background image

INTRODUCTION

Your Circuit-Test DMR-1100 Digital Multimeter incorporates the latest technology to
provide you with a feature packed instrument. With it you can measure a wide range
of voltages, current and resistance in the lab, shop, car and home. This product has
been designed for the electrician, technician and hobbyist.

FEATURES

Continuity Buzzer - easily check for continuity.

Diode Check - test diodes and other semiconductors for open and short circuits.

Overload Protection - protects the meter from overvoltage and incorrect range
selection.

Auto-Polarity - indication on display that polarity is reversed.

WARNING

1.

Set the function switch correctly before making any measurements.

2.

Do not operate the unit unless the case is completely closed.

3.

Disconnect test leads from equipment before removing the battery.

4.

Never connect unit to AC or DC powered circuits when function switch is set to 

,

diode check or continuity.

5.

To safeguard against electrical shock or damage to instrument, never connect to
more than 1000V DC or 750V AC between input jacks and ground.

6.

Always inspect the instrument, test leads and other accessories for damage prior to
use.

7.

Read this instruction manual carefully and completely before using.

SAFETY PRECAUTIONS

High voltage AC and DC circuits are dangerous. Always consider circuits to be energized.
Never assume any equipment is de-energized. Lack of caution or poor safety practices
can be very dangerous and/or lethal.

SPECIFICATIONS

Display:

3.5 digit, 0.5" (12mm) H LCD

Ranging:

Manual ranging

Polarity:

Automatic, minus (-) sign indicates negative polarity

Ranges and Accuracy:

DC Voltage:

200-2000mV-20-200-1000V

+/-0.5% of reading and +/-2 digits

(Maximum measurement = 1000V)

AC Voltage:

200-750V

+/-1.2% of reading and +/-10 digits

(Maximum measurement = 750V RMS)

DC Current:

200-2000

µ

A-20-200mA

+/-1.2% of reading and +/-2 digits

Summary of Contents for DMR-1100

Page 1: ...OWNER S MANUAL Digital Multimeter DMR 1100 CIRCUIT TEST ELECTRONICS LTD Burnaby BC Canada V5C 5Y1 www circuittest com...

Page 2: ...ery 4 Never connect unit to AC or DC powered circuits when function switch is set to diode check or continuity 5 To safeguard against electrical shock or damage to instrument never connect to more tha...

Page 3: ...ad the displayed voltage 1 5 If the minus sign appears the voltage is negative at the point being measured 2 AC VOLTAGE MEASUREMENT WARNING Maximum input is 750V AC RMS 2 1 Plug the red test lead into...

Page 4: ...switch to or from the 10A position first disconnect power and test leads from the circuit being tested Repeat the above steps using the correct input jack and range switch position 5 CONTINUITY TEST...

Page 5: ...eplace with a new 9V battery 7 4 Replace the cover and cover screws 8 FUSE REPLACEMENT WARNING Disconnect both test leads from any equipment before removing back cover Do not use the meter with the ca...

Page 6: ...MANUEL D UTILISATION Multimetre Digital DMR 1100 CIRCUIT TEST ELECTRONICS LTD Burnaby BC Canada V5C 5Y1 www circuittest com...

Page 7: ...rdons de l quipement avant d enlever la batterie 4 Ne branchez jamais l unit un circuit vivant AC ou DC quand le s lecteur de fonctions est diode ou continuit 5 Pourpr venirleschocs lectriquesoudommag...

Page 8: ...c t positif 1 4 Prenez la lecture de voltage 1 5 Si le signe moins apparait le voltage est n gatif au point mesur 2 MESURE DE VOLTAGE AC ATTENTION L entree maximale est 750V AC RMS 2 1 Branchez le co...

Page 9: ...rouge au c t positif du circuit de fa on telle que les cordons soient en s rie avec la charge mesurer 4 4 Appliquez l alimentation au circuit 4 5 Prenez votre lecture de courant NOTE Si vous changez l...

Page 10: ...ert 7 1 D branchez les cordons et teignez l appareil 7 2 Enlevez les vis du couvercle l arri re du boitier et enlevez le couvercle 7 3 D branchez la batterie et remplacez la par une batterie neuve de...

Reviews: