 
for range V

20V

±0.5% +3counts 
for range V>20V

Ammeter Accuracy

±0.5% +5counts 
for range I

2A

±0.5% +3counts 
for range I>2A

±0.5% +5counts 
for range I

1A

±0.5% +3counts 
for range I>1A

±0.5% +5counts 
for range I

0.5A

±0.5% +3counts 
for range I>0.5A

LCD Indication

CC, CV, Amp, Volt, Output ON-OFF

Protection

Short Circuit, Overload, Over Temperature, Tracking OVP

Cooling System

Natural Convection

Dimensions (WxHxD)

70 x 150 x 250 mm / 2.8 x 6.0 x 9.8 in

Weight

2 kg / 4.4 lb

Summary of Contents for PSC-260

Page 1: ...OPERATION MANUAL CIRCUIT TEST Switching Mode Power Supply PSC 260 PSC 336 PSC 520 ...

Page 2: ...PSC 260 336 520 08R13 ...

Page 3: ...r supply or connected equipment CAUTION Failure to observe this warning may result in damage to equipment and Improper functioning of the power supply Warning 1 Do not use this power supply near water 2 Do not operate or touch this power supply with wet hands 3 Do not open the casing of the power supply when it is con nected to ac mains 4 Refer all servicing to qualified service personnel only 5 B...

Page 4: ...wer cable must be at least 0 75mm2 and the total length of power cable must not exceed 3m Operation Environmental Condition 10 80 R H Maximum relative humidity 80 for temperature up to 31 C decreasing linearly to 50 relative humidity at 40 C Altitude up to 2000m Installation category CAT 2 Pollution degree 2 Mains supply voltage fluctuation up to 10 of the normal voltage Introduction This series o...

Page 5: ...and fine tuning Output Current Tuning knob Push the knob to toggle the coarse and fine tuning Output On Off push button Output Terminal Positive Red color GND Terminal Green color Chassis ground terminal nor mally this is to be short to or as required by user Output Terminal Negative Black color LCD Display panel showing 4 digit voltage current meter CV constant voltage mode CC constant current mo...

Page 6: ... power supply is designed to operate as a constant voltage source or as a constant current source Automatic crossover to either mode of operation occurs when the load condition changes as following CONSTANT VOLTAGE CV AUTOMATIC CROSSOVER CONSTANT CURRENT CC The power supply functions as a constant voltage source CV as long as the load current is less than the preset current limiting value When the...

Page 7: ... on the power supply and the LCD display should be on at the same time 3 The CV icon should be shown on the display 4 Turn to current volume knob 5 to maximum clockwise if you do not require lower Current limiting value otherwise do the preset the CC limiting procedure 5 Set your desired output voltage and then turn off the output terminal by push button 6 6 Connect to your load positive to positi...

Page 8: ...voltage value at the time of the operation OVER TEMPERATURE PROTECTION When the temperature inside the power supply becomes higher than a pre determined value the output voltage and current of the power supply will automatically decrease to zero to prevent dam age to power supply When the temperature inside the power sup ply returns to about 65 C then the power supply will automatically return to ...

Page 9: ...ion Frequency 80KHz to 120KHz Power Factor 0 65 Efficiency at Maximum Power 80 80 78 Volt and Amp Control Type Rotary Encoder Voltmeter and Ammeter Display 4 Digit Voltmeter Accuracy 0 5 5counts for range V 5V 0 5 3counts for range V 5V 0 5 5counts for range V 10V 0 5 3counts for range V 10V 0 5 5counts for range V 20V 0 5 3counts for range V 20V Ammeter Accuracy 0 5 5counts for range I 2A 0 5 3co...

Page 10: ...CIRCUIT TEST ELEC TRONICS Division of R P Electronic Components Ltd BURNABY BC CANADA V5J 5M8 ...

Reviews: