background image

  Document: Service Manual 

Description: 

Elliptical/Upright Bike/ Recumbent Bike 

Model: 

E7/B8/R8, 

E Plus 

Page: 4 of 20 

 

4

 

1.3.

 

TV settings: CVBS 

1.3.1.

 

Scan Channel-Europe Tuner(Pal / DVB-T)

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 

Press Menu. 

Press Ch

 or Ch

 select 

Auto Tuning then press OK. 

Press Ch

 or Ch

or Vol+ or 

Vol- to select Country then 

press OK to starting channel 
scan. 

Channel scanning. 

Summary of Contents for R8

Page 1: ......

Page 2: ... 3 1 4 Preference Unit Max Level Page 4 1 5 System Page 5 1 5 1 State Used information 1 5 2 Calibration Current Torque setting 1 5 3 Settings other settings 1 5 3 1 Timezone Offset 1 5 3 2 Management Server Local Host IP 1 6 ErrorLog Page 5 1 7 Testing Page 6 1 8 Update 1 8 1 Update App software update Page 7 1 8 2 Update Bookmarks update website link Page 8 1 8 3 Replace Logo Replace Logo Page 1...

Page 3: ...bent Bike Model E7 B8 R8 E Plus Page 3 of 20 3 1 Engineering Mode Press center of logo for 5 seconds to get in 1 1 Wi Fi settings 1 2 Ethernet reserved for further use ON OFF Wi Fi Re searching Useable Wi Fi Select a Wi Fi and insert the pass code then press Connect ...

Page 4: ...nt Bike Model E7 B8 R8 E Plus Page 4 of 20 4 1 3 TV settings CVBS 1 3 1 Scan Channel Europe Tuner Pal DVB T Press Menu Press Ch or Ch select Auto Tuning then press OK Press Ch or Ch or Vol or Vol to select Country then press OK to starting channel scan Channel scanning ...

Page 5: ...otal Distance Total used distance Total Time Total used time Ave Speed Average Speed Settings Other settings Timezone Offset Timezone setting for USB data saving file name reference to date and time Management Server Asset Management Local Host IP Calibration parameter settings Current Torque Default setting Do not change Duty Increment Step Current output increment mA for each level increment ...

Page 6: ...ecords 1 7 Testing control system output test and input information OFF Stop resistance coil ON enable resistance coil Output current may be set from 0mA 3000mA Level 1 25 corresponds to 0mA 1500mA 1000mA recommended for testing purpose Error message Total used Time while error occur Total used distance while error occur Delete this record ...

Page 7: ...e 1 8 1 Update App Software update Step 1 insert the USB device shall be have new software inside e g Treadmill 20150126170001 signed apk to external USB port of machine Step 2 enter to engineering mode Update page select new software and press Update 1 2 3 System will back to idle main page after installing new software ...

Page 8: ... Recumbent Bike Model E7 B8 R8 E Plus Page 8 of 20 8 1 8 2 Update Bookmarks update internet website icon and address Step 1 To create a document name it to bookmark Step 2 Put website icon to bookmark document the icon specification shall be 152X152 PNG format ...

Page 9: ...Bike Model E7 B8 R8 E Plus Page 9 of 20 9 Step 3 Create a new note or WordPad file Typing the website information according to the rules as below Website name Website address Icon file name The last link information without a comma A comma to create next link information ...

Page 10: ...ion Elliptical Upright Bike Recumbent Bike Model E7 B8 R8 E Plus Page 10 of 20 10 Step 4 save the link information file to a UTF 8 format and change file name to bookmark change vice file name to Jason then put it to bookmark document ...

Page 11: ...ecumbent Bike Model E7 B8 R8 E Plus Page 11 of 20 11 Step 5 Put bookmark document to USB device insert the USB device to external USB Port of Machine Step 6 Enter to engineering mode Update page press Update key of Bookmarks will show update finished after update ...

Page 12: ...ht Bike Recumbent Bike Model E7 B8 R8 E Plus Page 12 of 20 12 1 8 3 Replace Logo Step 1 Logo icon size shall be under 330X80 with png format change icon name to logo then put into USB device root content Insert USB device to external USB port of machine ...

Page 13: ...re will be have 2 logos shown at engineering mode Update page one is current logo another is new logo in USB device press Update key that next to New Logo to replace the logo Press Configuration to exit engineering mode to main page to check the logo NOTE if you do not want to show any Logo just press Clear to clear logo 1 2 ...

Page 14: ...information Machine Type Upright bike or Elliptical depend on what software you installed Model type Machine Serial Number U for bike R for recumbent and E for elliptical APP Software Version Kernel Firmware version just need to check month date yea r Jan 19 2016 MFi Apple Device compatible version Console PCB assembly Serial Number ...

Page 15: ...rsion is 12 01 2014 want to update to Feb 11 2015 shall be use update_141201_150211_native zip Android version or update_141201_150211_logo zip Circle version update file 2 1 3 System read update zip file name only the update file name we provide with version information e g update_141201_150211_logo zip you need to change the file name to update zip before insert USB device to external USB port o...

Page 16: ...16 of 20 16 2 2 How to update copy update file update zip to USB device insert USB device to external USB port of machine system will auto update and reboot NOTE System will delete update zip of USB device if you would like to update next machine you need to copy the update zip file to USB device again ...

Page 17: ...hooting 3 1 Error Code PAUSE Description Console cannot read the rpm feedback signal due to no communication or no rpm feedback Troubleshooting chart In engineering mode Testing is it possible to ignore rpm feedback and apply pedal resistance directly Output current 1000mA is recommended No Yes Check rpm feedback sensor wire ...

Page 18: ...20 18 Flashing 3 times per second Replace EMS controller Flashing once per second Communications fail The root cause is a faulty console wire RJ 45 cable EMS controller or console PCB Verify the root cause by replacement Replace RJ 45 wire Replace EMS controller Replace console PCB Check LED on EMS controller ...

Page 19: ...B8 R8 E Plus Page 19 of 20 19 3 2 Symptom Console not switched on Yes Replace console PCB Remove the console plastic cover and check if 12DC input exists on console PCB or not No Check if 12DC output exists on EMS controller or not No Replace EMS controller Yes Replace 12DC power cord ...

Page 20: ...D on EMS controller Flashing 3 times per second UART ERR Communication abnormal Please restart to re establish communication If the led light is flashing 3 times per second it s abnormal Check if the console PCB Motor PCB or connection wires are normally Flashing once per second Machine is running normally Normal Status Stays on Machine is standby Normal Status ...

Reviews: