F. OPERATION

 

 

F.1 LIQUID 

LIMITATIONS

 

 

Never operate with thin liquids such as solvents or water.  The pump is designed for liquids 
having the general characteristics of oil.

 

 

F.2 OPERATING 

LIMITS

 

 

 

CAUTION

 

 

ATTENTION

   

Operating conditions, such as speed, fluid viscosity, temperature inlet pressure, discharge 
pressure, filtration, duty cycle, drive type, mounting, etc., are interrelated.  Due to these 
variable conditions, the specific application limits may be different from that of the 
operational limitations. This equipment must not be operated without verifying system’s 
operating requirements are within the pump’s capabilities.

 

 
Under no circumstances are the following operating limits (specified in Table 2) to 
be exceeded without specific approval from Imo Pump.

 

 

Table 2 – Normal Pump Operating and Structural Limits

 

 

MAXIMUM SPEED

 .............................................................. Rotor sizes 118 thru 156  4400 RPM Rotor 

size 187 thru 200  3600 RPM

 

VISCOSITY

 .................................... 45 SSU (5.8 cSt) Minimum – 3000 SSU (650 cSt) Maximum

 

 

NOTE:   

Consult factory for allowable operating viscosities at specific speeds and pressures.

 

DO NOT alter design viscosity without prior consultation with Imo Pump.  

MINIMUM – MAXIMUM LIQUID TEMPERATURE

 .............................. 0 to 250F (-18 to 121C) MAXIMUM 

INLET PRESSURE

 ......................................................................................... 200  psig

 

NOTE: 

Series 12L pumps are designed for positive inlet pressures.  The unit should not be 
operated for extended periods of time with inlet pressure less than atmospheric.

 

 

MAXIMUM DISCHARGE PRESSURE

 ............................. Rotor  Size  118, 4000 psig, Cont. Duty

 

Rotor Sizes 137 thru 200 4500 psig, Cont. Duty

 

 

NOTE:    Consult Imo Pump for 5000 psig operation

 

 

FILTRATION.

...................................................................(See Imo General Installation Operation, Maintenance, 

and Troubleshooting Manual, SRM00046)  

DRIVE

...........................................................................................................................Direct only ROTATION 

.................................................................................................Clockwise only facing pump shaft MOUNTING 
..............................................................................................................Foot or Flange mounted in any attitude 

 
 
 
 
 
 
 
 
 

Summary of Contents for IMO E12L Series

Page 1: ...on Maintenance and Troubleshooting Manual No SRM00046 along with this manual and all other component manuals supplied with these type units should be read thoroughly prior to pump installation start up operation maintenance or troubleshooting Manual No SRM00055 Rev 06 20 0051 February 2020 ...

Page 2: ...s can be done by removing seal vent set screw and pouring liquid into vent passageway before opening pump inlet Alternately seal chamber can be vented in situations where inlet pressure is above atmospheric by opening inlet and discharge valves and then loosening seal vent plug to allow positive inlet pressure to push air out of seal chamber until oil flows from it See figure below Filling or Vent...

Page 3: ...fect safety for persons Safety instructions where electrical safety is involved are identified by Safety instructions which shall be considered for reasons of safe operation of pump and or protection of pump itself are marked by the sign ATTENTION ATTENTION If operation of pump is critical to your business we strongly recommend you keep a spare pump or major repair kit in stock at all times As a m...

Page 4: ...by Imo Pump is to become part of processing machinery these instructions should be thoroughly reviewed to ensure proper fit of said equipment into overall plant operational procedures WARNING If installation operation and maintenance instructions are not correctly and strictly followed and observed injury to personnel or serious damage to pump could result Imo Pump cannot accept responsibility for...

Page 5: ... T Carbide Seal Seat F Foot Mounted E ORDERING INSTRUCTIONS When corresponding with Imo Pump regarding Series E12L pumps refer to the pump nameplate this instruction manual and the assembly drawing as instructed below 1 From pump nameplate record the pump model number serial number and manufactured date 2 Record instruction manual number revision and date 3 From the instruction manual record the f...

Page 6: ...rmal Pump Operating and Structural Limits MAXIMUM SPEED Rotor sizes 118 thru 156 4400 RPM Rotor size 187 thru 200 3600 RPM VISCOSITY 45 SSU 5 8 cSt Minimum 3000 SSU 650 cSt Maximum NOTE Consult factory for allowable operating viscosities at specific speeds and pressures DO NOT alter design viscosity without prior consultation with Imo Pump MINIMUM MAXIMUM LIQUID TEMPERATURE 0 to 250F 18 to 121C MA...

Page 7: ...Screw s SEE NOTE 65 1 Spacer 19 5 O ring s X 66 1 Truarc Ring XX 20 5 Plug s 66 2 Cap Screw s XX 21 1 Inlet Head 67 2 Idler Rotor s XX 22 1 Plug 70 1 O ring X 23 1 Power Rotor XX 71 1 Set Screw Cup 24 1 Seal X 72 3 Drive Screw s 25 1 Truarc Ring s X 74 1 LOCTITE X 27 1 Key 75 4 Idler Rotor s XX 28 1 Ball Bearing X Nameplate Module 29 1 Retainer X Minor Repair Kit Items XX Major Repair Kit Items It...

Page 8: ... service mechanical seal and ball bearings ONLY perform H 3 Steps 1 5 and H 4 Steps 3 4 7 and 8 ONLY H 4 Before starting pump disassembly perform the following a De energize driver b Close all inlet and outlet valves c Vent pressure from pump and drain pumping liquid d Remove cap screws and lock washers from inlet and outlet flange fittings e Remove any O rings from inlet and outlet flange grooves...

Page 9: ...1 Re move O rings 13 19 from grooves in case 1 H 7 Remove Idler Rotors and Bearing Retainer Remove idler rotors 67 75 33 from bores of rotor housings 3 4 by rotating power rotor in the opposite direction of normal rotation This will unscrew and release the idler rotors from the power rotor NOTE Do not permit the idler rotors to drop as they emerge from housing 3 Remove hex bolts 30 and bearing ret...

Page 10: ...ng 70 from groove of inboard cover 12 Remove O ring 7 and back up ring 66 from groove of inboard cover 12 b For rotor sizes 118 to 156 Remove Truarc ring 66 from groove of inboard cover 12 c For rotor sizes 187 and 200 Remove cap screws 66 from stop 17 d Remove stop 17 and balance piston bushing 15 from inboard cover 12 Remove O rings 19 from grooves of case 1 For rotor sizes 137 to 200 Remove spa...

Page 11: ...ug into bore in top of case 1 I 3 Assemble and Install Inboard Cover Discharge Side For Rotor sizes 137 to 200 Install spacer 16 in case 1 For rotor sizes 137 and 187 Install spacer 65 in case 1 Install back up ring 6 and O ring 7 in groove of inboard cover 12 Install balance piston bushing 15 and stop 17 on inboard cover 12 NOTE Back up ring should be installed toward inboard end discharge side o...

Page 12: ...er 12 I 5 Install Power Rotor Discharge Side Install power rotor 23 into inboard cover 12 and pump case 1 Center each part as it enters the inboard cover 12 Install retainer 29 and bolts 30 Torque bolts to 25 2 lb ft 33 9 2 7 Nm I 6 Install Idler Rotors Suction Side a Install idlers 33 75 and 67 into idler bores of housings 3 4 from outboard end of pump Mesh idlers with threads of power rotor and ...

Page 13: ...n Maintenance and Troubleshooting Manual No SRM00046 K FIELD AND FACTORY SERVICE AND PARTS Imo Pump maintains a staff of trained service personnel that can provide pump installation pump start up maintenance overhaul and troubleshooting supervision as well as installation and maintenance training Our factories provide maintenance as well as overhaul and test facilities in the event the user prefer...

Page 14: ...CAUTION ARROW TO LINE UP WITH EYEBOLTS FIGURE 3 PUMP ASSEMBLY ROTOR SIZE 118 Page 11 ...

Page 15: ...FIGURE 4 PUMP ASSEMBLY ROTOR SIZES 137 156 CAUTION ARROW TO LINE UP WITH EYEBOLTS Page 12 ...

Page 16: ...CAUTION ARROW TO LINE UP WITH EYEBOLTS FIGURE 5 PUMP ASSEMBLY ROTOR SIZES 187 200 Page 13 ...

Page 17: ...CIRCOR 1710 Airport Road PO Box 5020 Monroe NC USA 28111 5020 Tel 1 877 853 7867 Email cc circor com Web www circorpt com 2020 CIRCOR Pumps North America LLC All rights reserved ...

Reviews: