C.4  Qualifications of Personnel 
 

Only trained operators should be used for start-up and operation of the pump.  Only trained, specialized 
personnel should perform installation, maintenance, disassembly, or reassembly of the pump. 

 
C.5  General Safety Instructions 
 

o

 

Only trained operators or trained, specialized personnel may handle or operate the pump. 

 

o

 

Adhere to the operating limits provided in the Imo specifications or with the order documentation. 

 

o

 

Always wear proper personal protective equipment. (i.e. Safety glasses, steel-toed shoes, face 
shield, protective clothing, gloves, respirator, dust mask, etc., as required for safe practices) 

 

 

CAUTION

 

 

Do not run the pump dry, or with no inlet fluid flow.  Make sure the pump is only operated with, 
and never without, liquid filling the pump housing. 

 

 

DANGER

 

 

Do not remove safety guards or other protective devices prior to installation or during operation. 

 

C.6  Installation / Machine Specific Safety Instructions 

 

o

  Only use the pump as intended, while remaining aware of safety risks, and in adherence to the 

instructions in this manual. 
 

o

  Be certain all safety devices, machine safety guards, protective electrical connections, temperature 

monitoring devices, pressure monitoring devices and sealing apparatus are installed and operation prior 
to starting the pump.   

 

 

CAUTION

 

 

Do not operate the pump while the valves in the system are closed. 

 

o

  Pumps may not be used with foodstuffs, unless specifically adapted for that purpose.  Application for 

pumping foodstuffs must have been specified in the original purchase order. 
 

o

  In order to ensure normal functioning of the pump and system, monitor the pressure at the inlet and the 

outlet of the pump.  The monitoring locations should be in the inlet and outlet port connections / flanges, 
or immediately adjacent to those connections / flanges. 
 

o

  Monitor the pump temperature, after installation and during operation.  Note sudden changes in 

temperature which do not follow sudden changes in the temperature of the process liquid.  If sudden 
temperature changes of the pump occur, shut down the pump operation and contact trained, specialized 
personnel for inspection and maintenance.   

 

C.7  Safety Notes on Start-up 

 

o

  Check to insure that all process safety devices are in place and operational. 

 

o

  Be certain the pump is fully lubricated and full of fluid prior to starting the motor, and that fluid can and 

will freely flow into the inlet. 

 

o

  Be certain the pump temperature has fully reached the process temperature prior to starting the motor.  

Heat soak the pump sufficiently to ensure all recesses are at process temperature. 

 

Summary of Contents for 2BIC Series

Page 1: ...Safety and Operation WARNING These instructions should be read thoroughly by all personnel involved with pump operation prior to pump installation operation or maintenance Manual No SRM00100 Rev 02 1...

Page 2: ...Transportation of Pumps 10 D 2 Storage Spare Parts 10 E Installation Start up 11 E 1 General 11 E 2 Tools 11 E 3 Installation Preheating Start up 11 E 3 1 Lubrication Preparation 11 E 3 2 Preheating C...

Page 3: ...s Read observe and follow this manual and the other applicable documents especially all safety instructions and warnings A 2 Other Applicable Documents Document Purpose Product Service Manual Detailed...

Page 4: ...ntially Hazardous Situation Minor Bodily Harm Material Damage Symbol Meaning Safety Warning Take note of all information highlighted by a Safety Warning Sign and follow the instructions to avoid damag...

Page 5: ...flow with minimum fluid pulsation and low pump noise Fluid flowing through the pump provides lubrication for moving parts B 1 2 CIG General Description The CIG is a positive displacement internal gea...

Page 6: ...6 B 2 3 CIG Designation B 2 4 2BIC Designation B 3 Labeling B 3 1 CE Nameplate...

Page 7: ...al knowledge to apply generally accepted safety and operational practices which may not be otherwise covered Every effort was made to prepare the text of this manual so that technical information is c...

Page 8: ...ssure monitoring devices and sealing apparatus are installed and operation prior to starting the pump CAUTION Do not operate the pump while the valves in the system are closed o Pumps may not be used...

Page 9: ...valves can be opened or the blockage removed i NOTE Only trained specialized personnel are qualified to perform maintenance which includes but is not limited to o Inspection o Repair o Assembly o Disa...

Page 10: ...on from hot surfaces and hot liquids must be provided by the operator Take care not to drop the pump Pump weights are clearly and durably marked onto the pump surface Read and consider the weight prio...

Page 11: ...p housing WARNING On critical or dangerous equipment provide safety and emergency systems to protect personnel and property from injury due to pump malfunction If pumped liquids are flammable toxic co...

Page 12: ...other cool liquid to the surface If the pump is to be preheated or cooled prior to installation heat or cool the pump to the operating temperature by use of an approved method such as a band heater ba...

Page 13: ...are available Re adjust the packing follower several times through the running in period until the seal is thoroughly seated and the rate of leakage is stable F Operation Shutdown Restart F 1 Heating...

Page 14: ...ing power to driver Shut wire or chain and lock all valves in pump inlet outlet piping If applicable shut off any steam or other fluid supply lines to the pump Visually check equipment frequently for...

Page 15: ...Installation of spare parts should only be performed by trained specialized personnel in conjunction with the appropriate Original Installation Care and Maintenance Instructions H Failure All failures...

Page 16: ...2018 CIRCOR Pumps North America LLC All rights reserved CIRCOR 1710 Airport Road P O Box 5020 Monroe NC USA 28111 5020 Tel 704 289 6511 Website www circorpt com e mail cc circor com...

Reviews: