- 11 -
MAX/MIN
NOTE:
When using the MAX/MIN function in Autoranging mode, the meter will
“lock” into the range that is displayed on the LCD when MAX/MIN is activated.
If a MAX/MIN reading exceeds that range, an “
OL
” will be displayed. Select
the desired range BEFORE entering MAX/MIN mode.
1. Press the
MAX/MIN
key to activate the MAX/MIN recording mode. The
display icon "
MAX
" will appear. The meter will display and hold the
maximum reading and will update only when a new “max” occurs.
2. Press the
MAX/MIN
key again and the display icon "
MIN
" will appear.
The meter will display and hold the minimum reading and will update
only when a new “min” occurs.
3. To exit MAX/MIN mode press and hold the
MAX/MIN
key for 2 seconds
Display Backlight
Press and hold the
HOLD
key for >1 second to turn on or off the display
backlight function. The backlight will automatically turn off after 10 seconds.
HOLD
The hold function freezes the reading in the display. Press the
HOLD
key
momentarily to activate or to exit the
HOLD
function.