background image

 

 

 

 

 

Original Instructions 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Safety and Operation 
 

 
 

 

WARNING 

 

These instructions should be read thoroughly by all personnel involved with pump operation prior to pump 
installation, operation, or maintenance. 

 
 
 
 

Manual No. SRM00100 

Rev. 02 (19-0052) 

February 2019 

 

Summary of Contents for 2BIC Series

Page 1: ...Safety and Operation WARNING These instructions should be read thoroughly by all personnel involved with pump operation prior to pump installation operation or maintenance Manual No SRM00100 Rev 02 1...

Page 2: ...Transportation of Pumps 10 D 2 Storage Spare Parts 10 E Installation Start up 11 E 1 General 11 E 2 Tools 11 E 3 Installation Preheating Start up 11 E 3 1 Lubrication Preparation 11 E 3 2 Preheating C...

Page 3: ...s Read observe and follow this manual and the other applicable documents especially all safety instructions and warnings A 2 Other Applicable Documents Document Purpose Product Service Manual Detailed...

Page 4: ...ntially Hazardous Situation Minor Bodily Harm Material Damage Symbol Meaning Safety Warning Take note of all information highlighted by a Safety Warning Sign and follow the instructions to avoid damag...

Page 5: ...flow with minimum fluid pulsation and low pump noise Fluid flowing through the pump provides lubrication for moving parts B 1 2 CIG General Description The CIG is a positive displacement internal gea...

Page 6: ...6 B 2 3 CIG Designation B 2 4 2BIC Designation B 3 Labeling B 3 1 CE Nameplate...

Page 7: ...al knowledge to apply generally accepted safety and operational practices which may not be otherwise covered Every effort was made to prepare the text of this manual so that technical information is c...

Page 8: ...ssure monitoring devices and sealing apparatus are installed and operation prior to starting the pump CAUTION Do not operate the pump while the valves in the system are closed o Pumps may not be used...

Page 9: ...valves can be opened or the blockage removed i NOTE Only trained specialized personnel are qualified to perform maintenance which includes but is not limited to o Inspection o Repair o Assembly o Disa...

Page 10: ...on from hot surfaces and hot liquids must be provided by the operator Take care not to drop the pump Pump weights are clearly and durably marked onto the pump surface Read and consider the weight prio...

Page 11: ...p housing WARNING On critical or dangerous equipment provide safety and emergency systems to protect personnel and property from injury due to pump malfunction If pumped liquids are flammable toxic co...

Page 12: ...other cool liquid to the surface If the pump is to be preheated or cooled prior to installation heat or cool the pump to the operating temperature by use of an approved method such as a band heater ba...

Page 13: ...are available Re adjust the packing follower several times through the running in period until the seal is thoroughly seated and the rate of leakage is stable F Operation Shutdown Restart F 1 Heating...

Page 14: ...ing power to driver Shut wire or chain and lock all valves in pump inlet outlet piping If applicable shut off any steam or other fluid supply lines to the pump Visually check equipment frequently for...

Page 15: ...Installation of spare parts should only be performed by trained specialized personnel in conjunction with the appropriate Original Installation Care and Maintenance Instructions H Failure All failures...

Page 16: ...2018 CIRCOR Pumps North America LLC All rights reserved CIRCOR 1710 Airport Road P O Box 5020 Monroe NC USA 28111 5020 Tel 704 289 6511 Website www circorpt com e mail cc circor com...