Engineer Manual-Trouble Shooting
VERSION
B
Step
illustrate
Auxiliary Photo
Do it can be calibrate normally or show LS
on TIME window?
7
If calibrate normally and return to idle
mode, please check the SPEED parameter on
CALORIES window when calibrate speed at
max speed 20km/h(±0.1).
In normal condition, the SPEED parameter
shall be between 340~350.
If calibrate abnormal, open motor cover
and check speed sensor connected well.
If speed sensor connected well, please
replace the sensor and check again.
Refer to 2.3『Speed Sensor』
If still show error signal, have to check
the console wire, damage or connect
terminal problem.
If console wire check ok, please replace
the console wire then back to execute step
2, check the error signal disappear or not.
Refer to 2.2『Console Wire』
8
If still show error signal after replace
the console wire, please replace the
console PCB then back to execute step 2,
check the error signal disappear or not.
Calibrate abnormal, show 【LS】
Calibrate normal, return to idle mode