background image

 

10

4. Operations 

Batteries must be fresh and properly loaded before start operation. 

4.1 Keypad 

operations 

The 8300 Series Terminals have two keyboard layouts: 24 rubber keys and 39 rubber keys. The 
functions of some special keys are as follows: 

 
SCAN 

 

        Scan a barcode

Press this button will trigger the scanner to read a barcode if the scanner port is 
enabled. 

 

 

 

 

 

ENTER                  Enter

There are two enter keys on the side of the scan key. Normally the enter keys are 
used for command execution or input confirmation. 
 

ESC

  

                

Escape

Usually this key is used to stop and exit current operation. 
 

BS   

                Back Space

.  

If this key is being pressed down longer than one second, a 

clear

 code will be 

sent. 
 

ALPHA / 

α

 

        The toggle key for Alphabet / Numeral input

When the system is in alpha-mode, a small icon will be shown on the display. For 
the 24-key keyboard, each numeral key can be used to generate one of the three 
capital letters. For example, numeral 

2

 can be used to produce 

A

B

 or 

C

. Pressing 

the same key twice within one second, will call the letter B. Pressing the same 
key without halting longer than one second, will cause the three letters to be 
shown in a circulating way. Only when stop pressing the key for longer than one 
second or pressing another key, will the system send the real key code to the 
application program. 

 

 

 

 

 

FN                   

 

The function key

.  

This key cannot be activated alone, it must be pressed with one numeral key at 
the same time. For example, 

FN

 + 

1

 generates function #

1

FN

 + 

2

 generates 

function #

2

, etc (up to 9 functions). Also, this key can be combined with the 

UP/DOWN

 arrow keys to adjust the contrast of the LCD. And when this key is 

combined with the 

ENTER

 key, it will turn ON/OFF the backlight. 

 

POWER  

 

Power On/Off

To prevent a faulty push, it needs about 1.5 sec continuous pressing to turn 
On/Off the power. 

 

4.2 Application 

mode 

This is the default operation mode when turning on the power. The operation depends on the 
application module. Please refer to section 4.4. 

Summary of Contents for 8300

Page 1: ... User s Guide Version 1 05 Copyright 2003 CIPHERLAB Co Ltd CIPHERLAB CO LTD Head Office 12F 333 Dunhua S Rd Sec 2 Taipei Taiwan Tel 886 2 8647 1166 Fax 886 2 8647 2255 e mail support cipherlab com tw http www cipherlab com tw ...

Page 2: ... 2 9 Indicator 3 2 10 Communication 3 2 11 RF Specification 3 2 12 Software 4 2 13 Accessories 4 3 Software Architecture 6 3 1 Kernel Application Manager 6 3 2 System 7 3 3 Application 9 3 4 Programming the terminal 9 3 5 Programming the communication cradle 9 4 Operations 10 4 1 Keypad operations 10 4 2 Application mode 10 4 3 System mode 11 4 4 Kernel mode 11 4 5 Application Manager 11 5 Trouble...

Page 3: ...crease the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help FCC Caution Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate this equipment Bluetooth ...

Page 4: ...ons RF model 194mm L x 77mm W x 44mm H Weight Batch model 230g including battery Weight RF model 250g including battery Housing color Black Housing material ABS 2 4 CPU Toshiba 16 bit CMOS type CPU Tunable clock up to 22MHz 2 5 Memory Program memory 1 M Bytes flash memory is used to store the program code font constant data and so on Data memory 2M 4M Bytes SRAM 2 6 Reader The 8300 Series Terminal...

Page 5: ...red LED for status indication 2 10 Communication RS 232 baud rate up to 115200 bps Serial IR baud rate up to 115200 bps Standard IrDA baud rate up to 115200 bps Bluetooth Class 2 data rate up to 433 Kbps IEEE 802 11b data rate up to 11 Mbps 2 11 RF Specification Bluetooth Class 2 Frequency Range 2 4000 2 4835 GHz Modulation GFSK Profiles BNEP SPP Data Rate 433 Kbps Coverage 10M line of sight Maxim...

Page 6: ... Programming Tools C compiler BASIC compiler and a Windows based Application Generator 2 13 Accessories Charging Communication cradle RS 232 cable Keyboard wedge cable Power adapter Li ion rechargeable battery pack 3560 Bluetooth Access Point 802 11b WLAN Access Point USB cable cradle Modem cradle ...

Page 7: ...5 ...

Page 8: ...e kernel menu if there is no application program exists then upon power up the terminal the following Application Manager s menu will be shown Download To download application programs SHX BASIC run time BC8300 SHX BASIC programs SYN or font files 8xxx XX SHX to the terminal There are 6 resident locations and one Active Memory i e at most 7 programs can be downloaded to the terminal But only the o...

Page 9: ...nd sixteenth speed Default Full speed 4 Auto Off Set time threshold for automatically power off when no operation is taking place during that specified period If this value is set to zero this function will be disabled Default 10 minutes 5 Power On Options There are two possible selections Program Resume which starts from the program being used during the last session before the last power off and...

Page 10: ...y To test the data memory SRAM Note after the test the contents of the memory space will be wiped out 4 Memory 1 Size Information Information includes sizes of the base memory SRAM memory card SRAM and program memory FLASH in the unit of kilobytes 2 Initialize To initialize the data memory SRAM Note the contents of the data space will be wiped out after memory initialization 5 Power Show the volta...

Page 11: ...l And for RF models you need to use the RF Database Manager to handle the in coming and out going data to and from the PC For detailed information please refer to 8300 Series Application Generator User s Guide and RF Application Generator User s Guide 3 4 Programming the terminal There are three software tools available for developing application programs for the terminal 1 The Application Generat...

Page 12: ...he three capital letters For example numeral 2 can be used to produce A B or C Pressing the same key twice within one second will call the letter B Pressing the same key without halting longer than one second will cause the three letters to be shown in a circulating way Only when stop pressing the key for longer than one second or pressing another key will the system send the real key code to the ...

Page 13: ...e refer to section 4 1 4 5 Application Manager Although the Application Manager is part of the kernel to enter it you need to press 8 and POWER key simultaneously Or if the application program does not exist the unit will automatically go to the Application Manager s menu upon power up The three services Download Activate and Upload provided by the Application Manager are explained in Section 4 1 ...

Page 14: ...top bit match with the Terminal s c Keypad does not work properly Turn off the power then press the 7 9 and POWER keys simultaneously to enter the system menu From the system menu select the Test and then its sub item KBD Perform the key in test If problem persists call for service d Scanner does not scan Check if the barcodes used are enabled or Check if battery low indicator is shown on the LCD ...

Reviews: