Cipax CPX 23001 Installation Manual Download Page 4

4/10 

 

Attention! When the 23020 CPX Closed Tank 3000L is installed 
without  an  enhancement  neck  (installation  depth  <0.4  m),  the 
CPX Locking Ring 45020 accessory must be fitted to allow the 
lid to lock directly onto the tank.  
 
Anchoring 
If  groundwater  is  expected  to  reach  the  tank,  it  should  be  an-
chored to prevent it from floating upwards. Anchoring cloth or 
straps are recommended in combination with sufficient anchor-
ing  plates.  The  tank  can  be  subjected  to  large  forces,  so  make 
sure  that  the  cloth  or  strap  covers  a  large  area.  If  straps  are 
used,  they  should  be  age-resistant.  Ensure  that  there  are  no 
sharp edges on the strap locks against the tank.  
 
Connection 
The  tank  comes  with  a  Ø110  mm  rubber  inlet  prepared  on 
delivery.  More  connections  are  possible  on  both  the  long  and 
short sides.    
  
The  pipe  connection  from  the  property  to  the  sewage  tank 
should not have sharp bends. For example, use two 45° bends 
instead  of  one  90°  bend.  Inlet  pipes  should  be  at  frost-proof 
depth  and  inserted  at  least  200mm  into  the  tank.  Ensure  that 
connecting pipes have a level and stable surface to rest on be-
fore backfilling.  
  
Backfilling 
The backfill approx. 200 mm closest to the tank should consist 
of  draining gravel  or sand without sharp stones  that  can cause 
damage.  Take  particular  care  to  seal  well  around  the  bottom 
edge and in the through-holes so that the tank is well stabilised. 
Then  seal  the  fill  gradually  all  around.  Do  not  use  a  soil  com-
pactor when backfilling. 
  
Serial connection of tanks  
The pipe between the tanks should be Ø160 mm and should be 
connected  to  the  flat  surfaces.  The  pipe  should  be  inserted 
about 200 mm into the respective tank and can be connected 
both on the short sides and on the long sides which have con-
nection surfaces at the same heights. The tanks should be spaced 
at least 500 mm apart if they are buried. 
  
 

Ventilation 
The tank and its pipework must have good ventilation to func-
tion  properly.  Either  via  the  drain  with  venting  on  the  building 
roof  or  via  a  separate  ventilation  pipe  directly  on  the  tank.  In 
that  case  the  pipe  should  have  a  diameter  of  at  least  75  mm. 
When used for drainage, occasionally some odour may be pre-
sent. In this case, an activated carbon vent can be installed.  
 
Level alarm 
Battery-powered level alarm that indicates when the tank is full 
is available as an accessory. Including mounting kit and 10 m ca-
ble between sensor and control panel.  
  
Art. 606171 Level alarm with mounting kit 
  
The  level  sensor  (1)  is  mounted  on  the  edge  of  the  tank  as 
shown in the picture with the supplied screw, washer and nut. 
First drill an 8 mm mounting hole at approximately 90 degrees 
towards  the  incoming  drain  pipe.  The  alarm  is  activated  when 
approx. 300 L remain. If required, the hose clamp can be moved 
from the set position on the pipe to activate the alarm earlier or 
later.  
  
 
 
 
 
 
 
 
 
Drill a 16 mm hole for the cable entry. Burr the hole! Using an 
awl or similar, make a hole in the cable entry through which the 
cable is threaded. 
  
Emptying 
Normally,  emptying  should  be  through  the  lid,  but  if  another 
separate emptying pipe is used, a vent pipe of at least  
the same size must be fitted. Without a vent pipe, the tank is at 
risk of being compressed during emptying.  
  
Maintenance 
Although  the  tank  is  basically  maintenance-free,  it  may  still  be 
wise to check its function and status from time to time. A good 
time  is  after  each  emptying/filling.    Normally  it  is  sufficient  to 
check  that  no  object  is  blocking  any  functions.  Make  a  note  of 
the tank emptying date so that you can estimate when the next 
appointment is due.  

  

Art no 

Maximum installation depth  

23013 

2000 mm 

23020 

1950 mm 

23001 

1735 mm 

23031 

1919 mm 

23041 

2110 mm 

23060 

1950 mm 

Summary of Contents for CPX 23001

Page 1: ...l avplanad och v l dr nerad grus eller sandb dd utan vassa stenar eller liknande som kan skada tanken Se tabell nedan f r maximalt nedgr v ningsdjup Komprimera g rna grus sandb dden med markvibra tor...

Page 2: ...som har anslutningsplan p samma h jder Tankarna b r ha ett av st nd p minst 500 mm om tankarna r nedgr vda Ventilation Tanken med dess r rdragning m ste ha en bra ventilation f r att fungera tillfreds...

Page 3: ...ully for possible damage The tank is delivered standing on an EU pallet Lifting the tank The tank should be lifted with soft slings that can be threaded through the moulded lifting loops Only empty ta...

Page 4: ...tion surfaces at the same heights The tanks should be spaced at least 500 mm apart if they are buried Ventilation The tank and its pipework must have good ventilation to func tion properly Either via...

Page 5: ...rlag av grus eller sand som er minst 150 mm tykt godt planert og veldrenert uten spisse steiner eller lignende som kan skade tanken Se tabellen nedenfor for maksi mal nedgravningsdybde Komprimer gjern...

Page 6: ...er i samme h yder Tankene b r ha en avstand p minst 500 mm dersom de er gravd ned Ventilasjon Tanken og de tilh rende r rene m ha god ventilasjon for fungere tilfredsstillende Enten via avl pet med lu...

Page 7: ...ei ole ter vi kivi tai vastaavia jotka voivat vahingoittaa s ili t Katso alla olevasta taulukosta suurin mahdollinen hautaussyvyys Tiivist sora hiekkapohja mielell n maantiivist j ll Ennen asennusta...

Page 8: ...S ili iden et isyy den on oltava v hint n 500 mm jos s ili t on haudattu Ilmanvaihto S ili ss ja sen putkistossa on oltava hyv ilmanvaihto toimiak seen tyydytt v sti Joko viem rin kautta jossa on tuu...

Page 9: ...i liivapadjal milles ei oleks teravaid kive ega muud mis v iks mahutit kahjustada Maksimaalse s gavuse kohta vt tabelit allpool Tihendage kruusa liivapatja vibroplaadiga Enne paigaldamist Kanalisatsio...

Page 10: ...tel k lgedel mille henduskohad on samal k rgusel Ma hutite kaugus teineteisest maa sisse kaevatuna peab olema v he malt 500 mm Ventilatsioon Mahutil ja t mbetorudel peab olema hea ventilatsioon et k i...

Reviews: