10.7 "@H" Default RF transmit power setting
Changes
the current and default RF transmit power.
Specify the RF transmit power following
'@H'
with the ASCII code of two
characters.
The default setting is enabled when the power is turned on again.
Value: '1''0' : 10 mW
'0''5' : 5 mW
'0''1' : 1 mW
Example: Change the current and default RF transmit power to 5 mW.
Control command: @H05
Control response: *H05
10.8 "@U" UART bit rate setting
Sets the UART bit rate.
Specify the UART bit rate following
'@U'
with the ASCII code of two characters.
The default setting is 19.2 kbps. The default setting can be changed with the "@O" command.
Value: '9''6' : 9.6 kbps
'1''9' : 19.2 kbps
'3''8' : 38.4 kbps
Example: Change the UART bit rate to 9.6 kbps.
Control command: @U96
Control response: *U96
10.9 "@O" Default UART bit rate setting
Changes
the current and default UART bit rate.
Specify the UART bit rate following
'@O'
with the ASCII code of two characters.
The default setting is enabled when the power is turned on again.
Value: '9''6' : 9.6 kbps
'1''9' : 19.2 kbps
'3''8' : 38.4 kbps
Example: Change the current and default UART bit rate to 9.6 kbps.
Control command: @O96
Control response: *O96
Caution: The newly-set default UART bit rate is enabled just after the power is turned on again and
UART communication can not be established with the old UART bit rate anymore.