background image

 
Operating instructions 

 

1.  Connect the iron to the base station 

 
2.  Connect the power and switch on. The iron will heat. 
3.  Rotate the temperature adjustment dial on the front panel to adjust the 

temperature to the desired setting.  

 
Three Channel Storage Feature: 

 

The unit is equipped with the ability to store 3 separate heat settings. 
 
To Store Temperature Settings 

Press  the  CH1  button to  display  the 

  icon  on  the  control  panel.  Adjust 

the  main  dial  to  set  the  desired  temperature  on  the  display.  After  6 
seconds  at  the  set  temperature,  the  unit  automatically  stores  the 
temperature value to CH1. Set CH2 and CH3 in the same way to store 3 
quick access settings. 

 
Fahrenheit / Celsius Conversion: 

 

The user may choose to display either Celsius or Fahrenheit.  

  Press temperature dial until °C / °F icon flashes in the display.  

  Rotate  the  temperature  adjustment  dial  to  switch  between 

Fahrenheit  /  Celsius  (left  rotation  adjustment  for  °C,  right  rotation 
adjustment for °F).  

  After  setting,  the  characters  flash  seven  times  before  returning  to 

work  mode.  You  may  also  press  the  temperature  dial  again  to 
confirm your setting. 

 

Iron Sleep Function Settings: 

 

  Press the temperature dial twice, the display panel flashes L00. 

  Rotate  the  temperature  adjustment  dial  to  set  the  iron  sleep  time 

(Range: 0-99 minutes, 00 for no sleep). 

  The time set will flash 7 times before returning to work mode. You 

may  also  press  the  dial  again  to  confirm  your  setting  and  cycle 
through to set the automatic shutdown feature. 

 
NB.:  During  sleep  mode,  the  soldering  iron  temperature  is 
automatically  lowered  to  200°C.  Simply  move  the  iron  handle  to 
restore the settings that were active prior to sleep mode activation. 
 
 
 

 
 
 

5.  To Set the Automatic Shutdown Feature: 

 

 

Press the temperature dial 3 times until the display flashes “P00”.  

  Rotate  the  main  dial  to  set  automatic  shutdown  time  (range  0-99 

minutes, - set 00 to cancel automatic shutdown). 

  The  display  will  flash  seven  times  before  returning  to  work  mode. 

You may also press the main dial again to confirm your selection.   

 

6.  To Set the Temperature Correction Feature: 

 

Press the main dial 4 times. The display will flash “00”. 

  Rotate  the  main  dial  to  set  the  iron  temperature  (correction  range: 

±50°C).  

 

 

The display will flash seven times before returning to work mode. 
You may also press the main dial again to confirm your selection

 

 

NB:  The  CSI  PREMIER  75W  is  calibrated  at  the  factory.  For  most 
applications, there should be no requirement to re-calibrate the unit. This 
feature  should  only  be  required  if  the  user  wishes  to  re-calibrate  the 
output due to the use of a different tip style or operating environment, or if 
there is a discrepancy in output after heating element / iron replacement. 
 
 

 
 
Limited Warranty Statement 

This  unit  has  a  limited  warranty  of  1  year  from  the  date  of  the  original 
purchase receipt. Excluded from this warranty are any consumables such 
as soldering tips and heating elements. Should the main body fail during 
the warranty period, Circuit Specialists wil

l, at its’ option, repair or replace 

the  damaged  unit.  This  warranty  applies  only  to  manufacturing  defects. 
Damage caused by misuse, physical trauma etc. is excluded. To receive 
warranty service, the unit must be returned to the point of purchase. The 
end  user  will  be  responsible  for  the  shipping  costs  (if  any).  Circuit 
Specialists  will  be  responsible  for  the  cost  of  returning  the  repair  or 
replacement. Please check with the appropriate retailer for specific return 
procedures. 

 

Reviews: