Transmitter mode setting
An example of this setting is provided in the [Explanation for internal processes (4) (encoder)] application.
Set the transmit mode by setting the T/R terminal to [GND=TX].
Make the setting in accordance with the following procedure:
(1) Set all ports between CH0 and CH5 as shown in figure below.
(2) Switch on the power supply while pressing the setting switch.
(3) Release the setting switch.
(4) Commence the built-in micro-computer settings.
(5) The data volume (byte length) is automatically detected at the same time as the disconnection check
is run.
(6) The LD port will blink L and H in 0.3 second cycles if a disconnection is detected.
* Recheck the connections and perform the settings again.
(7) The LD port will blink L and H in one-second cycles if all is normal.
(8) The setting data will be transmitted. A time-out will occur after approximately ten seconds.
(9) After the receiver settings are complete, switch off and on the power supply to the transmitter once
again, then enter the communication mode.
Transmit mode setting
Execute mode setting
Power on
Release setting switch
Setting end
Transmit setting data
Y
N
LD blinks in 0.3 second cycles
Disconnection
Connection check
Error
LD blinks in 1-second cycles
Detect data length
Confirm receiver setting
Press setting switch
Disconnection
check