Cipax CPX Series Installation And User Manual Download Page 1

 

 

 

 

 

                

CPX sluten tank 1350L 

               CPX closed tank 1350L 

         

Installation och användarhandbok 

                   Installation and user manual 

                                 

Utgåva 1 

Edition 1 

 

   

 

 

 

 

 

 

 

 

 

 

 

www.cipax.se

 

 
 

 
 
 
 

 

 

Summary of Contents for CPX Series

Page 1: ...1 CPX sluten tank 1350L CPX closed tank 1350L Installation och anv ndarhandbok Installation and user manual Utg va 1 Edition 1 www cipax se...

Page 2: ...en det rotationsgjutet i polyetenplast Locket r testat och godk nt av SP enligt Boverkets handbok om Barns kra brunnar och SP metod 0487 genomtrampningsprov utg va 3 Installation av tanken kan ske b d...

Page 3: ...hals h jd 250 mm _______________________________________________________________________ F rh jningshals CPX art nr 450501 Fast hals h jd 400 mm ______________________________________________________...

Page 4: ...en tr dl sa s ndaren p h gsta l mpliga h jd och f sts med medf ljande skruv F r artikel 606171 borras ett 16 mm h l f r kabelgenomf ringen Grada h let Med en syl el liknande g rs ett h l i kabelgenomf...

Page 5: ...nt om s m ste detta simuleras vid installation ovan jord Till exempel mha en st dram Kontakta CIPAX f r mer info F rankring av tank Om minsta risk finns f r att grundvatten kan n upp till tanken b r t...

Page 6: ...h jder Tankarna b r ha ett avst nd p minst 500 mm f r att s kerst lla terfyllning om tankarna r nedgr vda Montering av f rh jningshals Samtliga f rh jningshalsar monteras p tanken p identiskt s tt 1 G...

Page 7: ..._____________________________________________________ T mning av tank Normalt ska t mning ske genom locket men om t mning nskas ske genom separat t mningsr r som d b r rekommenderas av ortens slamt mm...

Page 8: ...Se sista sidan f r ritning p tanken Volym 1350 L Vikt 85 kg inklusive lock Till tet installationsdjup max 2000 mm Till ten grundvattenniv max 675 mm fr n tankens botten Till ten belastning p lock och...

Page 9: ...thylene plastic The cover has been tested and approved by SP in accordance with the Swedish National Board of Housing s handbook for Childproof wells and SP method 0487 Trample Test version 3 The tank...

Page 10: ...eck height 250 mm _______________________________________________________________________ Extension neck CPX Part No 450501 Extension neck height 400 mm _______________________________________________...

Page 11: ...and attach with supplied screw For Part No 606171 Drill a 16 mm hole for the rubber grommet Deburr the hole With an e g awl make a small hole in center of the grommet and then pull through the cable _...

Page 12: ...tion height for waste removal vehicles for the areas prior to installation Securing of the tank If there is any risk the ground water level can reach up to the bottom of the tank the tank should then...

Page 13: ...rt side or long side of the tank that has connection planes at equal heights The distance between the tanks when buried should be at least 500 mm Mounting the extension neck All extension necks are at...

Page 14: ...fill in around the lower edge so that the tank is well supported Do NOT use a vibratory plate compactors when backfilling Emptying the tank The tank is normally emptied via the lid but if the tank is...

Page 15: ...awing of the tank at last page Volume 1350 L Weight 85 kg including lid Max permitted installation depth 2000 mm Max permitted ground water level 675 mm from the bottom of the tank Max permitted load...

Page 16: ...16...