background image

10. Disposal 

11. Technical Information

 

Contents

Description

Rated voltage and frequency

Power consumption 

                       

 

 0.4 A

 

Battery / Life

Operation mode (Continuous operation)

    

Expression, Massage, Sync Mode

   

Suction levels 

                                    

 

Expression Mode

 

                                              

Massage Mode    

    

1 - 5 Levels

Cycle speeds

 

Fixed (24-35)

 

                                           

Massage Mode   

     

Fixed (52-93)

Single/Double

Timer function

Noise

Backflow protection 

                      

 

Yes

Cleaning Method for Accessories            

 

Boiling water

Operating conditions

Ambient temperature

Relative humidity 

Air pressure 

                              

 

700 to 1,060 hPa

Transport and storage conditions

Ambient temperature

Relative humidity 

Air pressure 

                                 

 

500 to 1,060 hPa

Protection on electronic shock

Degree of protection against ingress of water

   

IP Classification: IP22

Input: DC 5V, 2A

3.7V 2300mAh Li-Polymer / 2 hours + 

 

Class II,       TYPE BF Applied Part 

6 - 12 Levels

Single/Double

Automatic Off ( 30 min ± 1 min)

Less than 45 dB

Expression Mode

41 to 104°F

20 to 80 %

-4 to 122°F

20 to 95 %

Temperature

Humidity

Pressure

5

40

80

20

70

106

Temperature

Humidity

Pressure

-20

50

95

20

50

106

As an electrical and electronic equipment, the device must be 
disposed of according to a specialized procedure for collection, 
pick-up and recycling or destruction in accordance with Directive 
2012/19/EU of the European Council on Waste Electrical and 
Electronic Equipment [WEEE]. Please properly dispose the 
Class II medical device in accordance with local, state and federal 
regulations.

22

Summary of Contents for S5 Plus

Page 1: ......

Page 2: ...I store breast milk 8 2 How do I thaw and use stored milk 7 3 Determining the right fit 6 5 Pump Operation 6 6 Suction Settings 6 7 Massage and Expression Modes 5 Assembly 6 Pumping 7 Breast Shield Sizing 8 Breast Milk Storage 9 Troubleshooting 10 Disposal 11 Technical Information 12 Electromagnetic Compatibility 13 Description of IP Classification 14 Warranty Table of Contents 3 4 4 4 5 6 6 8 9 1...

Page 3: ......

Page 4: ......

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ... 12 11 10 9 13 15 Cimilre reserves the right to substitute any component or accessory with a replacement of equivalent performance 3 Components 9 2 Tubing 3 Backflow Protector Top 4 Backflow Protector Silicone 5 Backflow Protector Bottom 6 24mm 28mm Breast Shield 7 Valve 8 Bottle 9 Bottle Cap 10 Nipple 11 Bottle Cover 12 Bottle Disk 13 Air Flow Port ...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ... SELECT Button Select pumps 1 and 2 individually PUMP 1 Button Pause and restart pump 1 PUMP 2 Button Pause and restart pump 2 Power Button Suction Vacuum Level Expression Mode Sync Mode Massage Mode Massage mode symbol turns off when using expression mode Battery Status Timer Display 6 2 Button Controls ...

Page 13: ......

Page 14: ...er ON indicated by the screen lighting up and will be in SYNC mode 5 To adjust suction vacuum strength while in SYNC Mode use the level buttons to select preferred suction strength level Levels 1 5 Massage Mode Levels 6 12 Expression Mode When the pump is powered on for the first time after unboxing the suction may be preset to a higher level than desired Adjust the level to a preferred setting be...

Page 15: ...rred suction strength level Press SELECT again to adjust the suction strength level on the other side 8 At any time press the play pause button for pump 1 or 2 to pause and start pump operation 9 To return to using the same suction level for both sides press the SYNC button The SYNC light will appear in center of screen and the suction level will default to the lowest suction level set between the...

Page 16: ...ttings before you start expressing 2 The suction vacuum level refers to the suction strength this is measured in millimeters of mercury mmHg When you are using the Cimilre S5 Plus you will usually find that expressing is most effective on the highest suction level that is comfortable for you However it s important not to set suction level so high that it makes you uncomfortable or causes pain as t...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ......

Page 21: ...a Protection on electronic shock Degree of protection against ingress of water IP Classification IP22 Input DC 5V 2A 3 7V 2300mAh Li Polymer 2 hours Class II TYPE BF Applied Part 6 12 Levels Single Double Automatic Off 30 min 1 min Less than 45 dB Expression Mode 41 to 104 F 20 to 80 4 to 122 F 20 to 95 Temperature Humidity Pressure 5 40 80 20 70 106 Temperature Humidity Pressure 20 50 95 20 50 10...

Page 22: ......

Page 23: ......

Page 24: ......

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Page 29: ...REV 0 2 2022 03 04 UM 115 0 2 QF 708 22 ...

Reviews: