![CIRCUIT DESIGN CDP-RX-02F-R Operation Manual Download Page 5](http://html1.mh-extra.com/html/circuit-design/cdp-rx-02f-r/cdp-rx-02f-r_operation-manual_2608039005.webp)
OPERATION GUIDE
.
OG_CDP-02F-R_v30e
Circuit Design, Inc.
5
CDP-RX-02F(P)-R Receiver
All ratings at 25°C +/- 5°C unless otherwise noted
Parameter
Rating
Conditions
General characteristics
Applicable standard
EN 300 220 –2
Communication method
One way
Emission class
F1D
Operating frequency range
433.1875 – 434.7750 MHz
Operating temperature range
-20 to + 60 °C
No dew condensation
Storage temperature range
-30 to + 70 °C
No dew condensation
Aging rate
Max. +/- 1 ppm / year
TX freq. / RX Local Freq.
Initial freq. tolerance
Max. +/- 2 ppm
At delivery *
1
Dimension
30 x 50 x 9 mm
Excluding protrusion
Weight
20 g
Not including the antenna
Electrical specification
Oscillation system
PLL controlled VCO
Channel spacing
25 kHz
Number of RF channels
128 ch (12.5 kHz step)
Default channel at delivery (434.775 MHz)
Data rate
300 to 4800 bps
(Pulse length Min. 208 us Max. 20 ms)
DI input level
L = Gnd H = 3V to Vcc
Data polarity
Positive
TX DI vs RX DO
PLL reference frequency
21.25 kHz
TCXO
Antenna impedance
50 ohm
Nominal
Operating voltage
3 – 12 V
Consumption current
Typ. 30 mA at 3 V
Typ. 33 mA at 12 V
Receiver electrical specification
Receiver type
Double superheterodyne PLL synthesizer
Bit error rate (0 error /2556 bits)
Typ. -116 dBm
At DO 4800 bps PN9 (-20°C to + 60°C)
Bit error rate (1% bit error)
Typ. -120 dBm
At DO 4800 bps PN9 (-20°C to + 60°C)
Sensitivity (12 dB / SINAD)
Typ. -120 dBm
fm1kHz, Dev.+/-2.0kHz, CCITT (-20 to + 60°C)
Frequency stability
Max. +/- 4 ppm
- 20 to 60°C with reference frequency at 25°C
Adjacent channel selectivity
60 dB
2 signal / 25 kHz / BER 1% / PN9 4800 bps
Blocking
84 dB
2 signal /Reference sensitivity:-120dBm / +/-2,
+/-10 MHz / BER 1% / PN9 4800 bps
Spurious radiation
- 60 dBm
Below 1 GHz
- 50 dBm
Above 1 GHz
Distortion
- 30 dB
1 kHz Dev =+/-2.0 kHz CCITT (RF level –30 dBm)
S/N ratio
35 dB
1 kHz Dev =+/-2.0 kHz CCITT (RF level –30 dBm)
RSSI
230 mV +/- 50 mV
At –113 dBm
AF output level
145 mV +/- 30 mV
fmod = +/-2.0 kHz fm = 1.2 kHz (RF level -30 dBm)
110 mV +/- 30 mV
fmod = +/-2.0 kHz fm = 2.4 kHz (RF level -30 dBm)
RSSI rising time
Typ. 20 ms / Max. 50 ms
Channel change (50 kHz) (-20°C to + 60°C)
Typ. 40 ms / Max. 70 ms
At power on (-20°C to + 60°C)
Time to valid Data out *
2
Typ. 50 ms / Max. 100 ms
Channel change (50 kHz) (-20°C to + 60°C)
Typ. 70 ms / Max. 140 ms
At power on (-20°C to + 60°C)
Specifications are subject to change without prior notice
*1 Initial frequency tolerance: At delivery
Initial frequency tolerance is defined as frequency drift within 1 year after the final adjustment
*2 Time to valid output signal:
Valid output signal is determined at the point where the Bit Error Rate meter starts detecting a 4800bps,
1010.. repeated signal.
The valid output signal varies with the temperature conditions. You must conduct field testing to verify the
waiting time for a valid output signal in the user system.