19
Technical Data
ELECTRICAL DATA
Power supply
1P+N+PE / 3P+N+PE
Input voltage
/- 10% / /-10%
Frequency
50Hz / 60Hz
Overcurrent protection
MCB (curve C)
Safety protection
RCD Type A (30mA) / Type B*
Surge protection*
Transient surge protector
IEC 61643-1 (Class II)
MODEL**
CONNECTORS
OUTPUT
CURRENT
OUTPUT
POWER
MINIMUM
CABLE CROSS-
-SECTION***
S
Type 2 Socket
Type 2 Socket
32A
32A
7,4kW
7,4kW
25mm
2
T
Type 2 Socket
Type 2 Socket
32A
32A
22kW
22kW
25mm
2
S-one
Type 2 Socket
32A
7,4kW
10mm
2
T-one
Type 2 Socket
32A
22kW
10mm
2
SM
Type 2 Socket
CEE 7/3
32A
16A
7,4kW
3,6kW
16mm
2
TM
Type 2 Socket
CEE 7/3
32A
16A
22kW
3,6kW
16mm
2
SM4
Type 2 Socket / CEE 7/3
Type 2 Socket / CEE 7/3
32A / 16A
32A / 16A
7,4kW / 3,6kW
7,4kW / 3,6kW
25mm
2
TM4
Type 2 Socket / CEE 7/3
Type 2 Socket / CEE 7/3
32A / 16A
32A / 16A
22kW / 3,6kW
22kW / 3,6kW
25mm
2
(*) Depending on the model, some components may vary
(**) For availability of models, please consult your local supplier
(***) This is the minimun cable section recommended for the maximum AC input current,
the final section must be calculated by a qualified technician taking into account the specific
conditions of installation