Power
The Standard 410 unit is controlled by an internal power supply. 110 – 220VAC is provided to the unit via
a locking IEC connector, located on the back control panel.
NOTES:
1. Ensure the power cable is disconnected before servicing.
2. Do not connect to a variable supply, such as a dimmer rack.
3. The power cable should be plugged into the power supply before switching the power ON. The power
supply should be switched OFF before removing the power cable.
4. A fuse is located within the IEC connection port. A spare fuse is provided in this same space. If power
is provided, the power switch is ON and the LED light on the power switch is not illuminated, please
disconnect power and check this fuse first.
Displays Screens
The Standard 410 control interface includes two backlit displays, each of which communicates valuable
yet discrete information during the operation and setup of the Standard 410. They are separated as
CONTROL and STATUS.
Control Screen
The Control screen is an 8-character, daylight-visible
display that shows data adjustment values in Local
Mode, shows DMX signal status in DMX Mode,
Radio status, and interacts with the Status screen in
Menu Mode.
Status Screen
In Local Mode, the full-color screen displays the status
of each DIM, CCT, SATURATION and HUE control value.
The color ribbons on the top and bottom of the display
give a visual reference for both the CCT and the HUE.
DIM value and SATURATION are represented as a
percentage. In DMX mode, this display reflects the
current DMX channel assignment as well as the current
Personality and communication bitrate.