background image

19

G

P OW E R   S U P P LY   L I N E 

C O N N E C T I O N

Perform the 230 VAC Single-phase or 400 VAC Three-phase connections as shown in 
the picture below.

Do not forget to connect the ground cable (PE) to its corresponding terminal.

N

SINGLE-PHASE CHARGE POINT

• 

Connect to the 

230V AC

.

THREE-PHASE Charge Point

• 

Connect to the 

400V AC

.

• 

If the Power Supply is Single-
Phase, connect L1 and N.

L1

 

L2

L3

N

P

E

Protections

Do not forget to connect the ground cable to the ground terminal

Make sure all screws are securely tightened at 1,5 Nm

Terminal block maximum cross-section: 10mm

2

S

Type of cable allowed by the terminal block: Copper

Cu

Protections

Summary of Contents for Wallbox eHome Series

Page 1: ...Installation Manual Wallbox eHome Series ...

Page 2: ...is manual can be reproduced copied translated or transmitted in any form or by any means without the prior written permission of the original manufacturer Information provided in this manual is intended to be accurate and reliable However the original manufacturer assumes no responsibility for its use or for any infringements upon the rights of third parties athat may result from its use All other...

Page 3: ...01 Here s your guide to install eHome So hello 02 Before the installation 04 Overview 06 Dimensions 08 Installation 10 Technical Data 26 Modbus Register Map 28 Need help 31 ...

Page 4: ...02 WallBox eHome Series Installation Manual 1 ...

Page 5: ...Y INFORMATION IN THIS DOCUMENT ELECTRIC RISK Take precautions to make the electrical connection inside the unit Unit must be disconnected from any power source during commissioning ATTENTION Indicates that the damage to property can occur if appropiate precautions are not taken Complies with IEC 61851 Electric vehicle conductive charging system IEC 61851 1 2017 and IEC 61851 21 2 2018 Complies wit...

Page 6: ...d CIRCONTROL will reject all responsibility and the warranty will be void Comply strictly with electrical safety regulations according to your country Do not make repairs or manipulations with the unit energised Only trained and qualified personnel should have access to low voltage electrical parts inside the unit Check the installation annually by qualified technician Remove from service any item...

Page 7: ...lectrical protections and the rest of the installation have to be aligned with the local and national rules The selectivity of the protections has to be guaranteed at all times 2 POWER SUPPLY LINE DIMENSIONING The dimensioning of the input power supply line of the charge point must be checked by a qualified electrician Note that various factors such as cable length between distribution board and c...

Page 8: ... the EV models of the market in MODE 3 according to European standard IEC 61851 1 by just connecting either its tethered cable with a Type 1 or Type 2 connector or connecting the EV cable into the charger socket Type 2 What s included The wallbox eHome Series can includes the RS 485 with interface Modbus in order to be managed by an external master device through it 3 Charge Point Installation Man...

Page 9: ...07 Overview 1 Circontrol Logo 2 Status RGB LED bar 3 Front cover 4 Cable Connector 5 Frame 6 Socket 7 Protections and Meter Door 1 3 2 6 5 7 4 ...

Page 10: ...08 WallBox eHome Series Installation Manual 4 Measures in mm 180 315 115 ...

Page 11: ...09 Dimensions 79 79 238 158 Measures in mm ...

Page 12: ...d The installation kit has been tested on a concrete wall For the unit to be securely fixed in such conditions it is recommended to use 3 x Inox A2 wall screws Ø3x45 3 x plastic anchors 6x40 If the installation surface has different properties the screws and plastic anchors must be defined by a qualified installer Screw driver Driller ...

Page 13: ...g the unit some space shall be reserved for usability maintenance and safety reasons Please comply accordingly to your country specifications The next picture shows the recommended minimum distances Measures in mm Front view 300 MIn 600 Max 1200 300 300 ...

Page 14: ...E UNIT 1 Remove the screw at the bottom of the box 2 Using a screw driver put it into the indicated marks at the bottom of the box and starting removing the frame doing click at the bottom Beware of not breaking the plastic of the frame with the screw driver ...

Page 15: ...ottom to the top 4 Remove the six screws of the front part by using a screw driver and take out the front part of the enclosure To make it easier help yourself with the screw driver while pulling the frame off Be sure that the unit is not energized before going forward with the opening procedure ...

Page 16: ...ertion opening at the bottom of the housing In all cases it is required to install a cable gland to ensure properly installation and preserve the IP of the unit 1 POWER SUPPLY LINE CABLE INSERTION OPENING Use a hammer and a flathead screwdriver carefully in order to break out the cable insertion opening as shown in the picture below 1 Cable insertion opening on the rear of the housing Breakable 2 ...

Page 17: ...NSERTION OPENING Introduce the cable through the opening and fix it properly by means of the supplied M25 cable gland Do not make any other holes on the enclosure Use only the named cable insertion opening to install the required electric pipes Install always either cable glands or double membrane seals to ensure IP protection of the charging point The data cable could be assimilated in the same e...

Page 18: ...k 3 holes taking into account the picture measurements also written on the rear face of the box 2 Place the enclosure on a flat surface 3 Use 3x45mm screws to fix the Charge Point to the wall 4 Check whether the box has any inclination using a level tool 5 Use Ø 6 drill size to make the 3 holes into the wall 6 Install the anchor according to the surface material ...

Page 19: ... the wall recommended screw dimensions 3x45mm 2 Use only the Charge Point holes indicated in the above picture to fix the Charge Point on the wall Do not make any other holes on the housing otherwise water can enter the Charge Point when it rains FIXING ...

Page 20: ...Current Device RCD externally to protecting the power line MCB RCD The Charge Point is set to 16A three phase 32A single phase from factory default settings On these series the Wallbox eHome Plus and Plus RS only could include electrical protections RCD in some configurations of the eHome Plus which are accesible for the electrical installer through a key safety door ...

Page 21: ...L N SINGLE PHASE CHARGE POINT Connect to the 230V AC THREE PHASE Charge Point Connect to the 400V AC If the Power Supply is Single Phase connect L1 and N L1 L2 L3 N PE Protections Do not forget to connect the ground cable to the ground terminal Make sure all screws are securely tightened at 1 5 Nm Terminal block maximum cross section 10mm2 S Type of cable allowed by the terminal block Copper Cu Pr...

Page 22: ... any tripping on the Main Circuit Please note that this accessory is only available for single phase Charge Points BeON is connected downstream of the main power switch and upstream of the main loads The BeON shall be connected to the port BOR1 on the PCB of the Charge Point For further information please refer to the Home BeON manual Signal cable has to be braided and to do two loops into the sna...

Page 23: ... jumper shall be removed to enable this function When the jumper is removed a device outside of the Charge Point can be placed to control the charge transaction This device should close the contact START to allow the charge transaction If the contact is open the charge transaction wont be able to start Do not remove the jumper if remote control function is not required otherwise the charge transac...

Page 24: ... Connection J Perform the Modbus RS485 data connection in the terminal shown in the picture below B A S Do not forget to connect the ground cable S Terminal and link to its corresponding earth terminal Notes The Modbus RS485 provide the following terminals A S B ...

Page 25: ...ure the limit current of the unit which has to be set up according to the model of Wallbox eHome Series dwe are going to install POSITION ELECTRIC CURRENT LIMIT 0 NOT USED 1 6 A 2 10 A 3 13A 4 16A 5 20 A 6 32 A 7 NOT USED 8 NOT USED 9 NOT USED Onthefollowingtableisshownthedifferentvaluesavailableforthiscurrentlimitselector ...

Page 26: ...o close the Charge Point Be aware of the cables between the cover and the base while closing the Charge Point Put the frame from the top to the bottom of the box ensuring it does click at the six points shown in the picture then screw de bold on the bottom Use an screwdriver while pulling the frame off to make it easier ...

Page 27: ...re starting the unit 4 ELECTRICAL PROTECTIONS If the unit includes electrical protections rearm all of them 5 CHECK THE BEACON INDICATORS All beacon indicators should light properly Here s the reference 6 OPERATION Check no abnormal noise appears while the unit is charging 7 PREVENTIVE MAINTENANCE It is recommended to perform one preventive maintenance per year VERIFICATION M PLUG STATE Available ...

Page 28: ... eHome T1C32 T2C32 T2S32 7 4 kW CCL eHome TRI T2S16 TRI T2C16 11 kW OUTPUT Charge system Mode 3 Connectors CCL eHome T1C32 Tethered cable Type 1 5m CCL eHome T2C32 TRI T2C16 Tethered cable Type 2 5m CCL eHome T2S32 TRI T2S16 Socket Type 2 Maximum output current CCL eHome T1C32 T2C32 T2S32 32 A CCL eHome TRI T2S16 TRI T2C16 16 A Maximum output power CCL eHome T1C32 T2C32 T2S32 7 4 kW CCL eHome TRI ...

Page 29: ...ing Net weight 4Kg Protections may not be included in the charge point at this point protections with the same characteristics shall be placed upstream The national regulations must be taken into account OPTIONAL FEATURES Extended operating temperature Optional Heater 30ºC 45ºC Protection shutter only available for Type 2 connectors RS485 Opcional Module ...

Page 30: ...x000C R 16bits ErrorCode 1 1 2 4 8 16 32 Error code 1 0x000F R 16bits MaxInPlug A Maximum Power Supply 0x0010 R W 16bits SetInMaxCharge A Set Maximum Power Supply 0x0014 R W 16bits Start 0 1 E V start charge process 0x0015 R W 16bits Stop 0 1 E V stop charge process always should be started by start register 0x0016 R W 16bits Pause 0 1 Temporary stop charge process 0x0017 R W 16bits DisablePlug 0 ...

Page 31: ...Mode Size Register Name Values Description BeOn 0x0032 R 16bits LineLoad_BeOn_AC 0x0033 R W 16bits TimerBeOn s Perormance Time Base Tick 0x0034 R W 16bits CurrentSlope_BeOn_AC 0x0035 R W 16bits SetPointBeOn_AC Device Identification 0x03E8 R 16bits HW FW version 0xHHSS HH Hardware version SS Software version 0x03E9 R 16bits Manufacturing number 20 bytes ASCII 0x03F3 R W 16bits Divice Name 20 bytes ...

Page 32: ...30 WallBox eHome Series Installation Manual 8 ...

Page 33: ...31 Need help In case of any query or need further information please contact our Post Sales Department 34 937 362 940 34 937 362 941 support circontrol com www circontrol com ...

Page 34: ...32 WallBox eHome Series Installation Manual 9 ...

Page 35: ...33 Notes ...

Page 36: ...tallation Manual CIRCONTROL WALLBOX eHome Series INSTALLATION MANUAL A comprehensive guide on how to install and verify your charge point V1 12 July 2021 Scan me to download the User Manual CIRCONTROLS A ALLRIGHTSRESERVED R381 ...

Reviews: