70
Raption 50 Series Instruction Manual
Value
Description
Use OCPP time synchronization
Yes:
Synchronization of date and time -> Enabled.
No:
Synchronization of date and time -> Disabled.
NOTE:
Date and Time is sent from backend on each
heartbeat response.
Compress OCPP messages
Yes:
Compress messages between Charge point and
backend -> Enabled.
No:
Compress messages between Charge point and
backend -> Disabled.
NOTE:
Before enabling this option consult to your
backend administrator if central system allows this
function.
Energy for Start/Stop
transaction
Partial:
Consumed value of energy by the vehicle sent
between start and stop.
Total:
actual count of the total accumulated energy
meter sent between start and stop.
Energy for MeterValues
Partial:
Sends partial energy consumption while vehicle
is charging.
Total:
sends the actual count of the total accumulated
energy meter.
Stop charge if StartTransaction
rejects the user
Yes:
Stop existing charge transaction after response
from backend (StartTransaction.conf) when user is
blocked, expired or Invalid.
No
: Charge transaction does not stops even if backend
rejects the user. (StartTransaction.conf)
NOTE:
Set this option according to your backend system.
Summary of Contents for CCS
Page 1: ...Instruction Manual Raption 50 Series ...
Page 2: ......
Page 4: ......
Page 10: ...06 Raption 50 Series Instruction Manual C Dimensions Units specified in millimeters ...
Page 39: ...35 3 CONNECTOR DISABLE 4 CONNECTOR IN USE ...
Page 40: ...36 Raption 50 Series Instruction Manual 5 CONNECTOR RESERVED 6 CONNECTOR BLOCKED PER RESERVED ...
Page 41: ...37 7 CONNECTOR BLOCKED PER CHARGING ...
Page 43: ...39 ...