CIRCUIT DESIGN CDP-RX-02F-R Operation Manual Download Page 5

OPERATION GUIDE

.

OG_CDP-02F-R_v30e

Circuit Design, Inc.

5

CDP-RX-02F(P)-R Receiver

All ratings at 25°C +/- 5°C unless otherwise noted

Parameter

Rating

Conditions

General characteristics

Applicable standard

EN 300 220 –2

Communication method

One way

Emission class

F1D

Operating frequency range

433.1875 – 434.7750 MHz

Operating temperature range

-20 to + 60 °C

No dew condensation

Storage temperature range

-30 to + 70 °C

No dew condensation

Aging rate

Max. +/- 1 ppm / year

TX freq. / RX Local Freq.

Initial freq. tolerance

Max. +/- 2 ppm

At delivery *

1

Dimension

30 x 50 x 9 mm

Excluding protrusion

Weight

20 g

Not including the antenna

Electrical specification

Oscillation system

PLL controlled VCO

Channel spacing

25 kHz

Number of RF channels

128 ch (12.5 kHz step)

Default channel at delivery (434.775 MHz)

Data rate

300 to 4800 bps

(Pulse length Min. 208 us Max. 20 ms)

DI input level

L = Gnd H = 3V to Vcc

Data polarity

Positive

TX DI vs RX DO

PLL reference frequency

21.25 kHz

TCXO

Antenna impedance

50 ohm

Nominal

Operating voltage

3 – 12 V

Consumption current

Typ. 30 mA at 3 V

Typ. 33 mA at 12 V

Receiver electrical specification

Receiver type

Double superheterodyne PLL synthesizer

Bit error rate (0 error /2556 bits)

Typ. -116 dBm

At DO 4800 bps PN9 (-20°C to + 60°C)

Bit error rate (1% bit error)

Typ. -120 dBm

At DO 4800 bps PN9 (-20°C to + 60°C)

Sensitivity (12 dB / SINAD)

Typ. -120 dBm

fm1kHz, Dev.+/-2.0kHz, CCITT (-20 to + 60°C)

Frequency stability

Max. +/- 4 ppm

- 20 to 60°C with reference frequency at 25°C

Adjacent channel selectivity

60 dB

2 signal / 25 kHz / BER 1% / PN9 4800 bps

Blocking

84 dB

2 signal /Reference sensitivity:-120dBm / +/-2,
+/-10 MHz / BER 1% / PN9 4800 bps

Spurious radiation

- 60 dBm

Below 1 GHz

- 50 dBm

Above 1 GHz

Distortion

- 30 dB

1 kHz Dev =+/-2.0 kHz CCITT (RF level –30 dBm)

S/N ratio

35 dB

1 kHz Dev =+/-2.0 kHz CCITT (RF level –30 dBm)

RSSI

230 mV +/- 50 mV

At –113 dBm

AF output level

145 mV +/- 30 mV

fmod = +/-2.0 kHz fm = 1.2 kHz (RF level -30 dBm)

110 mV +/- 30 mV

fmod = +/-2.0 kHz fm = 2.4 kHz (RF level -30 dBm)

RSSI rising time

Typ. 20 ms / Max. 50 ms

Channel change (50 kHz) (-20°C to + 60°C)

Typ. 40 ms / Max. 70 ms

At power on (-20°C to + 60°C)

Time to valid Data out *

2

Typ. 50 ms / Max. 100 ms

Channel change (50 kHz) (-20°C to + 60°C)

Typ. 70 ms / Max. 140 ms

At power on (-20°C to + 60°C)

Specifications are subject to change without prior notice

*1 Initial frequency tolerance: At delivery
Initial frequency tolerance is defined as frequency drift within 1 year after the final adjustment

*2 Time to valid output signal:
Valid output signal is determined at the point where the Bit Error Rate meter starts detecting a 4800bps,
1010.. repeated signal.
The valid output signal varies with the temperature conditions. You must conduct field testing to verify the
waiting time for a valid output signal in the user system.

Summary of Contents for CDP-RX-02F-R

Page 1: ...band radio data module CDP TX RX 02F R 434 MHz Operation Guide Version 3 0 June 2017 CIRCUIT DESIGN INC 7557 1 Hotaka Azumino Nagano 399 8303 JAPAN Tel 81 0 263 82 1024 Fax 81 0 263 82 1016 e mail inf...

Page 2: ...NERAL DESCRIPTION FEATURES 3 SPECIFICATIONS 4 PIN DESCRIPTION 6 CHANNEL AND FREQUENCY SETTING 8 POWER SETTING 11 ANTENNAS 12 BLOCK DIAGRAM 13 DIMENSIONS 15 TEST DATA 17 REGULATORY COMPLIANCE INFORMATI...

Page 3: ...hannels externally There are no other technical and mechanical differences between CDP 02F R and CDP 02FP R General description The CDP TX 02F R and CDP RX 02F R are an RoHS compliant embedded industr...

Page 4: ...mpedance 50 ohm Nominal Operating voltage 3 12 V Consumption current Typ 43 mA At 10 mW 3 V Max 47 mA Typ 33 mA At 1 mW 3V Max 37 mA Transmitter part RF output power 10 mW 1mW Selectable Frequency sta...

Page 5: ...bit error Typ 120 dBm At DO 4800 bps PN9 20 C to 60 C Sensitivity 12 dB SINAD Typ 120 dBm fm1kHz Dev 2 0kHz CCITT 20 to 60 C Frequency stability Max 4 ppm 20 to 60 C with reference frequency at 25 C A...

Page 6: ...supply Connect it to the ground plane as well as to the bottom part of the case The ground plane has an impact on the range and the stability of operation VCC I The power supply terminal The supply vo...

Page 7: ...y of operation VCC I The power supply terminal The supply voltage is DC 3 0 to 12 V Power supply noise and ripple have an impact on performance so eliminate them as far as possible with filters and ca...

Page 8: ...ON ON ON 15 433 3750 OFF OFF OFF OFF ON ON ON 16 433 3875 ON ON ON ON OFF ON ON 17 433 4000 OFF ON ON ON OFF ON ON 18 433 4125 ON OFF ON ON OFF ON ON 19 433 4250 OFF OFF ON ON OFF ON ON 20 433 4375 O...

Page 9: ...3 9625 ON OFF OFF OFF OFF OFF ON 63 433 9750 OFF OFF OFF OFF OFF OFF ON 64 433 9875 ON ON ON ON ON ON OFF 65 434 0000 OFF ON ON ON ON ON OFF 66 434 0125 ON OFF ON ON ON ON OFF 67 434 0250 OFF OFF ON O...

Page 10: ...F 107 434 5250 OFF OFF ON OFF ON OFF OFF 108 434 5375 ON ON OFF OFF ON OFF OFF 109 434 5500 OFF ON OFF OFF ON OFF OFF 110 434 5625 ON OFF OFF OFF ON OFF OFF 111 434 5750 OFF OFF OFF OFF ON OFF OFF 112...

Page 11: ...ch ON L OFF H 10 mW Jumper ON Default 1 mW Jumper OFF Note The power level limit of the 434 MHz ISM band in Europe is defined as below Please choose the maximum power and duty cycle allowed by the reg...

Page 12: ...en here Notice For CDP TX 02F R and CDP TX 02FP R use the antenna provided Using other antennas may invalidate compliance with the regulatory standards Refer to the REGULATORY COMPLIANCE INFORMATION i...

Page 13: ...OPERATION GUIDE OG_CDP 02F R_v30e Circuit Design Inc 13 BLOCK DIAGRAM CDP TX 02F R...

Page 14: ...OPERATION GUIDE OG_CDP 02F R_v30e Circuit Design Inc 14 CDP RX 02F R...

Page 15: ...OPERATION GUIDE OG_CDP 02F R_v30e Circuit Design Inc 15 DIMENSIONS CDP TX 02F R Reference hole position for PCB mounting Top view...

Page 16: ...OPERATION GUIDE OG_CDP 02F R_v30e Circuit Design Inc 16 CDP RX 02F R Reference hole position for PCB mounting Top view...

Page 17: ..._CDP 02F R_v30e Circuit Design Inc 17 OPERATION GUIDE TEST DATA 0 100 200 300 400 500 600 700 800 130 120 110 100 90 80 70 60 50 40 30 20 10 0 R S S I m V INPUTLEVEL dBm RSSI characteristics MIN TYP M...

Page 18: ...using Circuit Design s standard antenna ANT LEA 01 1 4 lambda lead antenna so we recommend using the ANT LEA 01 antenna or an antenna with equivalent characteristics 2 14 dBi or less For details about...

Page 19: ...cuits and reverse connections may result in overheating and damage and must be avoided at all costs Ensure that the power supply has been switched off before attempting any wiring work The case is con...

Page 20: ...ar 2008 DOC updated Page 19 1 3 May 2008 Addition of note Page 18 1 4 Feb 2009 DOC updated Important notice added Page 19 20 1 5 Feb 2011 DOC updated Page 19 1 6 Feb 2014 DOC and TX block diagram upda...

Page 21: ...neath the radio module a ground pattern utilizing part of the shield If the power line and or the signal input line are long the printed line can be subject to high frequency noise This noise may caus...

Page 22: ...built for CDP TX 02E taking into consideration the above points is shown below Model No RPB T02N 1 Circuit Design Inc All rights reserved No part of this document may be copied or distributed in part...

Reviews: