![CIRCUIT DESIGN STD-502-R Operation Manual Download Page 5](http://html1.mh-extra.com/html/circuit-design/std-502-r/std-502-r_operation-manual_2608060005.webp)
OPERATION GUIDE
.
OG_STD-502-R_v09e
Circuit Design, Inc.
5
Electrical specification (Receiver)
Item
Specification
MIN
TYP
MAX
Unit
Remarks
Reception method
Low IF
Maximum input level
-13
dBm
Receiver sensitivity
(BER, 9.6 kbps)
-20 to + 65°C /all channels
-93
dBm error rate = < 1 %
Receiver sensitivity
(BER, 19.2 kbps)
-20 to + 65°C /all channels
-93
dBm error rate = < 1 %
Blocking
EN300 440-1 compliant
-45
dBm
2 signal test, 1% error
Spurious radiation
(1st Lo)
dBm
Power on -> County code reception
42
ms
Power on in the RX mode
Command reception -> RX
5
ms
Frequency change
3
ms
Command reception -> RX
start
TX to RX
2
ms
Terminal input -> Stable
operation
Actuation
time
Recovery from standby
1.2
Standby -> RX start